Testing
5-2
7510-A2-GB20-00
March 1997
Loopbacks can be started from a variety of points in the network, as shown in
Table 5-1.
Table 5-1.
Device Messages
Loopback Type
Initiated By
Notes
Bilateral Loopback
User
Remote unit sending
V.54 sequence
When enabled, running a DSU loopback
also automatically starts a local
loopback. Refer to
Data Port Options
,
Table A-3, to enable.
CSU Loopback
User (Network tests)
DDS Network, by
loop current reversal
When initiated by the network, CSU
Loopback cannot be disabled by the
user.
DSU Loopback
(Digital)
User
Refer to
Data Port Options
, Table A-3.
Local Loopback
User
DTE via CT141
Control via CT141 can be disabled.
Refer to
Data Port Options
, Table A-3.
Network-initiated
56 kbps DSU
Loopback (Non-
latching loopback)
DDS Network
Cannot be disabled by user.
Network-initiated
64 kbps CC DSU
Loopback
(Latching loopback)
DDS Network
Includes optional data scrambling and
uses 25-second timer to detect the
network sequence. Can be disabled by
user.
Remote Digital
Loopback
Remote unit sending
V.54 sequence
Same as a DSU Loopback but initiated
by a remote unit via V.54 sequence.
Can be disabled locally. Refer to
Network Interface Options
, Table A-2.
V.54 Sequences to
remote unit
User
DTE via CT140
Control via CT140 can be disabled.
Refer to
Data Port Options
, Table A-3.