Activation Key, Activation Status
o
Used for licensing of driver
Driver Version
o
Current Driver version install on project
Driver Information
o
Current Device State (Online or Offline, Failed to Check in)
Debug Mode (Default: Off)
o
Used to view the driver log. Debug will turn off automatically after 15 minutes
Polling Timer (default: 120)
o
Time (in seconds) the driver checks in with the Paradox for RS232 communication
o
Values can be: 0 - 1500 Seconds. 0 = Polling Timer disabled
Number of Zones (default: 0)
o
Required for driver setup.
o
Number of zone in Paradox panel.
o
Values can be: 0 - 192. Note: changing this number will remove all existing connections.
Number of Partitions (default: 1)
o
Required for driver setup
o
Number of partitions being used on Paradox panel.
o
Values can be 1 - 8. Note: changing this number will remove all existing connections.
Partition - Settings
o Choose which partition settings you want to edit. Set Defaults
will default all partitions settings (next 4 options)
Partition - ZonesInPartition
o list of zones attached to that particular partition.
o Default: all zones in project.
Partition - Label
o Label of Partition.
o
Default: Area 1, Area 2, Area 3, etc…
Partition - ExitDelay
o exit delay for partition in seconds
o
Default: 60 (seconds)