Esprit E55 / E65
13
Communication Programming
[800]
Dialer Options
Option
OFF
ON
[1]+2]*
N
See Table
N
See Table
[3]*
Switch to pulse on 5
th
attempt
Disabled
N
Enabled
[4]
Alternate dial
Disabled
N
Enabled
[5]*
Force dial (must be enabled to comply with TBR-21)
N
Disabled
Enabled
[6]*
DTMF dialing
N
Disabled
Enabled
[7]*
Pulse ratio
N
1:2
1:1.5
[8]
Reporting
Dialer activated
N
Dialer deactivated
* E55 only
[801]
Dialer Options
Option
OFF
ON
[1]
Report system disarming
N
Always
After alarm
[2]
Report zone restore
Bell cutoff
N
Zone closure
[3]+[4]
[5]
Contact ID Override
N
Disabled
N
CID defaults / slow
format custom
[802]
Event Call Direction Options 1
Option
OFF
ON
[1]
Call tel. #1 for arm/disarm report codes
N
Disabled
Enabled
[2]
Call tel. #2 for arm/disarm report codes
N
Disabled
Enabled
[3]
Call pager for arm/disarm report codes
Disabled
N
Enabled
[5]
Call tel. #1 for alarm/restore report codes
N
Disabled
Enabled
[6]
Call tel. #2 for alarm/restore report codes
N
Disabled
Enabled
[7]
Call pager for alarm/restore report codes
N
Disabled
Enabled
Telephone
Line Monitoring (TLM)
Options
[1]
[2]
OFF
OFF
Disabled
OFF
ON
When disarmed: Trouble only
When armed: Trouble only
ON
OFF
When disarmed: Trouble only
When armed: Audible alarm
ON
ON
Silent alarms become Audible alarm
Auto-Test Report Transmission Options
[3]
[4]
Auto-Test Report Transmission Options
OFF
OFF
Transmit the test report code every time the days programmed in section
[840]
have elapsed at the time programmed in
section
[850]
(default).
OFF
ON
When disarmed: Transmit test report code every time the time programmed in section
[852]
has elapsed. When armed:
Transmit test report code every time the time programmed in section
[851]
has elapsed.
ON
OFF
The control panel will transmit the test report code every hour on the minute value programmed in section
[850]
(the last
two digits). Note that the first two digits of section
[850]
will be ignored.
E.g. If 10:25 was programmed into section [850],
the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON
ON
The test report code will be transmitted when any of the conditions of the second and third options listed above (options
[3]
= OFF and
[4]
= ON / options
[3]
= ON and
[4]
= OFF) are met.
Содержание Esprit E55
Страница 36: ...34 Programming Guide Advanced Technology Zone ATZ Connections...
Страница 47: ......