Remote Arming Module V1.10
318MHz/433MHz
With
KEELOQ high-security code encryption
Installer’s Guide
PARKEI-02
i
Страница 1: ...Remote Arming Module V1 10 318MHz 433MHz With KEELOQ high security code encryption Installer s Guide PARKEI 02 i i...
Страница 2: ...2 5 Programmable Outputs PGMs 6 2 6 Hand Held Remote Control 7 2 7 System Reset 8 HOW TO PROGRAM 11 PROGRAMMING THE SYSTEM 13 4 1 Access Code Length 13 4 2 Installer Code 13 4 3 User Parameters 13 4 3...
Страница 3: ...imple user friendly programming Supports 8 User Codes each linked to a unique RF Code 2 or 4 button remote control Encrypted RF codes for additional security Does not use DIP switch programming 4 prog...
Страница 4: ...hen used in conjunction with any Paradox Esprit Series Control Panel the auxiliary terminals 12VDC of the control panel may power the Parakey Receiving Module as shown in figure 3 If using an external...
Страница 5: ...age door when button 1 is pressed on the remote control Please refer to figure 1 and section 4 for more information There are two types of hand held PARAKEY remote controls There is a 2 button RF tran...
Страница 6: ...vice versa To execute a system reset perform the following 1 Remove the power connections 12 GND from the receiver 2 Press and hold the PROG button and re connect the power connections to the receiver...
Страница 7: ...illuminate If at any time you wait longer than 2 minutes between each key entry the Parakey will automatically exit the Programming Mode 3 1 2 Step 2 Key in Installer Code Press ENTER and key in the I...
Страница 8: ...etting Turn the keys on off by pressing the appropriate key until the desired options are set and press the ENTER key The keypad will emit a confirmation beep and the Parakey will save and exit the se...
Страница 9: ...ively figure 5 The User Access Code programmed in the Parakey must be the same as a User Access Code programmed in the Paradox Esprit Series Control Panel 4 3 2 Remote Control Assignment Sections 09 t...
Страница 10: ...ressing the corresponding button will activate toggle any PGMs defined by the Button PGM Options section 4 7 Default all ON Key 4 OFF Disabled ON Button 1 PGM Enabled Key 5 OFF Disabled ON Button 2 PG...
Страница 11: ...specified period of time At the end of this period the output will return to its normal state Each PGM output can be programmed with a separate output timer In the section corresponding to the desire...
Страница 12: ...ot install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller ob...