Magellan / Spectra SP
21
Refer to the
Installer Quick Menu
on page 3 for alternate PGM programming.
Programmable Output Options
48 = Special
(Partition 1 only)
00 = System power up
01 = Reporting test
02 = Software log on
03 = Software log off
04 = Installer in programming mode
05 = Installer exited programming mode
06 = Maintenance in programming mode
07 = Maintenance exited programming mode
08 = Closing delinquency delay elapsed
99 = Any special event
49 = Low battery on zone
01 to 32 = Zone number
99 = Any zone number
50 = Low battery on zone restore
51 = Zone supervision trouble
52 = Zone supervision restore
53 = Wireless module supervision trouble (Partition 1 only)
54 = Wireless module supervision restore (Partition 1 only)
55 = Wireless module tamper trouble (Partition 1 only)
56 = Wireless module tamper restore (Partition 1 only)
01 to 16 = Output
17 to 18 = Wireless repeater
19 to 22 = Wireless keypad
57 = Non-medical alarm (paramedic)
01 to 32 = User number
99 = Any user number
58 = Zone forced
01 to 32 = Zone number
99 = Any zone number
59 = Zone included
Default:
Bold
Section:
PGM 1
[261]
PGM 2
[262]
PGM 3
[263]
PGM 4
[264]
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[1]
PGM Base Time (Off=Sec; On=Min)
N
N
N
N
[2]
PGM State (Off=N.O., On=N.C.)
N
N
N
N
[3]
PGM Supervision
N
N
N
N
[4]
PGM Activation Mode (Off=Steady, On=Pulse)
N
N
N
N
[5]
PGM Pulse once every 30 seconds if armed
N
N
N
N
[6]
PGM Pulse on any alarm
N
N
N
N
[7]
PGM Pulse on any alarm -
OFF= Partition 1 On= Partition 2
N
N
N
N
[8]
N/A
N/A
N/A
N/A N/A
N/A N/A
N/A N/A
Default:
Bold
Section:
PGM 5
[265]
PGM 6
[266]
PGM 7
[267]
PGM 8
[268]
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[1]
PGM Base Time (Off=Sec.; On=Min.)
N
N
N
N
[2]
PGM State (Off=N.O., On= N.C.)
N
N
N
N
[3]
PGM Supervision
N
N
N
N
[4]
PGM Activation
Mode (Off=Steady, ON=Pulse)
N
N
N
N
[5]
PGM Pulse once every 30 seconds if armed
N
N
N
N
[6]
PGM Pulse on any alarm
N
N
N
N
[7]
PGM Pulse on any alarm -
OFF= Partition 1 On= Partition 2
N
N
N
N
[8]
N/A
N/A
N/A N/A
N/A N/A
N/A N/A
N/A
Event Group #
Sub-group #
Содержание SP5500
Страница 51: ...Magellan Spectra SP 51 Hardware Connections Single Zone Inputs...
Страница 52: ...52 Programming Guide Advanced Technology Zone ATZ Connections...
Страница 56: ...56 Programming Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Страница 63: ......
Страница 64: ...paradox com Printed in Canada 07 2007 MGSP EP11...