 = Default setting

Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.

Warranty

For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all 
warranty terms and conditions.

We strongly advise that you review and take into consideration the “Limitations of Alarm Systems” document available on our website at 

http://paradox.com/Terms/

© 2003-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 
5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply. 

Digiplex EVO is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. 

Technical Support

For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. 
For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. 
Please feel free to visit our website at www.paradox.com.

SECTION [001]: Partition Assignment

SECTION [002]: General Options 1

Option

OFF

ON            

Option

OFF

ON            

[1]

Partition 1

 

N

 Disabled

U

 Enabled

[1]

Tamper Input

U

 Disabled

 

N

 Enabled

[2]

Partition 2

 

N

 Disabled

U

 Enabled

[2]

Battery Charging Current

U

 350mA

 

N

 850mA

[3]

Partition 3

 

N

 Disabled

U

 Enabled

[3]

Reader’s red LED to follow partition’s 
status

 

N

 Disabled

U

 Enabled

[4]

Partition 4

 

N

 Disabled

U

 Enabled

[4]

Reader’s beeping to follow partition’s 
status when option [3] is ON

 

N

 Disabled

U

 Enabled

[5]

Partition 5

 

N

 Disabled

U

 Enabled

[5]

Card activates door unlocked schedule

 

N

 Disabled

U

 Enabled

[6]

Partition 6

 

N

 Disabled

U

 Enabled

[6]

Door will relock 

U

 Imme-

diately

 

N

 When

closed

[7]

Partition 7

 

N

 Disabled

U

 Enabled

[7]

Reader’s green LED for Access 
Granted

 

N

 Disabled

U

 Enabled

[8]

Partition 8

 

N

 Disabled

U

 Enabled

[8]

Unlock on Request for Exit (REX)

 

N

 Disabled

U

 Enabled

SECTION [003]: General Options 2

SECTION [004]: PGM Options

Option

OFF

ON            

Option

OFF

ON            

[1]

Door Left Open Alarm

U

 Disabled

 

N

 Enabled

[1]

PGM Deactivation After

U

 Deactiva-

tion Event

 

N

 PGM Timer

[2]

Door Left Open Pre-alarm

 

N

 Disabled

U

 Enabled

[2]

PGM Normal State

U

 N.O.

 

N

 N.C.

[3]

Door Left Open Alarm

 

N

 Silent

U

 Audible

[3]

PGM Base Time

U

 1 second

 

N

 1 minute

[4]

Door Left Open Alarm follows

U

 Alarm

Restore

 

N

 Beep

Timer

[4] & [5] Special

[4]

[5]

[5]

Door Forced Open Alarm

U

 Disabled

 

N

 Enabled

N

 Card Only

N

 PIN Only

N

 Card and PIN

U

 Card or PIN

OFF
ON
OFF
ON

OFF
OFF
ON
ON

[6]

Door Forced Alarm 

 

N

 Silent

U

 Audible

[7]

Door Forced Alarm follows

U

 Alarm

Restore

 

N

 Beep

Timer

[8]

Reader Access Feedback

N

Visual

U

 Visual &

audible

[6]

Reader Locate Feedback

U

 Visual

 

N

 Visual &

audible

[7]

Unlock Door on Fire Alarm

U

 Disabled

 

N

 Enabled

[8]

AC and Battery Supervision

U

 Enabled

 

N

 Disabled

Section

Data

Description

Default

[005]

__/__/__ (000 to 255 x 1 minute; 000 = Instant)

AC failure report delay

030

[006]

__/__/__ (001 to 255 seconds)

Door Unlocked Period 

005

[007]

__/__/__ (001 to 255 seconds added to section [006])

Door Unlocked Period extension

015

[008]

__/__/__ (001 to 255 seconds)

Door Left Open Interval

060

[009]

__/__/__ (001 to 255 seconds)
Time to start pre-alarm before alarm is triggered

Door Left Open Pre-Alarm Timer

015

[010]

__/__/__ (001 to 255 seconds)

Beep timer for Door Left Open Alarm

005

[011]

__/__/__ (001 to 255 seconds)

Beep timer for Door Forced Open alarm

005

[012]

__/__/__ (000 to 255; refer to option [3] in section [004])

PGM timer

005

[013]

Door unlock schedule

Start Time

End Time

S   M   T    W   T    F   S    H

Schedule A:

___ ___ : ___ ___

___ ___ : ___ ___

1    2    3    4    5    6    7    8

Schedule B:

___ ___ : ___ ___

___ ___ : ___ ___

1    2    3    4    5    6    7    8

 Event Group

Feature Group

 Start #

End #

Section

Section

Section

Section

PGM Activation

[014]

__/__/__

[015]

__/__/__

[016]

__/__/__

[017]

__/__/__

PGM Deactivation

[018]

__/__/__

[019]

__/__/__

[020]

__/__/__

[021]

__/__/__

SECTION [022]: Safe Mode Options

SECTION [031] PGM Options 2

Option

OFF

ON            

Option

OFF

ON

[1]

Safe Mode

 

N

 Disabled

U

 Enabled

[1]

Flexible PGM Deactivation Option

U

 PGM 

Timer only

N

 Timer / 

Deactivation 
event

[2]

Safe Mode Access

 

N

 Disabled

U

 Enabled

[2]

Reload Timer on Activation Event

U

 Don’t 

Reload 

 

N

 Reload 

Timer

[3]

Reader Safe Mode Feedback

U

 Visual

N

 Visual & 

audible

[3] to [8] Future Use

 

N

 N/A

N

 N/A

[4]

Unlock Door in Safe Mode

U

 Disabled

 

N

 Enabled

[5]

Access Cards in Safe Mode

U

 Safe 

Cards only

 

N

 Any Cards

[6] to [8] Future Use

 

N

 N/A

N

 N/A

Section

Data

Description

Default

[023]

__/__/__  (001 to 024 hours; 000 = Disabled)

Safe Mode Door Unlocked Period

000

[024]

__/__/__  (001 to 255 seconds; 000 = Follow REX)

REX Unlocked Period

000

[025]

__/__/__  (000 to 003)

Red LED Brightness

003

[026]

__/__/__  (000 to 003)

Green LED Brightness

003

[027]

__/__/__  (000 to 003)

Buzzer Frequency

001

[028]

__/__/__  (000 to 255 minutes; 000 = instant)

AC Restore Report Delay

005

[029]

__/__/__  (000 to 255 minutes)

Stay Lock Delay

000

[030]

Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.

[032]

__/__/__  (000 = steady, 001 to 254 = pulsed (increments of 8ms), 255 = pulsed fire)

PGM Output type

000

[040]

Access Card Serial Number Display: View an access card’s serial number displayed on any LCD or Grafica keypad on the combus.
When the DGP-ACM12 is in access card display mode, the door connected to the module cannot be accessed.

[061]

Assign Safe Mode Access Card 1 (Present Card 3 Times)

[062]

Assign Safe Mode Access Card 2 (Present Card 3 Times)

[063]

Assign Safe Mode Access Card 3 (Present Card 3 Times)

[064]

Assign Safe Mode Access Card 4 (Present Card 3 Times)

[070]

Delete All Safe Mode Access Cards

[071]

Delete Safe Mode Access Card 1

[072]

Delete Safe Mode Access Card 2

[073]

Delete Safe Mode Access Card 3

[074]

Delete Safe Mode Access Card 4