Omnia 3

  

The Omnia Wireless Receiver Module (OMN-RCV3) allows you to add up to 8 fully
supervised Omnia wireless motion detectors and/or door contacts, and up to 8
programmable remote controls to the Spectra system.

1.1 TECHNICAL SPECIFICATIONS

• Di-pole antenna
• Error Correction Algorithm
• Code-Hopping Technology
• Frequency: 433 

MHz

• Range (line of sight): 

PIRs & door contacts =

500ft (150m) 

remote controls = 

300ft (100m) 

• Sensitivity: -120 

dBm

• Current consumption: 

50 mA

• Dimensions (no antenna): 

15cm H x 16cm L x 3cm W 
(6in H x 6.5in L x 1.1in W)

• Operating temperature: 

0°C to 50°C (32°F to 122°F)

• Operating humidity: 

85%

• Approvals:

1.2 SYSTEM FEATURES

• Auto-Panel Recognition
• Add 8 wireless motion detectors and/or door contacts to the Spectra system
• Add 8 remote controls to the Spectra system
• Reflow design
• On-board tamper switch
• Full system supervision (check-in, low battery and tamper)
• Transmitter signal strength indicator 

Содержание Spectra Omnia OMN-RCV3S

Страница 1: ...Wireless Receiver Module V1 0 Reference Installation Manual...

Страница 2: ...umbers 10 System Reset 10 SUPERVISION OPTIONS 10 Check In Supervision 10 Check In Supervision Timer Settings 11 Low Battery Supervision 12 On Board Module Tamper Supervision Zone Assignment 12 REMOTE...

Страница 3: ...IRs door contacts 500ft 150m remote controls 300ft 100m Sensitivity 120 dBm Current consumption 50 mA Dimensions no antenna 15cm H x 16cm L x 3cm W 6in H x 6 5in L x 1 1in W Operating temperature 0 C...

Страница 4: ...l for maximum allowable distances between the control panel and the Wireless Receiver Module 2 2 CONNECTIONS AND MOUNTING Firmly screw the antenna into the connector marked ANT on the Receiver Module...

Страница 5: ...Omnia 5 Figure 2 1 Connecting the OMN RCV3 to the control panel...

Страница 6: ...ensure proper synchronization between the transmitters and receiver open and close the transmitters covers and zones 3 1 HOW TO ENTER PROGRAMMING MODE Programming of the OMN RCV3 is done in Programmin...

Страница 7: ...gramming Guide Table 3 1 Sections and Expansion Inputs Do not assign detection devices from different modules to the same expansion input For example do not assign a wireless transmitter to section 60...

Страница 8: ...stallation Manual for instructions on programming the zones 3 3 VIEWING THE TRANSMITTER SIGNAL STRENGTH SECTIONS 631 TO 638 Once the detectors and or door contacts have been installed and assigned to...

Страница 9: ...a transmitter s signal strength In step 3 in section 3 1 on page 6 1 Enter the desired SECTION NUMBER 631 to 638 2 Press the transmitter s tamper switch or open the corresponding zone On an LED keypad...

Страница 10: ...If a device has not sent a signal within that time period the Wireless Receiver Module will transmit a supervision loss signal to the control panel The control panel can then generate a trouble an ala...

Страница 11: ...od defined here it can send a Supervision Loss signal to the control panel Refer to section 4 1 for instructions on enabling check in supervision The assigned transmitters must be set to the same Chec...

Страница 12: ...the control panel via the communication bus The Zone Tamper report code will originate from the zone defined by the Expansion Input 001 008 you have programmed in section 615 Please note that the corr...

Страница 13: ...in sections 701 to 708 3 The remote control s buttons are programmed in sections 711 to 718 The remote control will transmit a signal for only 1 second when a button is pressed This is done to conserv...

Страница 14: ...TE CONTROL BUTTONS SECTIONS 711 TO 718 Each remote control can be programmed to send a signal to the control panel to perform up to 8 different actions Each digit in sections 711 to 718 represents a b...

Страница 15: ...time to save and exit Note Press the FORCE button 8 times that is once for every button or button combination Remote Control Button Programming refer to Table 5 2 Section 711 ____ ____ ____ ____ ____...

Страница 16: ...at have Event Group 08 as their Activation Event 6 Disarm when there is no alarm D Activates any PGMs that have Event Group 09 as their Activation Event Value or Action What Do I Press What Do I See 1...

Страница 17: ...ming user option Also if you enable any Panic button options you must enable the Panic options in the Spectra control panel refer to the appropriate Spectra Reference Installation Manual 5 4 DELETING...

Страница 18: ...Enter the desired SECTION NUMBER 731 to 738 2 Press the FORCE button How to replace the remote control batteries 1 Remove the two screws from the back of the remote control and remove the back cover 2...

Страница 19: ...time value 615 On board module tamper supervision zone assignment 630 Viewing unknown serial numbers 631 to 638 Viewing the detector and door contact signal strengths 701 to 708 Assigning the remote c...

Страница 20: ...may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limi...

Страница 21: ......

Отзывы: