background image

Pin Assignments

 D-8

3166-A2-GB20-20

March 1999

EIA-530-A-to-X.21 Adapter

The EIA-530-A-to-X.21 adapter (Figure D-5) provides the X.21 interface shown in
Table D-5.

2

14

3

16

17

9

4

19

8

10

7

24

11

2

9

4

11

6

13

3

10

5

12

8

7

14

TD-A

TD-B

RD-A

RD-B

RXC-A

RXC-B

RTS-A

RTS-B

RLSD-A

RLSD-B

SIG. COMMON

TT-A

TT-B

TD-A

TD-B

RD-A

RD-B

RXC-A

RXC-B

RTS-A

RTS-B

RLSD-A

RLSD-B

SIG. COMMON

TT-A

TT-B

530

 SIGNAL

DB25
PLUG

DB15

SOCKET

X.21 
SIGNAL

495-14787

Figure D-5.

EIA-530-A-to-X.21 Adapter

Table D-5.

X.21 Cable Interface

 

Signal

CCITT Number

Direction

Pin

Signal Common

102

8

Transmitted Data

103

To DSU/CSU

2 (A)
9 (B)

Received Data

104

From
DSU/CSU

4 (A)
11 (B)

Request-to-Send

105

To DSU/CSU

3 (A)
10 (B)

Data Channel Received
Line Signal Detector

109

From
DSU/CSU

5 (A)
12 (B)

Transmit Signal Element
Timing (DTE Source)

113

To DSU/CSU

7 (A)
14 (B)

Receiver Signal Element
Timing (DCE Source)

115

From
DSU/CSU

6 (A)
13 (B)

Содержание 3166 CSU

Страница 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...

Страница 2: ...sued as a new release to this manual Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For addi...

Страница 3: ...ant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 8 Input power to the ac voltage configuration of this product...

Страница 4: ...ful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference a...

Страница 5: ...m to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will n...

Страница 6: ...ative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request to disconnect the equi...

Страница 7: ...uct Related Documents viii Reference Documents ix 1 Introduction Overview 1 1 Features 1 1 Alarm Message Capability 1 2 Front Panel Emulation 1 2 Asynchronous Terminal Interface ATI Support 1 2 Telnet...

Страница 8: ...r Protocol 3 23 Specifying the Community Name s and Access Type s 3 25 Configuring SNMP Traps 3 27 Enabling SNMP Trap Messages 3 27 Selecting the Number of Trap Managers 3 28 Configuring a Destination...

Страница 9: ...ne Loopback Up or Down 4 17 Sending a V 54 ANSI FT1 Activation Deactivation 4 18 Local Loopback Tests 4 19 Starting a Line Loopback 4 20 Starting a Payload Loopback 4 21 Starting a Repeater Loopback 4...

Страница 10: ...ions C 7 General Configuration Options C 9 User Interface Configuration Options C 10 Alarm Configuration Options C 16 Management Configuration Options C 19 D Pin Assignments Overview D 1 T1 Network In...

Страница 11: ...actional Group DS1 E1 MIB E 15 RS 232 like MIB RFC 1317 E 15 General Port Table RS 232 like MIB E 15 Asynchronous Port Table RS 232 like MIB E 16 Synchronous Port Table RS 232 like MIB E 17 Input Sign...

Страница 12: ...1 Resetting the ATI H 1 Initiating an ATI Session H 2 Ending an ATI Session H 2 Menu Organization H 3 Using ATI Screens H 4 Setting Customer Identification H 6 Displaying LED Conditions H 7 Changing C...

Страница 13: ...er 2 Installation Explains how to install the DSU CSU Chapter 3 SDCP Operation Explains the use of the optional Shared Diagnostic Control Panel SDCP including using the SDCP to configure SNMP paramete...

Страница 14: ...of the Asynchronous Terminal Interface ATI Appendix I Equipment List Lists feature numbers for equipment related to the DSU CSU Glossary Explains terms and abbreviations used in the text Index Lists m...

Страница 15: ...ustry Canada ICES 003 FCC Part 15 FCC Part 68 UL 1950 Management Information Base for Network Management of TCP IP Based Internets MIBII RFC 1213 March 1991 Definitions of Managed Objects for the DS1...

Страница 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 17: ...rier refer to the COMSPHERE 3000 Series Carrier Installation Manual Features The DSU CSU optimizes network performance with a wide range of features such as the following H Software configuration menu...

Страница 18: ...16 character LCD Telnet Access Remote asynchronous terminal operations can be performed using Telnet access Telnet is a Transmission Control Protocol Internet Protocol TCP IP service that supports a...

Страница 19: ...RT Select In Out Net Mon Rear Connector Module Circuit Card and Front Panel 98 16076 Table 1 1 3166 DSU CSU Rear Connector Module Connectors Name Function NET Network interface Provides access to the...

Страница 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 21: ...nstructions at the beginning of this guide HANDLING PRECAUTIONS FOR STATIC SENSITIVE DEVICES This product is designed to protect sensitive components from damage due to electrostatic discharge ESD dur...

Страница 22: ...connector module uses the same slot position intended for the DSU NOTE If an auxiliary backplane for Models 3151 or 3161 DSUs is installed in the same carrier verify that it is mounted over Slots 9 16...

Страница 23: ...ts faceplate in the open position Then insert the circuit card into the top and bottom circuit card guides for the slot that contains the rear connector module 5 Slide the DSU CSU into the slot aligni...

Страница 24: ...ndix D Pin Assignments for detailed cable and connector information Connect the other end to a terminal or PC Terminal or PC PORT 1 COM 98 16079 8 Attach the DB25 port cable to the PORT 1 connector on...

Страница 25: ...ert the other end into either DIAGNOSTIC CHANNEL connector of a neighboring 3166 rear connector module or the diagnostic channel connector of a T1 auxiliary backplane 98 16080 PORT 1 PORT 1 PORT 1 POR...

Страница 26: ...During the power up self test the Fail LED flashes then all LEDs blink twice When the test is complete verify that the DSU CSU is functional by observing that the OK and NET Sig LEDs are lit 98 16081...

Страница 27: ...scription of the SDCP and sample procedures for configuring the DSU CSU For more information about the SDCP refer to the COMSPHERE 3000 Series Carrier Installation Manual Using the SDCP The SDCP Figur...

Страница 28: ...s configuration options and test results In most cases the top line shows the command or option name and default value while the second line displays options and responses When a response is required...

Страница 29: ...olls one character to the left while the key scrolls one character to the right For menu screens the key scrolls to the previous menu choice while the key scrolls to the next menu choice F1 F2 F3 If a...

Страница 30: ...3 Table 3 1 System LEDs Name Color Meaning OK Select Green Indicates the current operational state of the DSU CSU ON The DSU CSU is operational and has power OFF The DSU CSU is performing a power up...

Страница 31: ...gnal ON At least one OOF was detected on the signal during the sampling period OFF No OOFs were detected on the signal during the sampling period Alrm Yellow Indicates whether an alarm condition exist...

Страница 32: ...F Zeros are being received from the synchronous data DTE CYCLING Both ones and zeros are being received from the synchronous data DTE RXD Green Monitors activity on interchange circuit BB CCITT 104 Re...

Страница 33: ...P Menu The customer identification is the only identity number you can change Procedure To display the DSU CSU s identity ID 1 From the top level menu screen select Stat F1 x yy DSU ESF Stat Test Cnfi...

Страница 34: ...SDCP Operation 3 8 3166 A2 GB20 20 March 1999 F1 Identity Cust ID xxxxxxxx F2 F3 F1 Identity SRev xx xx xx F2 F3 F1 Identity CCA1 xxxx xxx F2 F3...

Страница 35: ...trl 3 From the Control screen press the key until the CID selection appears on the screen 4 Select CID F1 Control Reset CID Passwd F2 F3 5 Use the and keys to position the cursor under the desired cha...

Страница 36: ...ay LED conditions on the front panel screen 1 From the top level menu screen select Stat 2 From the Status screen press the key until the LED selection appears on the screen 3 From the Status screen s...

Страница 37: ...y areas H Active Activ This is the configuration option set currently active for the DSU CSU Before a configuration option set becomes active for the DSU CSU you must save the set to the Active area W...

Страница 38: ...ttings These settings are based on the following Factory 1 ESF framing format with B8ZS line coding format for the network interface Data ports are unassigned Factory 2 D4 framing format with AMI line...

Страница 39: ...the configuration option set to be copied into the Edit area by using the appropriate Function key Use the scroll keys if necessary F1 Load from Activ Cust1 F2 F3 3 Select Edit F1 Choose Funct Edit Sa...

Страница 40: ...on Line 1 with the current value next to it To reach other options use the Next and Previous selections to scroll forward and backward through the group of options F1 NET Framing ESF Next D4 ESF F2 F3...

Страница 41: ...for future use NOTE If you attempt to exit the Edit function after making changes without performing a Save the DSU CSU prompts you with Save Options Choose Yes or No Procedure To save edit changes 1...

Страница 42: ...nfiguration options can be selected Procedure To enable the COM port 1 From the top level menu screen select Cnfig 2 Select the configuration option set to be copied into the Edit area by using the ap...

Страница 43: ...onfigured as the IP Bus Master If configured for either ASCII or Mgmt the carrier COM port may be configured to control an external device e g modem x 25 PAD through the use of AT or user specified co...

Страница 44: ...f ACK 0x06 G or g BEL 0x07 H or h BS 0x08 I or i HT 0x09 J or j LF or NL 0x0A K or k VT 0x0B L or l FF or NP 0x0C M or m CR 0x0D N or n SO 0x0E O or o SI 0x0F P or p DLE 0x10 Q or q DC1 0x11 R or r D...

Страница 45: ...otocol IP address and subnet mask needed to access the DSU CSU see Appendix F IP Network Addressing Scenarios Select the link layer protocol PPP or SLIP for the port that provides the link to the SNMP...

Страница 46: ...link to the SNMP or Telnet system Procedure To select the COM port as the SNMP or Telnet link 1 From the top level menu screen select Cnfig 2 Select the configuration option set to be copied into the...

Страница 47: ...ess of 010 155 111 222 is being set for the COM port You can use the same principles to assign any value between 000 and 255 for each digit field Procedure To assign an IP address to the COM port 1 Fr...

Страница 48: ...keys to position the cursor under the digit you want to change Press F1 Up to increment the digit or F2 Down to decrement the digit In this example you would press once to place the cursor under the m...

Страница 49: ...rived from the unit serial number and the elapsed time H Full negotiation of escape characters The Model 3166 DSU CSU implementation of PPP does not support Link Quality Reports LQR compression encryp...

Страница 50: ...1999 5 Select Mgmt F1 Edit User Alarm Mgmt F2 F3 6 From the Mgmt Config screen select Gen F1 Mgmt Config Gen Trap F2 F3 7 Press F1 Next until the Com Link configuration option appears 8 Press F2 PPP o...

Страница 51: ...el menu screen select Cnfig 2 Select the configuration option set to be copied into the Edit area by using the appropriate Function key Use the scroll keys if necessary 3 Select Edit 4 From the Edit s...

Страница 52: ...The erases all characters to the right of the cursor 10 When you are through changing the community name you must press F3 Save to save the value Otherwise the original value will be retained 11 Pres...

Страница 53: ...of traps to be sent from this DSU CSU For more information refer to Appendix C Configuration Options and SNMP Traps in Chapter 4 Monitoring and Testing Enabling SNMP Trap Messages Procedure To enable...

Страница 54: ...select Cnfig 2 Select the configuration option set to be copied into the Edit area by using the appropriate Function key Use the scroll keys if necessary 3 Select Edit 4 From the Edit screen press the...

Страница 55: ...sary 3 Select Edit 4 From the Edit screen press the key until the Mgmt selection appears on the screen 5 Select Mgmt F1 Edit User Alarm Mgmt F2 F3 6 From the Mgmt Config screen select Trap F1 Mgmt Con...

Страница 56: ...s channels to be assigned by specifying a data port rate and an initial DS0 channel the first DS0 channel in a block of DS0 channels However with ACAMI the number of channels assigned is twice the num...

Страница 57: ...ion key Use the scroll keys if necessary 3 Select Edit 4 Select Chan F1 Edit DTE NET Chan Gen F2 F3 5 From the Channel Config screen press the key to scroll the ports onto the screen 6 Select Prt1 F1...

Страница 58: ...ACAMI F2 F3 or F1 Assign By Next Block ACAMI F2 F3 2 Press F1 Next to display the next configuration option Port Rate 3 Use the or key to scroll the desired port rate onto the screen Rates scroll in...

Страница 59: ...bandwidth based on the configured data rate to be used as a starting channel number are displayed Channel allocation for this port can only be cleared by selecting Clear F1 Start At Clear Next Clear...

Страница 60: ...ssigned to other ports has no effect F1 N1 N2 Next Prt1 Prt1 F2 F3 Clearing DS0 Channel Allocation You can clear deallocate all the DS0 channels currently allocated to either the network interface or...

Страница 61: ...lock source configuration options enable you to select either the network interface a synchronous data port or the internal clock Configuring for Network Timing Procedure To configure for network timi...

Страница 62: ...wing section Setting a Password Procedure To establish access security on a port 1 From the top level menu screen select Cnfig 2 Select the configuration option set to be copied into the Edit area by...

Страница 63: ...2 Select Ctrl 3 From the Control screen press the key until the Passwd selection appears on the screen 4 Select Passwd F1 Control Reset CID Passwd F2 F3 5 Use the and keys to position the cursor under...

Страница 64: ...irst appears The following screen appears when you access a DSU CSU that has a password enabled F1 Passwd _ Up Down Done F2 F3 Procedure To enter a password 1 Use the and keys to position the cursor u...

Страница 65: ...broken This includes the termination of the front panel emulation program on a locally attached PC if the PC supports DTR or the termination of the Asynchronous Terminal Interface on a remote or loca...

Страница 66: ...elease the current active user interface either allow five minutes to elapse without pressing any key or use the Release command Procedure To use the Release command 1 From the top level menu screen p...

Страница 67: ...until the Ctrl selection appears on the screen 2 Select Ctrl 3 From the Control screen press the key until the Reset selection appears on the screen 4 Select Reset F1 Control ClrReg Reset F2 F3 5 Fro...

Страница 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 69: ...r network Self Test Health Use the Self Test Health command to display the results of the power up self test Possible messages are listed in Table 4 1 See Chapter 2 Installation for more information a...

Страница 70: ...rnal device level testing B8ZS LOS fail The unit failed to encode data properly or to detect Loss Of Signal Alarm fail The unit failed to transmit AIS or to detect an Yellow alarm Memory fail The unit...

Страница 71: ...r on Line 2 of the LCD in priority order highest to lowest The DSU CSU is polled for current status every ten seconds If the status has changed from the last poll the Health and Status screen is updat...

Страница 72: ...synchronous data port s Embedded Data Link EDL is enabled EER at Prt1 The error rate of the received signal has exceeded the configured threshold for data port Port1 This condition only occurs if the...

Страница 73: ...n valid data is also kept as well as a 24 hour total for each accumulator register Port performance is continuously monitored and maintained in memory registers when the port is configured to use EDL...

Страница 74: ...ent 15 minute interval appear F1 User Current Event xx xxx F2 F3 6 When you press F2 from the User Registers screen the User registers for the 24 hour total interval appear F1 User 24 Hour VldIntvl xx...

Страница 75: ...The maximum is 900 seconds This register is valid for the current interval only N A VldIntvl N A Valid interval total Records the number of valid 15 minute intervals in the previous x hours where x is...

Страница 76: ...errored second is any second with more than one but less than 320 CRC errors The maximum is 900 seconds The total number of bursty errored seconds for the previous x hours where x is 24 hours for aggr...

Страница 77: ...op Insert DSX 1 interface E The Excessive Error Rate threshold has been exceeded F A Frame Synchronization Bit Error has been detected If none of these events occurred during the interval StEvnt none...

Страница 78: ...lect Ctrl 3 From the Control screen press the key until the ClrReg selection appears on the screen 4 Select ClrReg F1 Control Rel LED ClrReg F2 F3 5 From the Clear Prf Regs screen press F1 to clear th...

Страница 79: ...e Network Interface Alarm Cleared Loss Of Signal condition at the Network Interface Continuous Out Of Frame condition detected at the Network Interface Alarm Cleared Out Of Frame condition at the Netw...

Страница 80: ...re to receive traps from this DSU CSU an IP address for each SNMP manager specified and the type of traps to be sent from this DSU CSU For more information refer to Appendix C Configuration Options an...

Страница 81: ...viceFail 3 An internal DSU CSU failure is detected by the operating software enterpriseTestStart 5 A test is initiated enterpriseConfigChange 6 A configuration option is changed enterpriseTestClear 10...

Страница 82: ...far end 3 Facility problem 1 Check that the network cable is securely attached at both ends 2 Check the far end status 3 Contact your facility provider Message OOF at Net appears 1 Incompatible frami...

Страница 83: ...atched 2 Start the link layer protocol Test Jacks Two test jacks are located on the front panel Net Mon Network Monitor In and Net Mon Out Net Mon In nonintrusively monitors the signal going into the...

Страница 84: ...nce for 10 seconds LLBDN For Channels V 54 activation sequence to initiate a V 54 Loop 2 54UP V 54 deactivation sequence to terminate a V 54 Loop 54DN ANSI T1 403 Annex B activation sequence to initia...

Страница 85: ...F2 F3 3 From the Rem Loopback screen press F1 to select LLBUP Line Loopback Up or press F2 to select LLBDN Line Loopback Down F1 Rem Loopback LLBUP LLBDN 54UP F2 F3 The Line Loopback sequence is sent...

Страница 86: ...t to perform Use the scroll keys if necessary F1 Rem Loopback LLBUP LLBDN 54UP F2 F3 The 54UP 54DN FT1UP and FT1DN commands send the requested sequence out the network interface on the DS0 channels al...

Страница 87: ...e DSU CSU responds to the commands transmitted on the network interface to initiate LLBs see Appendix C Configuration Options The data port configuration option NET DCLB controls whether the DSU CSU r...

Страница 88: ...perform a Line loopback 1 From the top level menu screen select Test 2 From the Test screen select Lpbk F1 Test Rlpbk Lpbk Ptrns F2 F3 3 From the Loopback screen select LLB F1 Loopback Abort LLB PLB...

Страница 89: ...RK INTERFACE ALL 1s PLB PORT 1 Procedure To perform a Payload loopback 1 From the top level menu screen select Test 2 From the Test screen select Lpbk F1 Test Rlpbk Lpbk Ptrns F2 F3 3 From the Loopbac...

Страница 90: ...TWORK INTERFACE RLB PORT 1 ALL 1s Procedure To perform a Repeater loopback 1 From the top level menu screen select Test 2 From the Test screen select Lpbk F1 Test Rlpbk Lpbk Ptrns F2 F3 3 From the Loo...

Страница 91: ...RK INTERFACE DCLB Procedure To perform a Data Channel loopback 1 From the top level menu screen select Test 2 From the Test screen select Lpbk F1 Test Rlpbk Lpbk Ptrns F2 F3 3 From the Loopback screen...

Страница 92: ...L 1s DTLB PORT 1 Procedure To perform a Data Terminal loopback 1 From the top level menu screen select Test 2 From the Test screen select Lpbk F1 Test Rlpbk Lpbk Ptrns F2 F3 3 From the Loopback screen...

Страница 93: ...t Abort F1 Loopback Abort LLB PLB F2 F3 4 From the Loopback Abort screen press the desired Function key to abort All or one specific loopback test Use the scroll keys if necessary F1 Loopback Abort Al...

Страница 94: ...ence PRBS that is 511 bits long on the data ports only This is a PRBS 29 1 test Sending Test Patterns Use the Send command to start transmission of a test pattern Only one test pattern can be active a...

Страница 95: ...dy active appears If you select a different pattern than one the DSU CSU is already sending the message Invld Test Combo appears Monitoring Test Patterns Use the Monitor command to monitor a QRSS test...

Страница 96: ...rn NET does not appear for the 511 pattern F1 Monitor Name NET Prt1 F2 F3 The Monitor screen appears with the error count If the maximum of 99999 is exceeded OvrFlw appears instead of the count If the...

Страница 97: ...and displays the message Command Complete Skip Step 5 NOTE If you mistakenly choose to abort a test pattern that is not currently running a Command Complete message still displays and the test patter...

Страница 98: ...u screen select Test 2 From the Test screen press the key until the Lamp selection appears on the screen 3 From the Test screen select Lamp F1 Test Lpbk Ptrns Lamp F2 F3 4 From the Lamp Test screen se...

Страница 99: ...he Device Health and Status screen appears automatically However the Lamp test remains active until it is aborted Aborting a Lamp Test Procedure To abort the Lamp test 1 Display the Lamp Test screen T...

Страница 100: ...loopback PLB Test Active The network interface is in Payload loopback RLB Test Active Port 1 is in Repeater loopback DCLB on Port 1 Port 1 is in a Data Channel loopback DTLB on Port 1 Port 1 is in a D...

Страница 101: ...n LLBUP LLBDN 54UP 54DN FT1UP FT1DN PLB RLB LLB Abort DCLB DTLB QRSS 1in8 511 Send Cnfig Ctrl Rel ClrReg Reset CID Passwd ACO DL Call Load Edit Area From Choose Function Activ Cust1 Cust2 Fact1 Fact2...

Страница 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 103: ...an module 115 Vac power supply 48 Vdc power supply 90 to 132 Vac 60 Hz 3 2 4 amp 215 watts at 115 Vac 60 to 40 Vdc 4 7 amps maximum POWER CONSUMPTION 6 5 watts per circuit card NETWORK T1 INTERFACE Ph...

Страница 104: ...work interface Port 1 internal clock or external clock APPROVALS Refer to the product labeling PHYSICAL DIMENSIONS Height Width Depth 7 1 inches 18 0 cm 1 0 inches 2 5 cm 14 2 inches 36 1 cm WEIGHT Ci...

Страница 105: ...iguration Options The General configuration options configure alarms and clocks on the DSU CSU Table C 3 User Interface Configuration Options The User Interface configuration options configure and con...

Страница 106: ...the data port The data rate for the port is a multiple from 1 to 24 of the base rate specified with this configuration option Nx64 Sets the base rate for this port to 64 kbps The data rate is Nx64 kbp...

Страница 107: ...DTR RTS Both Prev Send All Ones on Data Port Not Ready Specifies the conditions on the data port that determine when valid data is not being sent from the DTE When this condition is detected all ones...

Страница 108: ...is not phase inverted InvrtData Disab Next Enab Disab Prev Invert Transmitted and Received Data Specifies whether the port s transmitted data and received data are logically inverted before being tra...

Страница 109: ...are detected in a 60 second period It is cleared with less than 10 errors in 60 seconds 10E 8 10E 8 Threshold For example at 1536 kbps EER is declared if more than 41 CRC5 errors are detected in thre...

Страница 110: ...available if EDL is disabled If the local DSU CSU is configured to maintain far end performance statistics then the remote device must be configured to send near end performance statistics Mgmt Link...

Страница 111: ...ext Enab Disab Prev Generate ANSI Performance Report Messages Specifies whether ANSI T1 403 compliant performance report messages PRMs are generated Enab Generates and sends ANSI PRMs over the Facilit...

Страница 112: ...terminate the PLB Disab Causes the DSU CSU to ignore PLB Actuate and PLB Release commands the DSU CSU is not in compliance with ANSI T1 403 and AT T TR 54016 NOTES When this configuration option is e...

Страница 113: ...e master clock Failure of the clock specified by the Clock Source selection results in automatic fallback to internal clock NET Configures the network interface as the master clock source Prt1 Configu...

Страница 114: ...les a self test Disab Disables the self test Dial In Enab Next Enab Disab Prev Dial in Access Allows dial in access to the DSU CSU For standalone DSU CSUs dial in access is through the modem port For...

Страница 115: ...mmunication port AT Allows standard AT commands to be sent out the communication port Other Allows user configurable commands to be sent out the communication port NOTES This configuration option is n...

Страница 116: ...Once the external device connection has been established either you or the DSU CSU can command the external device to disconnect Before doing so you may need to send the escape sequence out to switch...

Страница 117: ...mExtDev configuration option is set to AT or the communication port is disabled Com Rate 9 6 Next 1 2 2 4 4 8 9 6 14 4 19 2 Prev Communication Port Rate Configures the bit rate for the communication p...

Страница 118: ...tion must be set to Enab Use the left or right arrow key to position the cursor on the digit you want to change Use the Function keys Up or Down to increment or decrement the digit Up Increments the t...

Страница 119: ...0 minutes before the Telnet session disconnects due to inactivity The TnInActTm configuration option must be set to Enab Use the left or right arrow key to position the cursor on the digit you want to...

Страница 120: ...gement link Disab Disables sending SNMP trap messages from this unit over any SNMP management link Trap Disc Enab Next Enab Disab Prev SNMP Trap Disconnect Specifies whether the modem connection or ca...

Страница 121: ...enabled the call is retried once per alarm or trap message A delay as specified by the dial out delay time is imposed between call attempts If an alternate dial out directory is specified both the ala...

Страница 122: ...is declared if more than 41 CRC6 errors are detected in three 15 minute intervals 10E 9 EER is declared if more than 4 CRC6 errors are detected in three 15 minute intervals AlrmRelay Disab Next Enab D...

Страница 123: ...using the NMS n IP Adr configuration option Enab The DSU CSU validates the IP address of SNMP management systems attempting to access the DSU CSU Disab The DSU CSU does not validate the IP address of...

Страница 124: ...System Name Next Edit Clear Prev System Name Specifies the system name for this unit This is the name of this SNMP managed node Edit Allows you to edit or display the system name Clear Allows you to c...

Страница 125: ...the MIB Edit Allows you to edit or display the second community name Clear Allows you to clear the second community name Access 2 Read Next Read R W Prev Access 2 Specifies the type of access allowed...

Страница 126: ...subnet mask based on the class of the IP address Class A 255 000 000 000 Class B 255 255 000 000 or Class C 255 255 255 000 NOTE This configuration option is not available if the communication port i...

Страница 127: ...m The Trap Manager n network destination is the communication port This selection only appears if the Com Use configuration option is set to Mgmt FDL The Trap Manager n network destination is the FDL...

Страница 128: ...ents Up Sends trap messages for linkUp events to the currently configured trap manager s Down Sends trap messages for linkDown events to the currently configured trap manager s Both Sends trap message...

Страница 129: ...s appendix describes connector pin assignments and cables T1 Network Interface The T1 network interface connector is an RJ48C 8 position unkeyed modular jack Table D 1 The T1 line interface cable is a...

Страница 130: ...Pin Assignments D 2 3166 A2 GB20 20 March 1999 Figure D 1 T1 Line Interface Cable RJ48C to RJ48C Figure D 2 T1 Line Interface Cable RJ48C to DA15P...

Страница 131: ...ata BB 104 From DSU CSU 3 A 16 B Request to Send CA 105 To DSU CSU 4 A 19 B Clear to Send CB 106 From DSU CSU 5 A 13 B Received Line Signal Detector CF 109 From DSU CSU 8 A 10 B DCE Ready CC 107 From...

Страница 132: ...8 26 7 25 9 27 12 13 31 11 19 14 10 20 17 35 18 29 30 SHIELD TD A TD B RD A RD B TXC A TXC B RXC A RXC B RTS A RTS B CTS A CTS B DTR RLSD A RLSD B DSR SIG COMMON RL LL RCV COMMON TT A TT B TM SIG COM...

Страница 133: ...DSU CSU 6 A 24 B Request to Send RS 105 To DSU CSU 7 A 25 B Clear to Send CS 106 From DSU CSU 9 A 27 B Receiver Ready RR 109 From DSU CSU 13 A 31 B Data Mode DM 107 From DSU CSU 11 A 29 B Terminal Rea...

Страница 134: ...9 4 5 8 6 7 24 11 20 21 18 25 23 A P S R T Y AA V X C D F E B U W H N L NN SHIELD TD A TD B RD A RD B TXC A TXC B RXC A RXC B RTS CTS RLSD DSR SIG COMMON TT A TT B DTR RL LL TM SIG COMMON SHIELD TD A...

Страница 135: ...nd 106 From DSU CSU D Data Channel Received Line Signal Detector 109 From DSU CSU F Data Set Ready 107 From DSU CSU E Data Terminal Ready 108 1 2 To DSU CSU H Transmit Signal Element Timing DTE Source...

Страница 136: ...RTS B RLSD A RLSD B SIG COMMON TT A TT B 530 SIGNAL DB25 PLUG DB15 SOCKET X 21 SIGNAL 495 14787 Figure D 5 EIA 530 A to X 21 Adapter Table D 5 X 21 Cable Interface Signal CCITT Number Direction Pin S...

Страница 137: ...to the DSU CSU The COM port connector is an 8 position unkeyed modular connector Table D 6 The data signals on this port are referenced to a DTE interface The COM port to PC cable is shown in Figure...

Страница 138: ...Pin Assignments D 10 3166 A2 GB20 20 March 1999 Figure D 6 COM Port to PC Cable Figure D 7 COM Port to Terminal Printer Cable...

Страница 139: ...nal device Figure D 8 shows the pin assignments from the COM port to the external device 1 2 3 4 5 6 7 8 97 15669 COM Port Non Keyed 8 Position Modular Plug Tx Clock Rx Data Signal Ground Tx Data DTR...

Страница 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 141: ...ntrol Protocol Internet Protocol TCP IP internets and provides general information about the DSU CSU RS 232 like MIB Defines objects for managing RS 232 type interfaces and supports synchronous data p...

Страница 142: ...ssion Group Supported on the synchronous data port using the RS 232 like MIB Supported on the COM port using the RS 232 like MIB SNMP Group Supported System Group MIB II The System Group objects are f...

Страница 143: ...rk 2 Layer 2 functionality SLIP PPP for the COM AUX and MODEM ports internet 4 Layer 3 functionality IP for all management links end to end 8 Layer 4 functionality UDP for all management links Therefo...

Страница 144: ...the CSU board for the standalone or the CCA number for the DSU board for the carrier Data Port Data Port 1 Company Name T1 DSU CSU Hardware Version CCA number for the DSU board where n is 1 to 4 Inte...

Страница 145: ...SNMP management link is active on the COM port testing 3 The SNMP management link is inactive on the COM port These ports can be used for proprietary ASCII functions Interface Group ifOperStatus Obje...

Страница 146: ...management link For an interface that is not configured as an SNMP management link these statistics are not provided and an error status is returned if access is attempted The objects used to collect...

Страница 147: ...proprietary interface which is not currently implemented by the interface group of MIB II IP Group ipRouteTable Object ip 21 The routing table used by the DSU CSU is supported as a read write table En...

Страница 148: ...st be unique only one route per destination may appear in the table To ensure that no duplicate destinations appear in the routing table the ipRouteDest object of the ipRouteTable will be treated as d...

Страница 149: ...added or modified as a result of user configuration via the front panel netmgmt 3 Route added or modified by means of an SNMP set icmp 4 Route added or modified by Internet Control Management Protocol...

Страница 150: ...e synchronous data port and the COM port port The ds1 transmission object is defined by the DS1 E1 MIB The rs232 transmission object is defined by the RS 232 like MIB SNMP Group MIB II The SNMP Group...

Страница 151: ...coding Near End Group dsx1SendCode Object dsx1ConfigEntry 7 This object specifies the test patterns codes being sent over the network interface Only the following values are supported by the DSU CSU d...

Страница 152: ...More than one value may be active at a time dsx1NoAlarm 1 No alarm present dsx1RcvFarEndLOF 2 A yellow alarm signal is being received dsx1RcvAIS 8 An Alarm Indication Signal AIS is being received dsx1...

Страница 153: ...orted by the DSU CSU More than one value may be active at a time dsx1other 1 SNMP data is being sent over FDL dsx1Ansi T1 403 2 ANSI PRMs are supported on the network interface as specified by ANSI T1...

Страница 154: ...the interval dsx1Interval BESs Bursty Errored Seconds for the interval Near End Group The DS1 Total Table Objects dsx1TotalEntry The following DS1 total table objects are provided for the network int...

Страница 155: ...not supported by the DSU CSU for the synchronous data port The following sections provide clarification for objects contained in the RS 232 like MIB when it is not clear how the object definition in...

Страница 156: ...For the DSU CSU the rs232PortInSpeed object has the same value as the rs232PortOutSpeed object The input speed of the synchronous data port is determined by the channel configuration and cannot be cha...

Страница 157: ...ous Port Table rs232AsyncPortAutoBaud rs232AsyncPortEntry 5 This object specifies the ability to automatically sense the input speed of the port Only the following value is supported by the DSU CSU di...

Страница 158: ...signal is not asserted Input Signal Table rs232InSigChanges rs232InSigEntry 4 This object is not supported by the DSU CSU Output Signal Table RS 232 like MIB This object contains entries for the outpu...

Страница 159: ...t stop the Monitor QRSS test pattern on the network interface Start stop the Send QRSS 511 test pattern on a synchronous data port Start sending a V 54 FT1 UP DOWN code to the remote unit for a synchr...

Страница 160: ...ests 3 testMon511 OBJECT IDENTIFIER wellKnownTests 4 testSendQRSS OBJECT IDENTIFIER wellKnownTests 5 testSend511 OBJECT IDENTIFIER wellKnownTests 6 testSendV54Up OBJECT IDENTIFIER wellKnownTests 7 tes...

Страница 161: ...ors A monitor pattern QRSS or 511 test has synchronized on the pattern and has detected bit errors notInSync A monitor pattern QRSS or 511 test has not synchronized on the requested pattern Where thes...

Страница 162: ...ET Read the dsx1LineStatus object for NET T1 dsx1LossOfSignal dsx1LossOfFrame dsx1RcvFarEnd dsx1RcvAIS dsx1OtherFailure Stat Perf Telco Cur CurTimer ES UAS SES BES CSS Read the value in the following...

Страница 163: ...tMon511 from ifExtnsTestType for Port 1 Stat LED Prtn DTR CTS RTS Read rs232InSigState from rs232InSigName dtr rs232outSigState from rs232OutSigName ctr rs232InSigState from rs232InSigName rts Stat ID...

Страница 164: ...ifExtnsTestType for Net T1 to testMonQRSS Set ifExtnsTestType for Net T1 to noTest Test Ptrns Mon QRSS Prt1 Test Ptrns Abort Mon Prt1 Set ifExtnsTestType for Port 1 to testMonQRSS Set ifExtnsTestType...

Страница 165: ...g Activ Edit User Com Rate Set Display rs232PortInSpeed or rs232PortOutSpeed for COM port Cnfig Activ Edit User Char Length Cnfig Activ Edit User MChar Len Set Display rs232AyncPortBits for COM port C...

Страница 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 167: ...one Model 3165 1 port standalone Connections to remote devices may be via EDL for the Model 3166 and 2 port and 4 port DSU CSUs or FDL however the FDL is only available on full T1 links not fractional...

Страница 168: ...he first scenario Figure F 1 is a series of standalone 31xx Series devices daisy chained together with remotes connected via the FDL In this scenario all 31xx Series devices are on the same subnet 135...

Страница 169: ...All devices are still on the same subnet and the subnet mask is FF FF FF 00 A static route still must be set in the NMS host to subnet 135 18 2 0 ETHERNET 135 18 2 17 496 14646 02 LAN ADAPTER FT1 CO...

Страница 170: ...A static route must be set up in the NMS host for each subnet 135 18 4 0 135 18 6 0 135 18 20 0 ETHERNET 135 18 6 34 496 14647 02 LAN ADAPTER T1 CO MS PH ER E 361 0 CO MS PH ER E 361 0 135 18 6 22 135...

Страница 171: ...only one route must be added to the NMS host 135 18 0 0 ETHERNET 135 19 6 34 496 14648 02 LAN ADAPTER T1 CO MS PH ER E 361 0 CO MS PH ER E 361 0 135 19 6 22 135 19 6 1 135 19 6 16 135 18 40 1 COM IP A...

Страница 172: ...separate subnet Also note that each LAN Adapter connection is on a different subnet The subnet mask is FF FF FF 00 The NMS hosts would only need routes added for the subnets that they are to manage E...

Страница 173: ...rs on the PC The functionality of the front panel is available by clicking on the Function keys with the mouse rather than by pressing keys from the actual front panel Installing Front Panel Emulation...

Страница 174: ...ion drive followed by a colon default is C then the appropriate directory name default is C FRONTPAN If the selected directory already exists the following message appears The specified directory alre...

Страница 175: ...con that appears after the Front Panel Emulation program is installed on the PC The Front Panel window opens 3 Double click on the Front Panel icon that appears in the Front Panel window The Front Pan...

Страница 176: ...er the telephone number of the far end DSU CSU in the Phone Number field then click on the Dial button 7 The front panel of the selected DSU CSU appears on the PC NOTE When using Front Panel Emulation...

Страница 177: ...User Interface User configuration options for ATI operation Refer to Changing Configuration Options in Chapter 3 Operation and Appendix C Configuration Options To connect the ATI to the DSU CSU using...

Страница 178: ...port see Appendix F IP Network Addressing Scenarios If a password is required the Login screen displays the prompt for password input Refer to Entering a Password to Gain Access on page H 13 To move...

Страница 179: ...atistics Display LEDs Identity Call Setup Call Directories Customer ID Administer Password System Alarm Relay Cut Off Start Download Select Monitor Jack Select LEDs System and Test Status Network Sync...

Страница 180: ...For example if the values for a field can be NET or PORT and you enter a P and press Return Enter then the value PORT automatically appears in the field Once an operation is initiated status messages...

Страница 181: ...ar Selects the next valid value for the field Delete Deletes the character that the cursor is on Up Arrow key or Ctrl u Moves the cursor up one field within a column on the same screen Down Arrow key...

Страница 182: ...he customer identification The customer identification may be up to 8 characters long Select Clear to remove all the characters in the associated field 4 Select Save to store the information in nonvol...

Страница 183: ...select Status The Status screen appears 2 From the Status screen select Display LEDs The Display LEDs screen appears Figure H 4 The screen shows a snapshot of the LEDs every 5 seconds LEDs that are i...

Страница 184: ...Configuration is read only is displayed on line 24 Displaying or Editing Configuration Options Procedure To display or edit configuration options 1 From the Main Menu screen select Configuration The...

Страница 185: ...nfiguration Edit Display screen appears Figure H 6 3 Select a functional group to display or edit NOTE Screen displays may vary depending on the model and configuration of the DSU CSU For example DTE...

Страница 186: ...erwrite the existing Customer configuration options and store these changes for future use To protect you from accidentally exiting an edit session before saving your changes the system displays the S...

Страница 187: ...nfiguration Edit Display screen select User Interface The User Interface Options screen appears 4 From the User Interface Options screen select Communication Port The Communication Port Options screen...

Страница 188: ...Figure H 9 This screen is used to add a new password or modify an existing password 3 Enter a new password in the Password field The password may be 1 to 8 characters long and may contain the charact...

Страница 189: ...U s top level menu appears If the password is invalid an invalid password message appears and the screen reappears and waits for password entry If an invalid password is entered three consecutive time...

Страница 190: ...Asynchronous Terminal Interface Operation H 14 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 191: ...1 Line Interface Cable RJ48C to DA15P Canada 15 m 3100 F1 510 COM Port to Terminal Printer Cable 8 pin modular to DB25P 14 ft 3100 F1 540 COM Port to PC Cable 8 pin modular to DB9S 14 ft 3100 F1 550 E...

Страница 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...

Страница 193: ...ll ones signal transmitted to maintain transmission continuity and to indicate to the receiving terminal that a transmission fault exists at either the transmitting terminal or upstream of the transmi...

Страница 194: ...h bits are transmitted across a data connection Bipolar Violation In a bipolar signal a one mark pulse which has the same polarity as its predecessor A sequence of successive bits usually eight handle...

Страница 195: ...options Customer 2 configuration area The second of two sets of customer defined configuration options The transmission standard that specifies 12 frames as a superframe that is used for frame synchro...

Страница 196: ...provides data in the form of digital signals for transmission Data Terminal Loopback Loopback mode that loops the data for a particular synchronous data port back to the port just before it is combin...

Страница 197: ...els that may be sold separately or in groups to provide bandwidth that is some fraction of the total E1 capability One identifiable group of bits that includes a sequence of bits for control framing e...

Страница 198: ...ne LoopBack A test in which the received signal on the network interface is looped back to the network without change Loss of Frame Occurs when a DS1 terminal is unable to synchronize on the DS1 signa...

Страница 199: ...s marks pulses is not adequate for the line requirement Performance Report branch of the DSU CSU menu tree Payload Loopback Loopback mode that loops the information received on the T1 network interfac...

Страница 200: ...objects for managing RS 232 type interfaces e g RS 422 RS 423 etc and supports synchronous data ports and management communication ports on the device An Electronic Industries Association s standard f...

Страница 201: ...otocols Allows the user of one host computer to log into a remote host computer and interact as a normal terminal user of the remote host One of the ways in which bandwidth can be specified for multip...

Страница 202: ...is band is used by the modem for its modulated signal Wide Area Network A network that spans a large geographic area An SNMP trap that indicates that the device has reinitialized itself External Trans...

Страница 203: ...s report 4 8 Bit Stuffing configuration option C 8 block method of channel allocation 3 32 C cabling pin assignments D 1 Call Retry on Alarm or Trap C 17 CID Customer Identification branch example of...

Страница 204: ...cation 3 5 Performance Report message 4 9 troubleshooting 4 14 EER at Prt1 Device Health and Status message 4 4 EIA 530 A interface D 3 Embedded Data Link EDL 1 2 configuration option C 4 C 6 used wit...

Страница 205: ...P 1 2 Master Clk fail Device Health and Status message 4 4 master clock functional description 3 35 procedure for configuring 3 35 messages alarm Performance Report 4 7 Self Test Health 4 2 troublesho...

Страница 206: ...41 Reset branch example of use 3 41 Rlpbk Remote Loopback branch example of use 4 16 RS 449 interface D 5 S self test enabling and disabling C 10 self test displaying results 4 1 front panel indicati...

Страница 207: ...B 4 22 remote loopback 4 16 test messages 4 32 test patterns 4 26 Test Duration C 10 Test in progress Device Health and Status message 4 4 test jacks functional description 4 15 physical description 3...

Отзывы: