12
Programming Guide
SYSTEM OPTIONS
Bold
= Default Setting
SECTION [127]: General Options
Option
OFF
ON
[1]
Partitioning
l
Disabled
l
Enabled
[2]
Access Code Length
l
6-digits
l
4-digits
[3]
Keypad Audible Trouble Warning
l
Disabled
l
Enabled
[4]
Lock System Master Code
l
Disabled
l
Enabled
[5]
Battery Charge Current
l
350mA
l
700mA
[6]
User Code 048 is a Duress Code
l
Disabled
l
Enabled
[7]
Alarm Relay follows (1755/EX & 1758/EX only)
l
Bell Output
l
Global PGM
[8]
Normal State of PGM1
l
Normally Closed (N.C.)
l
Normally Open
SECTION [128]: General Options
Option
OFF
ON
[1]
Panic 1: Keys [1] & [3]
l
Disabled
l
Enabled
[2]
Panic 2: Keys [4] & [6]
l
Disabled
l
Enabled
[3]
Panic 3: Keys [7] & [9]
l
Disabled
l
Enabled
[4]
Panic 1: Silent or Audible
l
Silent
l
Audible
[5]
Panic 2: Silent or Audible
l
Silent
l
Audible
[6]
Panic 3: Silent or Fire
l
Silent
l
Fire
[7]
Keypad 1 Tamper Supervision
l
Disabled
l
Enabled
[8]
Keypad 2 Tamper Supervision
l
Disabled
l
Enabled
SECTION [129]: General Options
Option
OFF
ON
[1]
PGM2 Output Activation Option*
l
Steady
l
Pulse (flash)
[2]
PGM2 Pulse Once Every 30sec. If System Armed*
l
Disabled
l
Enabled
[3]
PGM2 Pulse On Arm, Twice On Disarm*
l
Disabled
l
Enabled
[4]
SPC-ZX4/8 Zone Expansion Module Supervision
l
Disabled
l
Enabled
[5]
SPC-319 Wireless Module Supervision
l
Disabled
l
Enabled
[6]
SPC-319 Wireless Module Low Battery Super.
l
Disabled
l
Enabled
[7]
Siren Driver* on Bell Output
l
Disabled
l
Enabled
[8]
Normal State of PGM2
l
Normally Closed (N.C.)
l
Normally Open
*1755, 1755EX, 1758 and 1758EX only
SECTION [130]: Arming/Disarming Options
Option
OFF
ON
[1]
One-Touch Regular Arming
l
Disabled
l
Enabled
[2]
One-Touch Stay Arming
l
Disabled
l
Enabled
[3]
One-Touch Force Arming
l
Disabled
l
Enabled
[4]
One-Touch Bypass Programming
l
Disabled
l
Enabled
[5]
Restrict Arming on Battery Failure
l
Disabled
l
Enabled
[6]
Restrict Arming on Tamper Trouble
l
Disabled
l
Enabled
[7]
Bell Squawk on Arm/Disarm with Keypad
l
Disabled
l
Enabled
[8]
Beep on Exit Delay
l
Disabled
l
Enabled
Содержание Spectra 1725
Страница 1: ...PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1 2 1725 1725EX 1728 AND 1728EX 1755 1755EX 1758 AND 1758EX...
Страница 2: ......
Страница 5: ...Spectra Series 3...
Страница 37: ...Spectra Series 35 HARDWARE CONNECTIONS SINGLE ZONE INPUTS DOUBLE ZONE INPUTS with ATZ option only...
Страница 38: ...36 Programming Guide CONNECTING A KEYSWITCH CONNECTING FIRE CIRCUITS PGM CONNECTIONS...
Страница 39: ...Spectra Series 37 CONNECTING A LIBERATOR WIRELESS BUS MODULE SPC 319 CONNECTING A ZONE EXPANSION MODULE SPC ZX8...
Страница 40: ...38 Programming Guide SPECTRA 1725 1725EX 1728 AND 1728EX PCB LAYOUT...
Страница 42: ......