DIGIPLEX SERIES
37
Other Settings and Modes
Section #
Data
Description
Default Value (notes)
[800]
___/___/___/___/___/___
INSTALLER
CODE
000000
[801] to [896]
Program User Code Options and Partition Assignment for users 001 to 096. Refer to the appropriate keypad
User’s Manual for instructions on how certain users can also program these values. Only control panels with the
Access Control option using keypads with versions 1.3 or higher will support more than 64 user codes.
Section #
Description
[900]
Display Serial Number of Control Panel and All Modules Connected to the Bus:
With the LCD Keypad:
After entering section
[900]
, the keypad will display the eight digit serial number of the
control panel. Use the
[
p
]
and
[
q
q
]
keys to scroll through the serial number of each module connected to the bus.
With the LED Keypads:
After entering section
[900]
, the control panel’s serial number will illuminate one number
at a time as you press the
[
p
]
key (
[10]
LED represents zero). The keypad will emit a confirmation beep to
indicate that it is now displaying the serial number of the next module connected to the bus.
[950]
Reset System Master Code:
To reset the System Master Code
to 123456, put the “reset” jumper to on and
enter section [950]. You do not have to remove power from the control panel.
[951]
Module Reset:
Reset a bus module’s programmed contents to default by entering its serial number.
[952]
Locate/Unlocate Module:
Locate a specific module (e.g. detector, zone expander, etc.) connected to the bus
by entering the module's serial number. The green "
LOCATE
" LED on the module will begin to flash until the serial
number is re-entered or the appropriate "tamper" or "unlocate" switch on the module is pressed.
Содержание Digiplex V2.14
Страница 1: ...Digiplex System V2 14 V2 2ACC Control Panel Programming Guide...
Страница 2: ......
Страница 42: ...40 PROGRAMMING GUIDE Hardware Connections SINGLE ZONE INPUTS ATZ DOUBLE ZONE INPUTS...
Страница 43: ...DIGIPLEX SERIES 41 CONNECTING A ZX4 EXPANDER MODULE FIRE ZONE KEYSWITCH AND PGM CONNECTIONS...
Страница 44: ...42 PROGRAMMING GUIDE DIGIPLEX PCB LAYOUT...
Страница 47: ......
Страница 48: ......