50
Programming Guide
Trouble Display
- Press the
[
TBL
]
key to view the Trouble Display. Please note that the keypad can be programmed to emit a beep every 5 seconds
whenever a new trouble condition has occurred. Press the
[
TBL
]
key to stop the beeping.
- To view the sub-menu, press the corresponding key in the main menu.
Installer Function Keys
To access the Installer Function keys, press:
[
ENTER
]+[
INSTALLER
CODE
] + [
MEM
]
=
Test Report:
Send the “Test Report” report code programmed in section
[840]
monitoring station.
[
ENTER
]+[
INSTALLER
CODE
] + [
STAY
]
=
Cancel Communication:
Cancels all communication with the WinLoad software or with the
monitoring station until the next reportable event.
[
ENTER
]+[
INSTALLER
CODE
] + [
SLEEP
]
=
Answer WinLoad Software:
Will force the console to answer an incoming call from the
monitoring station that is using the WinLoad software.
[
ENTER
]+[
INSTALLER
CODE
] + [
BYP
]
=
Call WinLoad Software:
Will dial the PC telephone number programmed in section
[915]
(page 44) in order to initiate communication with a computer using the WinLoad software.
[
ENTER
]+[
INSTALLER
CODE
] + [
TBL
]
=
Installer Test Mode:
The installer test mode will allow you to perform walk tests where the siren
will squawk to indicate opened zones. Press the
[
TBL
]
key again to exit.
Main Menu Trouble
Sub-Menu Trouble Menu
[1]
Wireless zone low battery
[1]
to
[32]
Zones in low battery
[2]
Power trouble
[1]
Low/No battery on the control panel
[2]
AC failure on control panel
[3]
Auxiliary overload on control panel
[4]
Wireless keypad AC failure
[5]
Wireless keypad battery failure
[6]
Wireless repeater AC failure
[7]
Wireless repeater battery failure
[3]
Bell trouble
[1]
Bell disconnect on control panel
[2]
Bell overload on control panel
[4]
Communication trouble
[1]
Telephone Line Monitoring on control panel
[2]
Fail to communicate on Monitoring Telephone 1 on control panel
[3]
Fail to communicate on Monitoring Telephone 2 on control panel
[4]
Fail to communicate on pager telephone on control panel
[5]
Fail to communicate on voice telephone on control panel
[6]
Fail to communicate with PC on control panel
[5]
Tamper and zone wiring failure
[1]
to
[32]
Zones in tamper and zone wiring failure
[6]
Module tamper trouble
[1]
MG-2WPGM
[2]
Keypad bus
[3]
ZX8 bus module
[4]
RTX3 bus module
[5]
Wireless keypad
[7]
Fire loop trouble
[1]
to
[32]
Zones in fire loop trouble
[8]
Timer loss
[9]
Wireless zone supervision loss
[1]
to
[32]
Zones in supervision lost
[
STAY
]
RF interference trouble
[0 (10)] or [10]
Module supervision loss
[1]
MG-2WPGM
[2]
Keypad bus (Panel reset will not clear this trouble, clear it in
section
[955]
)
[3]
ZX8 bus module
[4]
RTX3 bus module
[5]
Wireless keypad supervision failure
[6]
Wireless repeater supervision failure
[16]
Keypad fault (MG32LED/MG32LRF only)
[
SLEEP
]
Keypad fault (MG10LEDV/H only)
Содержание SP5500
Страница 51: ...Magellan Spectra SP 51 Hardware Connections Single Zone Inputs...
Страница 52: ...52 Programming Guide Advanced Technology Zone ATZ Connections...
Страница 56: ...56 Programming Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Страница 63: ......
Страница 64: ...paradox com Printed in Canada 07 2007 MGSP EP11...