HV8D - page 2

Wiring

Related Topics

Specifications

Installation / Wiring 

(see Imperial System Guide)

DIN Rail Enclosure

System Diagrams and Wiring Tips

Wire Gauge Selection

Features

Shutter Calibration (see page 3)

Bi-directional Locate Feature (see page 4)

Remote Firmware Upgrade (see page 4)

Applications 

(see Imperial System Guide)

Shutters

Light Control

Sprinklers

Macros

BabyWare 

(see Imperial System Guide)

BabyWare

Operating  
voltage

120Vac to 230Vac (nominal)

Frequency

50 to 60Hz

Maximum load

10A

 for incandescent lamps, fluorescent lamps, 

electronic step-down converters (halogen), and 
iron-core transformers (extra low-voltage 
incandescent lamps).

8A

 for 0.5hp motors.

Multibus

900m (3,000ft) 

Current 
Consumption

min. 40mA 
max. 500mA

No. of inputs

6 (4 emergency stop and 2 global up/down)

Dimensions

DIN9: 16cm X 10cm X 6cm (6.3” X 4” X 2.5”)

Operating 
Temperature

-10ºC to 50ºC 
14ºF to 122ºF

1

Relay Mode 

If, in BabyWare, the output is set to 
Light, Sprinkler, or Custom, it will 
function as a standard relay output. 
See "Relay vs. Shutter Mode” on 
page 3.

2

Shutter Mode 

If, in BabyWare, the output is set to 
Shutter, the related outputs (Up/
Down) will be paired for shutter 
operation. See "Relay vs. Shutter 
Mode” on page 3.

3

Local Bus (Future Use)

Imperial Dimmer Wall Switches that 
are connected to the local bus are 
independent from the rest of the 
system and can control the shutter 
outputs. This ensures continued 
operation of the outputs should the 
Multibus stop for any reason. This 
feature also provides the option to add 
shutter control without the need of the 
Imperial system. If in relay mode, only 
the odd numbered outputs can be 
controlled (e.g. 1, 3, 5, 7).

4

Global Up/Down

By connecting a 2-way momentary 
switch, all connected shutter motors 
can be activated together.

5

Emergency Stop 

It includes an emergency stop input 
per shutter motor to connect a device, 
such as an IR beam, to stop the motor 
when motion is detected. The motor 
will also stop when the dial on the 
dimmer wall switch is pushed.

AC power line

Shutter
 Motor

N
Up
Down

YEL
GRN
BLK
RED

YEL
GRN
BLK
RED

Global 
Up / Down

Emergency

Stop

Br

eak

er

Br

eak

er

L

N

L

N

MODULE BREAKER NO:

HV8D

BUS INPUT

LOCAL BUS

1

2

3

5

4

Imperial Multibus

GRN3

Controls 
RLY5/RLY6

GRN1

Controls 
RLY1

By default, using the Global 

button on any dimmer wall switch 

connected tot he Local Bus will 

control all outputs that are in 

Shutter Mode

WARNING:
It is highly recommended to power the module using an 

external source (e.g. PS100 or PS27D) and NOT from the 

Multibus to avoid flickering of the output in case of a loss 

of bus power. Flickering might cause damage to electrical 

appliances connected to the outputs.

Local bus 

(future use)