DIGIPLEX SERIES
39
SOFTWARE RESET
Performing a software reset will set certain parameters to default values. To do so:
1) Make sure the "RESET" jumper on the control panel is on.
2) Enter Programming Mode (see page 2).
3) Enter the 3-digit [
SECTION
] corresponding to the software reset you wish to perform:
Section #
Description
[970]
Entering this section will reset all programmable sections from
[001]
to
[990]
to factory default values.
[975]
Entering this section will reset all Zone and Keyswitch programming sections from
[001]
to
[156]
to default.
[976]
Entering this section will reset all programmable timers in sections
[200]
to
[274]
to default values.
[977]
Entering this section will reset all PGM and option sections from
[400]
to
[522]
to default values.
[978]
Entering this section will reset all communication sections from
[523]
to
[718]
to default values.
[979]
Entering this section will reset all user code sections from
[802]
to
[864]
to default values.
Section #
Data
Description
Default Value (notes)
[990]
___/___/___ (147=lock, 000=unlock)
LOCK
INSTALLER
CODE
000
INSTALLER QUICK FUNCTION KEYS
Press and hold the
[0]
key and key in the
[
INSTALLER
CODE
]
. Then press
one of the following function keys:
[
STAY
]
-
Test Report:
Sends the "Test Report" report code programmed in section
[717]
to the central station.
[
FORCE
]
-
Call WinLoad Software:
Will dial the PC telephone number programmed in section
[560]
in order to
initiate communication with a computer using the WinLoad Upload/Download software.
[
ARM
]
-
Answer WinLoad Software:
Will force the control panel to answer a call made by the Central Monitoring
Station that is using the WinLoad upload/download software.
[
DISARM
]
-
Cancel Communication:
Cancels all communication with the WinLoad Software or with the Central
Station until the next reportable event.
[
MEM
]
-
Installer Test Mode:
The installer test mode will allow you to perform walk tests where the bell or siren will squawk
to indicate opened zones. Press [
MEM
] again to exit. Partitions can not be armed if the Installer Test Mode is enabled.
[
TRBL
]
-
Start Module Scan:
The keypad will display the serial number of each module on the bus.
Содержание Digiplex V2.14
Страница 1: ...Digiplex System V2 14 V2 2ACC Control Panel Programming Guide...
Страница 2: ......
Страница 42: ...40 PROGRAMMING GUIDE Hardware Connections SINGLE ZONE INPUTS ATZ DOUBLE ZONE INPUTS...
Страница 43: ...DIGIPLEX SERIES 41 CONNECTING A ZX4 EXPANDER MODULE FIRE ZONE KEYSWITCH AND PGM CONNECTIONS...
Страница 44: ...42 PROGRAMMING GUIDE DIGIPLEX PCB LAYOUT...
Страница 47: ......
Страница 48: ......