Configuration Options
C-13
3166-A2-GB20-20
March 1999
Table C-4.
User Interface Configuration Options (4 of 6)
ComDisconnect:
Next Edit Clear Prev
Carrier Communication Port Disconnect String. Specifies the communication port’s
disconnect string. The communication port’s disconnect string is sent to the external
device if either you or the DSU/CSU wants to command the external device to
disconnect. The external device must be in command mode before this command can
be sent, so the escape sequence will always be sent before the disconnect string. The
disconnect string is an ASCII text string and may be up to 20 characters in length. If the
disconnect string is NULL, then no disconnect string is sent out.
Edit – Allows you to edit and/or display the disconnect string using the generic text
string entry screen.
Clear – Allows you to clear the disconnect string. The disconnect string is set to a null
string.
NOTE:
This configuration option is not available if the ComExtDev configuration
option is set to AT or the communication port is disabled.
Com Rate: 9.6
Next 1.2 2.4 4.8 9.6 14.4 19.2 Prev
Communication Port Rate. Configures the bit rate for the communication port.
1.2 – Sets the bit rate to 1200 bps.
2.4 – Sets the bit rate to 2400 bps.
4.8 – Sets the bit rate to 4800 bps.
9.6 – Sets the bit rate to 9600 bps.
14.4 – Sets the bit rate to 14,400 bps.
19.2 – Sets the bit rate to 19,200 bps.
Char Length: 8
Next 7 8 Prev
Communication Port Character Length. Configures the character length (7 or 8 bits) for
the communication port.
NOTES: – This configuration option must be set to 8 if the communication port is
used as the network communication link.
CParity: None
Next None Even Odd Prev
Communication Port Parity. Configures the parity (none, even, or odd) for the
communication port.
NOTE:
This configuration option is not available if the communication port is
configured for synchronous operation.
CStop Bits: 1
Next 1 1.5 2 Prev
Communication Port Stop Bits. Configures the number of stop bits (1, 1.5, or 2) for the
communication port.
NOTE:
This configuration option is not available if the communication port is
configured for synchronous operation.
Содержание 3166 DSU
Страница 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Страница 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 190: ...Asynchronous Terminal Interface Operation H 14 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Страница 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...