Digiplex EVO • Programming Guide
Version 7.11
Programmable Outputs | 21
Programmable Outputs
PGM Programming
1.
Enter section
[0901]
-
[0932]
.
2.
Enter the eight-digit module or panel serial number and three-digit output number.
3.
Enter the three-digit Event Group, Feature Group, Start #, and End # for PGM activation.
4.
Enter the three-digit Event Group, Feature Group, Start # and End # for PGM deactivation.
5.
Define the PGM Delay value (001 to 255 x 1 sec./min.). Default is set to 15 minutes.
6.
Set your PGM options. Refer to table 15.
Event and Feature Groups
Notes for Table 16
Table 15: PGM Options
Option
Description
PGM #
OFF
ON
1
PGM deactivation after (OFF = deactivation event; ON = PGM timer)
2
PGM base time (OFF = seconds; ON = minutes)
3
Flexible PGM deactivation option (OFF = PGM timer only; ON = PGM timer and/
or deactivation event)
4
PGM initial state (OFF = normally open; ON = normally closed)
5
PGM Time base ( OFF = follow options 2, ON = hour)
6 to 8
Future use
-
-
000 = Occurs in all partitions enabled in the system (refer to section
[3031]
, in
001 = Partition 1
002 = Partition 2
003 = Partition 3
004 = Partition 4
255 = Occurs in at least one partition enabled in the system
005 = Partition 5
006 = Partition 6
007 = Partition 7
008 = Partition 8
Table 16: List of Event and Feature Groups
A
Event Group
Event
B
Feature Group
Feature
C
Start #
D
End #
000
Zone is OK
000
255 = any zone #
Zone numbers
001 to 192
001 to 192
001
Zone is open
001 to 192
001 to 192
002
Zone is tampered
001 to 192
001 to 192
003
Zone is in fire loop trouble
001 to 192
001 to 192
004
Non-reportable event
000
TLM trouble
000
000
Содержание Digiplex EVO EVO192 V7.11
Страница 1: ...Digiplex EVO High Security and Access System EVO192 V7 11 Programming Guide...
Страница 79: ......