background image

 16

CE Marking

Models 3172-A1-410 and 3174-A1-410 of this product are marked with the CE mark.
This mark has been affixed to demonstrate full compliance with the following European
Directives:

Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization
of the laws of the member states relating to electrical equipment designed for use
within certain voltage limits, as amended by Directive 93/68/EEC.

Directive 89/336/EEC – Council Directive of 3 May 1989 on the approximation of
the laws of the member states relating to Electro-Magnetic Compatibility (EMC), as
amended by Directive 93/68/EEC.

Directive 91/263/EEC – Council Directive of 29 April 1991 on the approximation of
the laws of the member states concerning telecommunication terminal equipment,
including the mutual recognition of their conformity, as amended by Directive
93/68/EEC. The application of this directive is in relation only to network connection
via the 120-ohm G.703 interface as specified in CTR12.

Содержание 3170

Страница 1: ...ACCULINK 3170 E1 DSU CSU QUICK REFERENCE Document No 3170 A2 GL10 00...

Страница 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Страница 3: ...aintain competitive prices for our products Complete documentation for this product is available at www paradyne com Select Service Support Technical Manuals T1 E1 Digital Access Devices Select the fo...

Страница 4: ...pment via the DTE and port connectors 3 If you intend to use front panel emulation connect the cable from the PC to the COM port on the rear panel of the DSU CSU 4 Power on the DSU CSU to perform the...

Страница 5: ...en using the 120 ohm interface POWER AUX PORT COM PORT DTE PORT 3 PORT 4 PORT 1 PORT 2 CLOCK IN 120 75 75 120 RX SHIELD OPEN EARTH RX 75 TX NETWORK CAUTION AUX PORT OR COM PORT MUST NOT BE CONNECTED T...

Страница 6: ...LED DL DTE Prt1 Prt2 Prt3 Prt4 PLB DLB RLB LLB Abort DCLB DTLB Abort Send Mon QRSS 1in8 511 QRSS 511 NET Prt1 Prt2 Prt3 Prt4 Far Near Prtn NET Far Near Cur 8Tot Intvl Cur 24Tot Intvl DCLB UP DCLB DN E...

Страница 7: ...nes Enab Sends all ones on channels allocated to the network E1 on Send Ones Disab Sends all ones on channels allocated to the network E1 on LOS LOF or AIS Table 2 Port Configuration Options 1 of 2 Op...

Страница 8: ...ase inversion of the transmit clock TXC InvertData Enab Allows the data on the port to be inverted InvertData Disab Allows the data on the port to be inverted EDL Enab Specifies whether the Embedded D...

Страница 9: ...ons Option Factory Comments Description DTE Channels TS16 Selects TS16 for signaling or assigns DS0 channels on the DTE DTE Channels Assign assigns DS0 channels on the DTE Drop Insert interface to DS0...

Страница 10: ...168 256 224 320 280 384 336 448 392 512 448 576 504 640 560 704 616 768 672 832 728 896 784 960 840 1024 896 1088 952 1152 1008 1216 1064 1280 1120 1344 1176 1408 1232 1472 1288 1536 1344 1600 1400 1...

Страница 11: ...assigns port 1 2 3 or 4 to that channel If assigned to DTE N1 N2 N31 unassigns port 1 2 3 or 4 to that channel NOTE Configuration options in this table are made available after Prtn where n is 1 or 2...

Страница 12: ...nternal or external Com Clk Ext Controls whether the COM ort uses an internal or external clock 1 2 2 4 Com Rate 4 8 Com Rate Communication Port 9 6 Selects the bit rate for the COM port Rate 14 4 19...

Страница 13: ...Trap Disab Sends SNMP traps Table 9 General SNMP Configuration Options 1 of 2 Option Factory Comments Description System Name Edit The SNMP system name for this device System Name Clear The SNMP syste...

Страница 14: ...t is Com IP Adr Clear The IP address for the COM ort when the COM ort is configured for SNMP Com NetMask Edit The Subnet Mask needed to access the device when the Com NetMask Clear The Subnet Mask nee...

Страница 15: ...anager n FDL g EDLn Disab Gen Trap Warm Specifies the general trap types to enable WarmStart Gen Trap Auth S ecifies the general tra ty es to enable WarmStart Authentication Failure or both Both Entp...

Страница 16: ...personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the cu...

Страница 17: ...C rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate...

Страница 18: ...ded by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the member states relating to Electro Magnetic Compatibility EMC as amended by Direc...

Отзывы: