background image

 9

7510-A2-GN10-30

January 1999

For Digital Data Service (DDS) installations, inform the local telephone company
of the appropriate facility interface code for the service you desire.

DDS Facility

Interface Code

Data Rate

04DU5-56

56 Kbps

04DU5-64

64 Kbps

The DDS Service Order Number is 6.0Y. The jack configuration required is
RJ48S. Refer to Appendix D, 

Technical Specifications, in the User’s Guide.

After the telephone company has installed the requested service and jack, you
can connect the DSU with the cable provided. An FCC-compliant telephone cord
and modular plug are provided with this equipment. This equipment is designed
to be connected to the telephone network or premises wiring using a compatible
modular jack that is Part 68 compliant.

Notice to Users of the Canadian Telephone Network

The Industry Canada label identifies certified equipment. This certification means
that the equipment meets telecommunications network protective, operational
and safety requirements as prescribed in the appropriate Terminal Equipment
Technical Requirements document(s). The Department does not guarantee the
equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The
equipment must also be installed using an acceptable method of connection. The
customer should be aware that compliance with the above conditions may not
prevent degradation of service in some situations.

Repairs to certified equipment should be coordinated by a representative
designated by the supplier. Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications
company cause to request to disconnect the equipment.

Users should ensure for their own protection that the electrical ground
connections of the power utility, telephone lines and internal metallic water pipe
system, if present, are connected together. This precaution may be particularly
important in rural areas.

CAUTION:

Users should not attempt to make such connections themselves, but
should contact the appropriate electric inspection authority, or
electrician, as appropriate.

The Ringer Equivalence Number (REN) assigned to each terminal device
provides an indication of the maximum number of terminals allowed to be
connected to a telephone interface. The termination on an interface may consist
of any combination of devices subject only to the requirement that the sum of the
Ringer Equivalence Numbers of all the devices does not exceed 5.

If your equipment is in need of repair, refer to the procedures described in the
next section.

Содержание 7510

Страница 1: ...727 2396 Outside the U S A call 1 727 530 8623 Cables You May Need to Order The following table describes typical equipment Identify the connectors required for your equipment before you contact your...

Страница 2: ...ng terminal emulation software Before installing your DSU read the Important Safety Instructions on page 7 Installing the DSU Procedure To install the DSU 1 Plug the end of the power cord into the POW...

Страница 3: ...nicate at a rate of 9 6 kbps using characters of 8 bits one stop bit and no parity If you connect an external modem instead of an asynchronous terminal or PC Use an EIA 232 crossover cable as describe...

Страница 4: ...D T R 1 0 8 System Network Port 497 15245 7510 DSU 56 64K Verify that the User Interface Idle screen is displayed on the terminal or PC Press the Enter key Verify that the Main Menu appears main Devic...

Страница 5: ...rfaces Configuration Display and edit the configuration options Control Establish identification for the DSU and system or to initiate a power up reset of the DSU Configuration Edit Display System Net...

Страница 6: ...ck 64K CC Enable Disable Data Scrambling 64K CC Enable Disable V 54 Initiated DSU Loopback Enable Disable Data Port Configuration Option Settings Default in Bold Invert Transmit Clock Enable Disable P...

Страница 7: ...7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a certif...

Страница 8: ...toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be inclu...

Страница 9: ...e connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with th...

Страница 10: ...documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com...

Отзывы: