background image

 

 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 1 of 8

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Studio High Performance 
Keypad

IS-0425 REV. A

 

  ©Copyright 2009 by On-Q/Legrand All Rights Reserved. 

1.   Introduction  

 

The lyriQ™ Studio High Performance Keypad, P/N AU5010-xx 

(see 

Figure 1

),

 is 

an integral part of the lyriQ™ Multi-Room Audio System. It is a component which, 
when combined with other essential components (a Source Input Unit, Distribution 
Module and Speakers) and your source equipment (receiver, CD player, etc.), 
creates a versatile whole-house audio system that will fill your rooms with high-
quality sound for years to come. It uses Category 5 wiring to distribute audio 
signals, control information and IR for remote control. The High Performance 
Keypad has two on-board 20 Watt per channel class D amplifiers to provide a rich 
level of clean sound even in large room applications. It also contains a full set of 
features, including the ability to control all other keypad volume controls in the 
house. Build a system that accommodates the needs of any space by combining 
the lyriQ™ Studio High Performance Keypad with the lyriQ™ Studio Keypad (P/N 
AU5009-xx) in the same system. The AU5010-xx is available in white (-WH), light 
almond (-LA), titanium (-TI), or gloss black (-GB). 

 

2.   Description  

 

The front panel of the lyriQ™ Studio High Performance Keypad, PN AU5010-xx 

(see 

Figure 1

),

 looks almost identical to the standard lyriQ™ Studio Keypad (AU5009-xx). It 

also has push buttons for STANDBY (backlit with red LED when in Standby Mode), for 
MUTE (backlit with red LEDs, when Mute function is selected), VOLUME UP/DOWN 
(with six associated blue Volume Bar Graph LEDs), SOURCE SELECT (with six blue 
Source Selection LEDs), and WHOLE HOUSE (backlit with white LEDs when not 
selected and with flashing blue/white LEDs when Whole House function is selected). 
There is also an IR target window. The visual cue from the front panel that this is a 
High Performance Volume Control are the parenthesis surrounding the music note on 
the lower left corner of the display area. 
 

NOTE: lyriQ™ Keypads are recommended for indoor use only. 

 
On the rear of the lyriQ™ Studio High Performance Keypad (see 

Figure 2

) the Category 

5 connection is an RJ45 jack (J1). The TB2 speaker output connections (left and right, 
plus and minus) are spring loaded and designed to support up to 14 gauge wire. The TB3 
Line Out connections (plus and minus) are also spring loaded and designed to support up 
to 14 gauge wire. This mono-summed output is designed for powered sub-woofers and 
as such is filtered through an 80Hz low pass filter. The other terminal block on the rear 
(TB1) is used for powering the keypad. Up to 14 gauge speaker wire may be used for this 
purpose, and this speaker wire (two or four conductor) is run from a power distribution 
module (P/N AU1001) in the enclosure to the Keypad. We recommend 16/4 speaker 
wire, since it is available paired with Category 5 from a variety of sources. Again, the TB1 
connections are spring loaded (plus and minus) with the two plus connections on the red 
portion of TB1 and the two minus connections on the black portion of TB1. For ease of 
installation, connect the red wire and white wire to the red (plus) portion of TB1 and the 
black and green wire to the black (minus) portion of TB1. 
  

Figure 1 

 

Figure 2 

Содержание On Q lyriQ

Страница 1: ...by Mode for MUTE backlit with red LEDs when Mute function is selected VOLUME UP DOWN with six associated blue Volume Bar Graph LEDs SOURCE SELECT with six blue Source Selection LEDs and WHOLE HOUSE backlit with white LEDs when not selected and with flashing blue white LEDs when Whole House function is selected There is also an IR target window The visual cue from the front panel that this is a Hig...

Страница 2: ...ould be run from the enclosure location to a single gang outlet box at each Volume Control location typically mounted at electrical light switch height B Trim out steps 1 Connect the volume control by terminating the pre wired Category 5 cable from the enclosure with an RJ45 plug following the T568A wiring standard and insert this plug into jack J1 see Figure 2 2 For the power connection TB1 strip...

Страница 3: ...r wire power cable that was run to each volume control location strip 3 8 of insulation from each of the four conductors and insert the red and white wires into the red plus portion of TB1 Insert the stripped black and green wires into the black minus portion of TB1 NOTE As noted before Electricians may prefer to think of the black and red wires as plus and the green and white wires as minus That ...

Страница 4: ...rformance Keypad IS 0425 REV A Copyright 2009 by On Q Legrand All Rights Reserved 5 Keypad Mounting check all connections and test the system s operation before installing the volume controls into the wall Use the included screws to install the volume control and wall plate into the single gang box NOTE A 20 cubic inch or larger single gang box is recommended Figure 4 ...

Страница 5: ...ocal Sources If more than one Local Source is connected they are indicated by L and 2 NOTE Upon source change volume mutes and then ramps back up to prior volume setting automatically D VOLUME Steps Keypad or Remote Press VOLUME Up or VOLUME Down button 36 steps E MUTE Keypad or Remote Press MUTE button to toggle Mute On or Off NOTE When returning from MUTE volume control will ramp to pre mute or ...

Страница 6: ...sts will take about 15 seconds and about 2 seconds after that Hitting any button during the test will interrupt the test and the Keypad will operate as normal 5 Important Safety Precautions Read the instructions that are included with all associated lyriQ Audio products before installing any single component If you are unsure of any of the installation procedures contact On Q Legrand Technical Sup...

Страница 7: ...ed on it will be set to its last volume MAXIMUM VOLUME Sets the maximum allowed volume for this KVC SPECIFIED VOLUME DEFAULT The displayed volume setting is the maximum volume IR TARGET ENABLED IR REPEAT ENABLED DEFAULT The KVC will process received IR commands and repeat any received IR throught the system IR TARGET ENABLED IR REPEAT DISABLED The KVC will process received IR commands but will NOT...

Страница 8: ...tem The KVC allows for different patterns based on the selected source 1 4 The pattern selected here will be for the source that was selected when Installer Setup Mode was activated 56 kHz FREQUENCY This KVC will repeat IR commands using a 56 kHz pattern ENABLED DEFAULT This KVC will automatically power off after 20 minutes of audio inactivity AUTOMATIC POWER OFF Determines whether this KVC will a...