2. Installation
2-8
March 2001
3160-A2-GB24-10
Installing the Redundant –48 Vdc Power Supply
To install the Model 3164 DSU/CSU using a redundant – 48 Vdc SELV power
supply, refer to
Figure 2-10, –48 Vdc Redundant Source Power Supply Pinouts
,
and use the following procedure.
Procedure
To install the redundant – 48 Vdc power supply:
1. Connect the black wire to the –48 Vdc return source B.
2. Connect the red wire to the –48 Vdc return source A.
3. Connect the green wire to a suitable ground.
4. Connect the orange wire to the –48 Vdc input source B.
5. Connect the blue wire to the – 48 Vdc input source A.
6. Cut the white wire off at the outer insulation.
7. Plug the power connector into the DSU/CSU.
Figure 2-10. –48 Vdc Redundant Source Power Supply Pinouts
1
2
3
4
5
6
BLACK
RED
GREEN
WHITE
ORANGE
BLUE
– 48 VDC RETURN B
– 48 VDC RETURN A
GROUND
– 48 VDC INPUT B
– 48 VDC INPUT A
99-14300-02
X
DSU/CSU POWER
PLUG
TO CUSTOMER-SUPPLIED BATTERY
Содержание 3160-A4
Страница 14: ...Contents viii March 2001 3160 A2 GB24 10 ...
Страница 18: ...About This Guide xii March 2001 3160 A2 GB24 10 ...
Страница 26: ...1 Introduction 1 8 March 2001 3160 A2 GB24 10 ...
Страница 38: ...2 Installation 2 12 March 2001 3160 A2 GB24 10 ...
Страница 54: ...3 Using the Front Panel 3 16 March 2001 3160 A2 GB24 10 ...
Страница 102: ...4 Configuration 4 48 March 2001 3160 A2 GB24 10 ...
Страница 110: ...5 Security 5 8 March 2001 3160 A2 GB24 10 ...
Страница 162: ...8 Testing 8 24 March 2001 3160 A2 GB24 10 ...
Страница 164: ...A Front Panel Menu A 2 March 2001 3160 A2 GB24 10 ...
Страница 222: ...D Configuration Worksheets D 14 March 2001 3160 A2 GB24 10 ...
Страница 240: ...E Pin Assignments E 18 March 2001 3160 A2 GB24 10 ...
Страница 272: ...F SNMP MIB Objects F 32 March 2001 3160 A2 GB24 10 ...
Страница 280: ...G IP Network Addressing Scenarios G 8 March 2001 3160 A2 GB24 10 ...
Страница 300: ...J Equipment List J 2 March 2001 3160 A2 GB24 10 ...