background image

IPD4-A2-GZ40-10

July 2005

3

9. Upon such termination, the Licensee shall refrain from any further use of the 

Software and destroy the original and all copies of the Software in the 
possession of Licensee together with all documentation and related materials.

10. This Agreement shall be governed by the laws of the State of Florida, without 

regard to its provisions concerning conflicts of laws.

Introduction

Paradyne's 4000E IP Broadband Loop Carrier (BLC) provides a high capacity and 
native IP Ethernet foundation for a variety of feature-rich multi-service access 
mulitplexer modules.

The 4000E BLC features a high capacity backplane delivering up to 8 Gbps 
throughput, and providing a non-blocking architecture for even the highest 
bandwidth broadband access technologies, such as ADSL2+. It supports a single 
uplink, management, and switching module connected to the dual backplanes with 
redundant modular backhaul/uplink ports to support 10/100 Ethernet, GigE 
(copper or fiber), T1/E1, and dual bonded T1/E1 uplink modules. 

The 4000E BLC is environmentally hardened for installation in Remote Terminals 
or street cabinets. For flexibility of installation the 4000E BLC has removable 
mounting brackets that can be placed in increments of 1.45” up to 9.28” from the 
front of the chassis, allowing for multiple installation options in either 19" or 23" 
equipment racks.  

Unpacking and Inspecting the Equipment

HANDLING PRECAUTIONS FOR 
STATIC-SENSITIVE DEVICES

This product is designed to protect sensitive components from damage 
due to electrostatic discharge (ESD) during normal operation. When 
performing installation procedures, however, take proper static control 
precautions to prevent damage to equipment. If you are not sure of the 
proper static control precautions, contact your nearest sales or service 
representative.

The following components should be included in the shipping container:

„

1 – 4000E BLC with 1 fan module and 12 slot covers

„

4 – Rubber Bumper Screws

!

Содержание 4000E

Страница 1: ...eement The terms and conditions of this License Agreement the Agreement will apply to the software and or firmware individually or collectively the Software incorporated into the Paradyne product the Product purchased by you and any ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS YOU MAY USE THE SOFTWARE AND OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT BY USING THE PARADYNE ...

Страница 2: ...purchased by you THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED OR ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION a Any warranty that the Software is error free will operate uninterrupted in your operating environment or is compatible with any equipment or software configurations and b ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES O...

Страница 3: ...planes with redundant modular backhaul uplink ports to support 10 100 Ethernet GigE copper or fiber T1 E1 and dual bonded T1 E1 uplink modules The 4000E BLC is environmentally hardened for installation in Remote Terminals or street cabinets For flexibility of installation the 4000E BLC has removable mounting brackets that can be placed in increments of 1 45 up to 9 28 from the front of the chassis...

Страница 4: ...ere admittance is limited to trained and authorized service personel It may be installed on a tabletop or in a rack Installation on a Tabletop Insert the four provided rubber bumper screws into the mounting holes at the bottom of the 4000E chassis for surface grip and airflow Position and secure all connecting cables such that they will not become a tripping hazard or pull loose from the chassis E...

Страница 5: ...ition them as best suited to the space available for your chassis on the rack being utilized Mount the chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of eight 8 rack screws whichever size fits the rack being utilized Check the rack for stability ensuring that installation of the 4000E has not caused the rack to become top heavy ...

Страница 6: ...ort of the management module if redundancy is desired Refer to your management module or uplink module installation instructions for further information CAUTION If a slot cover is removed from a management module uplink port it must be replaced with an uplink module DO NOT OPERATE A 4000E WITH A MANAGEMENT MODULE THAT HAS AN OPEN UPLINK PORT Procedure 1 Identify the appropriate slot for installati...

Страница 7: ...models available for purchase Refer to www paradyne com for further information or contact your sales representative Any combination of interface module models may be installed in an 4000E as long as they are supported by the model type and version number of your management module refer to the Release Notes for your particular management module model CAUTION If a slot cover is removed from slots 2...

Страница 8: ...module guides With the interface module PCB facing up and the interface module model name on the right side of the module faceplate facing towards you align the left and right edges of the PCB with the slot module guides of the chosen slot on the 4000E 3 Slide the interface module fFirmly into the chassis Tighten the fastening screws on the interface module faceplate Slot Module Guides INTERFACE M...

Страница 9: ... Ground Wire to a Frame Ground Ground wire connection can vary from location to location although typically all equipment in a Central Office is grounded to a common copper bus 3 Select a Terminal Block Either terminal block on the back of the 4000E may be used to power the chassis only one terminal block is required for operational purposes The two terminal blocks on the 4000E are independent fee...

Страница 10: ... screw from the chosen terminal block labeled on the chassis Slide the ring terminal of your positive power lead around the shaft of the screw and insert the screw into the same terminal from which it was removed DC Terminal Blocks Ring Terminal POSITIVE POWER LEAD DC POWER TERMINAL Positive Terminal ...

Страница 11: ...s connected to the 4000E must be equipped with a disconnect device such as an On Off switch Otherwise an appropriately rated circuit breaker must be installed on each power circuit to be used In the case of an emergency hazardous voltages will not be removed from the 4000E until all power sources have been either turned off or disconnected from the chassis 7 Turn your power source s on The PWR pow...

Страница 12: ...stallation instructions for your particular interface module s The 4000E chassis supports ADSL IDSL SDSL and T1 E1 technologies Ensure that the subscriber lines you are connecting correspond with the technology of the interface module s installed in your 4000E Procedure 1 Identify the appropriate RJ21 Connector Subscriber lines must be connected according to the 4000E slot in which the correspondi...

Страница 13: ...pen leaving it looped under the right side of the connector frame 3 Slide the male RJ21 connector of your interface cable underneath the hook and loop fastener from the left and press it firmly into the female RJ21 connector port on the chassis 4000E REAR VIEW Interface Module B connectors Subscriber connections for ports 25 48 on applicable models Interface Module A Connectors Subscriber connecti...

Страница 14: ...RJ21 connector frame on the chassis Note If you are using a 120 or 180 degree cable both the right and left sides of the cable connector should be screwed to the RJ21 connector frame on the chassis The LK Link LED for each port being connected with a remote modem will illuminate solid or flashing green to indicate a connection has been established Link up time between interface modules and remote ...

Страница 15: ...ation Document Contents Management module installation instructions model specific module installation port pinouts parameter defaults parameter configuration options management system capabilities Uplink module installation instructions model specific module installation port pinouts parameter defaults parameter configuration options Interface module user guides model specific module installation...

Страница 16: ...ctionality is indicated by a FAN LED on your management module all models No illumination or solid GREEN illumination indicates all fans are currently functioning solid AMBER illumination indicates at least one of the four fans is no longer functioning CAUTION Do not operate the 4000E without a fan module or with a fan module that is not functioning properly 4000E FRONT VIEW Fan Module MANAGEMENT ...

Страница 17: ...e 40 F to 149 F 40 C to 65 C Storage Temperature 40 F to 158 F 40 C to 70 C Humidity 5 to 95 non condensing Altitude 200 ft to 16 500 ft 60 m to 5 000 m Physical 7 High x 17 Wide x 18 Deep 17 8 cm High x 43 2 cm Wide x 46 cm Deep 28 lbs 12 73 kg Power 48 VDC 10 amps maximum Although actual power draw depends upon chassis configuration a fully loaded chassis averages around 6 amps Regulatory Compli...

Страница 18: ...nded supply conductor Over current protection must be included with a 48 VDC 10 A fuse or circuit breaker in the ungrounded conductor Use minimum 16 AWG 2 5 mm2 fixed power source wires with strain retention 8 Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord 9 Slots and openings in the cabinet are provided for ventilation To en...

Страница 19: ...ser transceiver and for insuring that the Class 1 AEL Allowable Emission Limit per EN IEC 60825 is not exceeded after the laser transponders have been installed Do not install laser products whose class rating is greater than 1 Refer to all important safety instructions that accompanied the transceiver prior to installation Only laser Class 1 devices certified for use in the country of installatio...

Страница 20: ...ny help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current i...