 3

7510-A2-GN10-30

January 1999

497-15240

RJ48S

Jack

NETWORK

TERMINAL

POWER

D
T
E

DTE

Terminal

Connection

Power

Connection

 Network

Connection

 DTE

Connection

NOTES:

Your terminal or PC software must be set to communicate at a rate of 
9.6 kbps, using characters of 8 bits, one stop bit, and no parity.

If you connect an external modem instead of an asynchronous terminal or
PC:

— Use an EIA-232 crossover cable as described in Appendix C, 

Cables and

Pin Assignments, in the User’s Guide.

— If possible, configure your modem to use standard RS232 detection and

control for CTS, DSR, DTR, LSD, and RTS.

— If possible, disable AT commands on your modem.

Содержание 7510

Страница 1: ...727 2396 Outside the U S A call 1 727 530 8623 Cables You May Need to Order The following table describes typical equipment Identify the connectors required for your equipment before you contact your...

Страница 2: ...ng terminal emulation software Before installing your DSU read the Important Safety Instructions on page 7 Installing the DSU Procedure To install the DSU 1 Plug the end of the power cord into the POW...

Страница 3: ...nicate at a rate of 9 6 kbps using characters of 8 bits one stop bit and no parity If you connect an external modem instead of an asynchronous terminal or PC Use an EIA 232 crossover cable as describe...

Страница 4: ...D T R 1 0 8 System Network Port 497 15245 7510 DSU 56 64K Verify that the User Interface Idle screen is displayed on the terminal or PC Press the Enter key Verify that the Main Menu appears main Devic...

Страница 5: ...rfaces Configuration Display and edit the configuration options Control Establish identification for the DSU and system or to initiate a power up reset of the DSU Configuration Edit Display System Net...

Страница 6: ...ck 64K CC Enable Disable Data Scrambling 64K CC Enable Disable V 54 Initiated DSU Loopback Enable Disable Data Port Configuration Option Settings Default in Bold Invert Transmit Clock Enable Disable P...

Страница 7: ...7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a certif...

Страница 8: ...toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be inclu...

Страница 9: ...e connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with th...

Страница 10: ...documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com...

Отзывы: