
SP+ Series Programming Guide
59
PCB Layout
40 VA transformer strongly recommended.
This equipment must be installed and maintained by qualified service personnel only.
Max. number of keypads: 15 bus modules
Max. aux. current: 700 mA
Power consumption (idle): 52 mA
Max. distance of bus module from panel: 76 m (250 ft.)
Max. total run of wire: 230 m (750 ft.)
The sum of the current drawn from the
BELL
and
AUX
must be limited to 1.3A. Exceeding this limit will overload the panel power supply
and lead to complete system shutdown.
1 PGM Jumper: allows you to choose whether the solid state
relay PGMs are ground (-), or give out 12V (+)
2 AUX LED:
•
ON = Aux present; OFF = Aux off
3 Four-pin connector can be used for quick installation of a keypad
4 EBUS and Dialer used with:
•
VDMP3 Plug-In Voice Module for voice reporting
•
PCS Series Communicator Module
5
LEDs
Status LED:
•
Flash once every second: Normal
•
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
•
Always ON: Panel is using phone line
•
Fast flash 6 seconds after power-up: Installer lock enabled
Charge LED:
Charging and battery test LED
6 Panel reset
7 Serial 1: Used as the primary reporting channel for connecting the IP
Module/PCS Module
8 Serial 2: Used as a backup reporting channel for connecting the IP
Module/PCS Module
9 Zone Input
10 The
BELL
output will shutdown if the current exceeds 3A
11 PGM output connector
12 AC Power connections
13 Backup Battery connections
14 AWG#14 single conductor solid copper wire
15 Ground clamp
16 Cold water pipe grounding
17 To ground
18 Keypad’s zone configuration
19 Zone connections, if EOL is enabled, see section
[706]
option 2
20 To connect additional wiring to auxiliary power, use the red (
+
) and black
(
-
) keypad connectors; auxiliary power will shut down if current exceeds
1.1A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
To provide maximum
lightning protection we
strongly recommend having
separate earth connections
for the dialer and zone
ground terminals.
Enter section [300] to
unlock your SP+ panel
serial ports for use with
third-party devices
using a TM70/TM50
Touch keypad and
.
Содержание SP5500+
Страница 1: ...SP5500 SP6000 SP7000 Programming Guide 4 to 32 Zone Expandable Security Systems ...
Страница 65: ...SP Series Programming Guide 65 Notes ...
Страница 66: ...66 SP Series Programming Guide ...
Страница 67: ......