Section [25]
Key [0] ON = No output on panic alarm
Key [1] ON = Toggle output 1 on panic alarm
Key [2] ON = Toggle output 2 on panic alarm
Key [3] ON = Toggle output 3 on panic alarm (default)
Key [4] ON = Toggle output 4 on panic alarm
Section [26] - Decimal Select: [0] to [4]
When a remote control-activated panic alarm is
generated (see section 4.3.3), the Parakey can ignore
any incoming RF signals for a specified period. This
prevents an aggressor from disarming the system in case
of a panic situation. In section [26], select only one:
Section [26]
Key [0] ON = No signal lock-out on panic alarm (default)
Key [1] ON = 30 second signal lockout on panic alarm
Key [2] ON = 60 second signal lockout on panic alarm
Key [3] ON = 90 second signal lockout on panic alarm
Key [4] ON = 120 second signal lockout on panic alarm
Section [27] to [30] - Decimal Select: [0] to [8]
When any of the PGM outputs are activated (see section
4.3.3 & 4.4), the Parakey can latch the output in its
opposite state until the output is toggled again or for a
specified period of time. At the end of this period, the
output will return to its normal state. Each PGM output
can be programmed with a separate output timer. In the
section corresponding to the desired PGM output, where
sections [27] to [30] represent PGM outputs 1 through 4
respectively, select the desired output timer.
Key [0] ON = Latched
Key [5] ON = 40 sec.
Key [1] ON = 1 sec.
Key [6] ON = 60 sec.
Key [2] ON = 5 sec. (default)
Key [7] ON = 2 min.
Key [3] ON = 10 sec.
Key [8] ON = 4 min.
Key [4] ON = 20 sec.
Sections [31] to [34] - Feature Select: [1] to [4]
This feature allows you to determine which PGM outputs
a PGM enabled button will activate (see section 4.3.3).
Please note that this feature is a global feature.
For example, if button 1 is programmed to toggle
PGM outputs 1 and 2, then button 1 on all the
remote controls will toggle PGM outputs 1 and 2.
In the section corresponding to the desired button, where
sections [31] to [34] represent buttons 1 through 4
respectively, select which outputs will be triggered.
OFF
Key
ON
Disabled
[1]
Activate Output 1
Disabled
[2]
Activate Output 2
Disabled
[3]
Activate Output 3
Disabled
[4]
Activate Output 4
4.7 Button PGM Options
4.6 PGM Output Timing
4.5 Panic Lockout Timer