Paradox PARAKEY Скачать руководство пользователя страница 12

Section [35] - Feature Select: [2]
When a remote control-activated panic alarm is
generated (see section 4.3.3), the Parakey can perform
one of two actions:

Key [2] OFF = Panics generated from the remote control

will only toggle the enabled PGM output
(see section 4.4).

Key [2] ON = Panics generated from the remote control

will toggle any enabled PGM outputs (see
section 4.4) and sends the Panic
command to the control panel generating
a Panic alarm on the control panel.

Warranty
The Seller warrants its products to be free from defects in
materials and workmanship under normal use for a
period of one year. Except as specifically stated herein,
all express or implied warranties whatsoever, statutory or
otherwise, including without limitation, any implied
warranty of merchantability and fitness for a particular
purpose, are expressly excluded. Because Seller does
not install or connect the products and because the
products may be used in conjunction with products not
manufactured by Seller. Seller cannot guarantee the
performance of the security system. Seller obligation and
liability under this warranty is expressly limited to
repairing or replacing, at Seller's option, any product not
meeting the specifications. In no event shall the Seller be
liable to the buyer or any other person for any loss or
damages whether direct or indirect or consequential or
incidental, including without limitation, any damages for
lost profits stolen goods, or claims by any other party,
caused by defective goods or otherwise arising from the
improper, incorrect or otherwise faulty installation or use
of the merchandise sold.

FCC Warnings
This device complies with part 15 of the FCC Rules.
Operation is subject to the followintg two conditions: (1)
this device may not cause interference, and (2) this
device must accept any interference, including
interference that may cause undesired operation of the
device.

4.8 Panic Option

20

Содержание PARAKEY

Страница 1: ...Remote Arming Module V1 10 318MHz 433MHz With KEELOQ high security code encryption Installer s Guide PARKEI 02 i i...

Страница 2: ...2 5 Programmable Outputs PGMs 6 2 6 Hand Held Remote Control 7 2 7 System Reset 8 HOW TO PROGRAM 11 PROGRAMMING THE SYSTEM 13 4 1 Access Code Length 13 4 2 Installer Code 13 4 3 User Parameters 13 4 3...

Страница 3: ...imple user friendly programming Supports 8 User Codes each linked to a unique RF Code 2 or 4 button remote control Encrypted RF codes for additional security Does not use DIP switch programming 4 prog...

Страница 4: ...hen used in conjunction with any Paradox Esprit Series Control Panel the auxiliary terminals 12VDC of the control panel may power the Parakey Receiving Module as shown in figure 3 If using an external...

Страница 5: ...age door when button 1 is pressed on the remote control Please refer to figure 1 and section 4 for more information There are two types of hand held PARAKEY remote controls There is a 2 button RF tran...

Страница 6: ...vice versa To execute a system reset perform the following 1 Remove the power connections 12 GND from the receiver 2 Press and hold the PROG button and re connect the power connections to the receiver...

Страница 7: ...illuminate If at any time you wait longer than 2 minutes between each key entry the Parakey will automatically exit the Programming Mode 3 1 2 Step 2 Key in Installer Code Press ENTER and key in the I...

Страница 8: ...etting Turn the keys on off by pressing the appropriate key until the desired options are set and press the ENTER key The keypad will emit a confirmation beep and the Parakey will save and exit the se...

Страница 9: ...ively figure 5 The User Access Code programmed in the Parakey must be the same as a User Access Code programmed in the Paradox Esprit Series Control Panel 4 3 2 Remote Control Assignment Sections 09 t...

Страница 10: ...ressing the corresponding button will activate toggle any PGMs defined by the Button PGM Options section 4 7 Default all ON Key 4 OFF Disabled ON Button 1 PGM Enabled Key 5 OFF Disabled ON Button 2 PG...

Страница 11: ...specified period of time At the end of this period the output will return to its normal state Each PGM output can be programmed with a separate output timer In the section corresponding to the desire...

Страница 12: ...ot install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller ob...

Отзывы: