Configuration Option Tables
A-15
7610-A2-GB20-10
November 1997
Table A-5.
Management Port Options (3 of 3)
Stop Bits
Possible Settings: 1, 1.5, 2
Default Setting: 1
Provides the number of stop bits for the Management port.
Stop Bits option appears when Port Type is set to Asynchronous.
1, 1.5, or 2 – Selects the number of stop bits.
Monitor DTR
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies monitoring of the Data Terminal Ready (DTR) control lead.
Monitor DTR option appears when Port Type is set to Asynchronous.
Enable – Standard operation of the DTR control lead.
Disable – DTR is ignored. Some external device connections may require this setting.
Routing Information Protocol
Possible Settings: None, Proprietary
Default Setting: None
Specifies the routing protocol between devices through the Management port.
Routing Information Protocol appears when Port Use is set for Net Link.
None – No routing protocol; use None when the device connected to the Management
port is not a Model 7610.
Proprietary – Uses proprietary variant of RIP Version 1 to enable the routing of IP
traffic between Paradyne devices.
External Device Options for the Management Port
To access the External Device Options screen, follow this menu selection
sequence:
Main Menu
→
Configuration
→
Load Configuration From
→
Edit
→
User Interface
→
External Device