Silent operation:
When using the panic keys, the control panel will emit a single confirmation beep. The control panel will transmit the event codes
programmed at addresses 513, 514 and 515. The alarm will latch (no audible alarm) and the
light on the keypad will flash until
the system is disarmed by a valid user code.
Audible operation:
Audible operation is the same as silent operation, except the alarm output (bell/siren) will activate until the system is disarmed by
a valid user code or until the Bell Cut-Off Time (see page 34) elapses.
Fire operation:
Fire operation is the same as audible operation except that bell/siren output will be pulsed (intermittent ON/OFF).
10.5
Panel Time
Key Access Programming
D
Key
[
MEM
]
To program the current time into the control panel press:
[
ENTER
]
+ (Installer, Master, or User code 1) +
[
MEM
]
+ 2 digits representing hours (00 to 23) + 2 digits representing minutes (00 to 59)
10.6
Time Correction
Streamline - Section 09
D
Hex Programming - Address 037 (2nd digit)
If you notice a gain or loss in the control panel time, calculate the average gain or loss per day; select the "opposite" amount from
the Time Correction table in order to automatically correct the time setting every 24 hours.
Example: The control panel loses 4 minutes per month, representing an average loss of 8 seconds per day. Therefore, program
[2]
(plus 8 seconds) as the second digit in address 037 to compensate for the 8-second loss.
10.7
Tamper/Wire Fault Recognition Options
Feature Select Programming
D
Address 088; Keys
[0]
and
[
STAY
]
Default: Disabled
If the control panel detects an open or a short on a zone when the system is armed, regardless of the tamper/wire settings it will
always generate an alarm and trouble indicator (key
[9]
). Alarms will be audible or silent depending on individual zone definitions.
If an open or short occurs on a disarmed system, the control panel will generate an incident depending on the following settings.
Tamper/Wire disabled
Tamper/wiring failure recognition is disabled. Not permitted on UL listed systems.
Trouble enabled
Tamper/wiring failure will generate a trouble indicator (key
[9]
) and a trouble report code (see
the system is disarmed.
Silent alarm enabled
Tamper/wiring failure will generate a trouble indicator (key
[9]
on page 22) and a silent
alarm (no bells/sirens).
Audible alarm enabled
Tamper/wiring failure will generate a trouble indicator (key
[9]
), a trouble report code (see
on page 22) and an
audible alarm.
When the zone definition is 24Hr, the tamper definition follows the audible/silent alarm definition of the 24Hr
zone.
Table 16: Time Correction Table
(address 037 2nd digit)
[2
ND
]
- No adjustment
[4]
- Plus 16 seconds
[8]
- Minus 4 seconds
[
AWAY
]/[
FORCE
]
- Minus 20 seconds
[1]
- Plus 4 seconds
[5]
- Plus 20 seconds
[9]
- Minus 8 seconds
[
BYP
]
- Minus 24 seconds
[2]
- Plus 8 seconds
[6]
- Plus 24 seconds
[0]
- Minus 12 seconds
[
MEM
]
- Minus 28 seconds
[3]
- Plus 12 seconds
[7]
- Plus 28 seconds
[
STAY
]
- Minus 16 seconds
[
TBL
/
TRBL
]
- Minus 32 seconds
Table 17: Tamper Recognition Option
Key [10 (0)]
Key [
STAY
]
OFF
OFF
- Tamper/Wire Fault disabled
OFF
ON
- Trouble Indicator enabled
ON
OFF
- Silent Alarm enabled
ON
ON
- Audible Alarm enabled