Country Codes
Table 30 lists countries and their respective codes. This information is required when programming section
[731]
(see worksheet 31 for details).
Customized Daylight Savings Features
In addition to using the default Daylight Saving Time (DST) settings in section
[731]
, you can also set a customized DST. In sections
[732]
and
[733]
, you can
program DST starting and ending periods, respectively. Both these sections recognize five different entries, consisting of two digits each.
All entries must be made in the following order:
1.
Month
: 01 to 12, where
01
represents January
2.
Date
: 01 to 31, where
01
represents the first day of the month
3.
Day
: 00 to 07, where
00
is the default setting and
01
represents Sunday
4.
Hours
: 00 to 23, where
00
represents 12:00 AM
5.
Minutes
: 00 only, where
00
represents the top of the hour (e.g., 12:
00
AM)
NOTE:
If the
Day
value is set to
00
, it is ignored and the DST change will only respect the
Date
value. If the
Day
setting is set to a value other than
00
(e.g.,
03
for
Tuesday), the DST time change will occur on the first Tuesday following the programmed
Date
value.
NOTE:
If sections
[732]
and
[733]
have been modified, but you want to revert to a standard DST code, change all settings in sections
[732]
and
[733]
to
00
.
Partition Programming
Use the following section to program partitions on your SP+ Series control panel.
Partition Options
Table 30: Country codes for SP+ control panels
Input Value
Country
Input Value
Country
00
Mexico; St. Johns; Bahamas; Turks and Caicos
10
Chatham
01
Cuba
11
Tonga
02
Brazil
12
Iraq; Syria
03
Chile
13
Israel
04
Falkland Islands
14
Lebanon; Kyrgyzstan
05
Paraguay
15
Palestine
06
European Union; United Kingdom; Greenland
16
Egypt
07
Russia and surrounding countries
17
Namibia
08
South Australia; Victoria; Australian Capital Territory; New
South Wales
18
Canada; United States
09
Tasmania; Lord Howe Island
19
New Zealand
Worksheet 31: Daylight Savings Time
Section
Data
Description
[731]
___/___
00 to 99
Country code
[732]
__/__/__/__/__/__/__/__/__/__
Month-date-day-hours-minutes
DST staring period
[733]
__/__/__/__/__/__/__/__/__/__
Month-date-day-hours-minutes
DST ending period
Table 31: Description of partition 1 options (section [741])
Option
Description
OFF
ON
Option
Description
Sec
tion
[741]
1
Auto-arm on time
Disabled
Enabled
3
4
2
Auto-arm on no movement
Disabled
Enabled
OFF
OFF
Regular (default)
3 & 4
Auto-arm arming mode
See options 3
& 4, on right
See options 3
& 4, on right
OFF
ON
Sleep
5
Switch to stay arming, if no entry zone is opened
Disabled
Enabled
ON
OFF
Stay
6
Follow zones become entry delay 2, when delay
zone is bypassed
Disabled
Enabled
= Default