12

 

  

Reference & Installation Manual  

 

Part 4: Programming Methods

The 728 Ultra and 738 Ultra control panels can be programmed using either the keypad or the Espload Software (V3.0 or higher for 728 
Ultra, and V3.4 or higher for 738 Ultra). We highly recommend programming the control panels using the Espload Software, as it simplifies 
the process and reduces the potential for data entry errors. 

4.1

Espload Software

With the Espload Software (V3.0 or higher for 728 Ultra, and V3.4 or higher for 738 Ultra), you can program the 728 Ultra and 738 
Ultra control panels remotely via modem or locally using an ADP-1 adapter. The advanced Espload software can execute fast 
uploads or downloads and provides many powerful features. These include a comprehensive monitoring mode to oversee all 
panel activity, a scheduler to initiate pre-programmed tasks at set intervals, and a batch mode to carry out pre-programmed tasks 
following a call from the control panel. Using Espload there is no limit to the number of account files or panel defaults created and 
you can assign thousands of programming combinations to the PGM outputs. Espload can also be converted to the language of 
your choice. Contact your local Paradox Distributor for your free copy of the Espload software.

4.2

Keypad

When programming, use the 

728 Ultra & 738 Ultra System Programming Guide

 to keep track of which addresses were 

programmed and how. Before you begin programming the control panel, we recommend that you read Parts 5 through 11 of this 
manual in order to give you a good understanding of the control panel and its many features. When programming with the 
keypad, certain addresses are programmed using different methods. These methods are described in detail below. Each section 
in this manual will reference the appropriate programming method.

4.2.1

Hex Programming

Addresses 000 to 043 and 300 to 527 are programmed using the Hex Programming method. In this mode, you can 
enter any hex-digit from 0 to F where keys 

[1]

 to 

[9]

 represent digits 1 to 9 respectively; the other keys represent hex-

digits A to F as shown in Figure 23. To program using the Hex Programming method:

1. Press 

[

ENTER

]

 + Installer code. The 

[

ENTER

]

 key will flash indicating you are in programming mode (LED keypad only).

2. Enter the desired 3-digit address. The keypad will display the 2-digit data currently saved at this address as 

described in Figure 23.

3. Enter 2-digit data. After entering data you do not need to press 

ENTER

, the software will automatically save the data 

into the selected address.

4. Return to step 2 to continue programming or press 

[

CLEAR

]

 to exit programming mode.

Figure 23: Hex Programming

Hex Digit Data Display for LED Keypads

Note: LCD keypads will display current data on the screen.

Therefore 2-digit data = 7A

= First digit = 4 + 2 + 1 = 7

= Second digit = 8 + 2 = 10

Note: Values 10 to 15 represent hex digits A to F respectively. See the 
keypads at left.

Each key in the first 2 rows of the keypad represents a specific value when the 
key is lit, as shown above. If the key isn’t lit, the key represents 0. The sum of the 
values of the lit keys in the first row correspond to the second hex digit. The sum 
of the values of the lit keys in the second row correspond to the first hex digit as 
shown in the example below.

Sum of the second row = first hex digit

Sum of the first row = second hex digit

If the key is not lit, value = 0

Содержание 738ULT

Страница 1: ...Versions 4 4 728ULT 4 1 738ULT Reference Installation Manual 728ULT 738ULT...

Страница 2: ......

Страница 3: ...12 Hex Programming 12 Hex Streamlined Section Programming 13 Decimal Programming 13 Feature Select Programming 13 Panel Settings for Espload 14 Panel Answer Options 14 Panel Identifier 14 PC Password...

Страница 4: ...Functions 40 Programming Master and User Codes 40 Regular Arming 40 One Key Regular Arming 40 Force Away Arming 40 Stay Arming 41 One Key Stay Arming 41 One Key Instant Arming 41 Fast Exit 41 Arming...

Страница 5: ...istor output 738 Ultra Serial data output 1200 1 N for use with accessory modules not for use with UL systems Please refer to Warnings on page 45 for UL Specifications Specifications may change withou...

Страница 6: ...lled outlets to power the transformer Use a 16 5Vac 50 60Hz transformer with a minimum 20VA 40VA recommended rating to provide sufficient AC power UL cUL listed systems require a Universal Model No UB...

Страница 7: ...p battery no AC At 8 5 volts the panel shuts down and all outputs close 2 3 5 Keypad Function Test We recommend conducting a power up test on keypads installed far from the control panel To do so temp...

Страница 8: ...row dry contacts that follows the bell siren alarm output If the Bell Siren output is not being used connect a 1k9 resistor across the BELL and BELL terminals Figure 5 Bell Siren Output Connection 2 6...

Страница 9: ...keypad zone input terminal is not being used disable it by shorting the blue zone wire with the black COM wire of the keypad Disabling 642 Keypad Zones If the keypad zone input terminal is not being u...

Страница 10: ...am the keypad definitions as follows Keypad Programming Mode option 2 Keypad Options Key 1 ON Keypad Zone Enabled Keypad Programming Mode option 2 Keypad Options Key 2 ON Requires 1k9 EOL Keypad Progr...

Страница 11: ...er cut and wire fault short recognition all detection devices must use normally closed contacts Connect the devices and program the control panel as shown in Figure 14 This setup will communicate an o...

Страница 12: ...the detection devices and program the control panel as shown in Figure 16 Do not use devices with normally open contacts as this will cause the system to remain in alarm This setup will communicate th...

Страница 13: ...e Figure 18 and display open zones on the keypad Any tampers cuts and or wire fault shorts detected on the system are communicated as per Tamper Wire Fault Recognition Options on page 38 Figure 18 N C...

Страница 14: ...s are pressed at the same time see PGMs Programmable Outputs on page 35 Address 039 BYP 2ND Address 042 2ND 6 Address 040 5 0 Address 056 0 3 0 All smoke detectors must be connected using a daisy chai...

Страница 15: ...en programming user codes an option for either 4 digit or 6 digit access codes can be programmed When the 4 digit option is selected entering a 4 digit code will allow the person access Using the 6 di...

Страница 16: ...its many features When programming with the keypad certain addresses are programmed using different methods These methods are described in detail below Each section in this manual will reference the a...

Страница 17: ...address 044 to 061 The keypad will now display the current 3 digit data currently saved at this address as described in Figure 24 3 Enter 3 digit data decimal value After entering data you do not nee...

Страница 18: ...before the number of pre programmed rings has elapsed the control panel will keep the number of rings in memory for 64 seconds If you hang up and call the installation site back within 64 seconds the...

Страница 19: ...ll communication and erase any unreported events in the buffer until the next reportable event Use the Master or User code 1 to cancel communication attempts with Espload ENTER Installer Master and Us...

Страница 20: ...Features Auto Test Report Addresses 046 to 048 Manual Test Report BYP Key Access Power Failure Report Delay Address 054 Recent Close Delay Address 060 Report Zone Restore Options Address 088 BYP Repor...

Страница 21: ...uence again 6 1 3 Split Reporting When the system is not in alarm the control panel will report all Event codes to Monitoring Station Telephone 2 MSTN2 If communication fails the dialer will hang up w...

Страница 22: ...mum of 16 digits If you would like to enter any special keys or functions refer to Table 5 If the telephone number contains less than 16 digits press the TBL TRBL key to indicate the end of the teleph...

Страница 23: ...ble 6 Communicator Formats 6 5 1 Ademco Contact ID All Codes Please note that this format must use a 4 digit system account code see section 6 4 Ademco Contact ID is a fast communicator format that us...

Страница 24: ...SYSTEM TROUBLE 2 2 110 FIRE ALARM 2ND 2 301 AC LOSS 2 3 111 FIRE SMOKE 2ND 3 302 LOW SYSTEM BATTERY 2 4 112 COMBUSTION 2ND 4 305 SYSTEM RESET 2 5 113 WATER FLOW 2ND 5 306 PROGRAM CHANGED 2 6 114 HEAT...

Страница 25: ...ength of time that the data will be continuously transmitted Enter 2ND or 1 to F to program a value from 8 seconds to 120 seconds Refer to Table 9 for the Pager Delay Values 6 7 Pager Format Transmiss...

Страница 26: ...ra The control panel will send the programmed event code to the monitoring station as soon as the zone closes after having generated an alarm or as soon as the zone closes after bell cut off For more...

Страница 27: ...13 Panic 1 Keys 1 and 3 are pressed to activate a Panic 1 alarm 514 Panic 2 Keys 4 and 6 are pressed to activate a Panic 2 alarm see Keypad Panic Options on page 37 515 Panic 3 Keys 7 and 9 are presse...

Страница 28: ...BYP ENTER 6 13 Power Failure Report Delay Decimal Programming D Address 054 Default 30 minutes After a power failure the control panel will delay transmission of the event code programmed at address 4...

Страница 29: ...ined Keypad Zone 1 2 Supervision Enabled Disabled Address 090 Keys STAY AWAY FORCE Independent Zone Definitions Only one of these options can be assigned to a zone If a zone is assigned more than one...

Страница 30: ...dress 090 Keys STAY AWAY FORCE Independent Zone Definitions Only one of these options can be assigned to a zone If a zone is assigned more than one option the control panel will apply the option with...

Страница 31: ...3 Intellizones 728 Ultra Feature Select Programming D Address 092 Keys 1 to 10 0 738 Ultra Feature Select Programming D Addresses 092 and 094 Keys 1 to 10 0 STAY 11 and FORCE AWAY 12 If an alarm cond...

Страница 32: ...smoke detector recognition disabled Enable this feature to have the control panel recognize 2 wire smoke detectors With this feature enabled input 3 or zone 3 will be reserved for 2 wire smoke detecto...

Страница 33: ...isarmed Zones assigned to System B will arm disarm when the system is System B Armed Disarmed Zones assigned to both systems dual area will arm when the system is either System A Armed System B Armed...

Страница 34: ...R 7 12 EOL Zones Enabled Disabled Feature Select Programming D Address 088 Key MEM Default Enabled No EOL If the system requires the use of 1k9 end of line resistors on zone input terminals disable th...

Страница 35: ...Stay Arming Address 088 key 8 Keyswitch Arming Address 086 keys 2 3 Bell Squawk Address 086 MEM key Exit Delay Address 049 Alarm Transmission Delay Address 059 Bell Cut Off Time Address 052 Beep on E...

Страница 36: ...ng hours 2 digits representing minutes ENTER 8 1 2 Auto Arming Options Feature Select Programming D Address 090 Key 2 Default Regular Arming The Auto Arm feature will arm the system as described in Ta...

Страница 37: ...t Delay Decimal Programming D Address 049 Default 60 seconds The exit delay applies to all zones This option determines how much time the user has to leave the protected area after entering a valid ac...

Страница 38: ...es can arm System B Addresses 074 to 078 Selected keys indicate which user codes can bypass zones 8 13 Closing Delinquency Timer Decimal Programming D Address 061 Default Disabled Feature Select Progr...

Страница 39: ...Setting on page 35 If the PGM is triggered again before the period has elapsed the PGM will remain in its opposite state and reset the timer OR Logic Will trigger a PGM when at least one event occurs...

Страница 40: ...ode This mode will display the 2 digit data for addresses 039 to 043 6 Record these numbers and program them into the control panel or use the Espload Software to download the data directly to the con...

Страница 41: ...use the pulse dialing or tone DTMF dialing format Key 7 OFF Pulse Dialing Key 7 ON Tone DTMF Dialing ENTER Installer code 0 8 6 7 ON OFF ENTER 10 3 Dialing Pulse Rates Feature Select Programming D Ad...

Страница 42: ...rogramming D Address 088 Keys 0 and STAY Default Disabled If the control panel detects an open or a short on a zone when the system is armed regardless of the tamper wire settings it will always gener...

Страница 43: ...see Trouble Display Monitoring on page 43 10 11 Audible Trouble Warning Feature Select Programming D Address 090 Key 9 Default Disabled Trouble conditions will cause the keypad to emit an intermitten...

Страница 44: ...it delay the keypad will beep and the light will flash at a faster rate At the end of the exit delay the keypad will emit a confirmation beep the light will extinguish and the light will remain illumi...

Страница 45: ...ll switch all entry delay zones to instant zones see Instant Zones Entry Delay 1 and Entry Delay 2 on page 29 Therefore any entry delay zone that is breached will immediately generate an alarm instead...

Страница 46: ...t generating an alarm Do not use the 646 LED and 642 LCD keypads for UL installations Both the 646 LED keypad and the 642 LCD keypad are not UL listed 11 8 Keyswitch or Pushbutton Arming Disarming A k...

Страница 47: ...be replaced as it will not provide adequate back up current in case of AC loss If the control panel is currently running on battery power the illumination of the 1 key indicates that the battery volt...

Страница 48: ...key will illuminate to indicate that the control panel has not detected the presence of a telephone line for 30 seconds 11 12 10 Fire Loop Trouble Key STAY The illumination of the STAY key indicates a...

Страница 49: ...erference will not occur in a particular installation If this equipment does cause harmful interference to equipment intermittently the user is encouraged to try to correct the interference by one or...

Страница 50: ...nal Code E Country of Origin CANADA CAN AC Ringer Equivalent Number 01B USOC Jacks RJ31X Equipment Description Control panel for residential burglar and fire warning systems Rechargeable Acid Lead or...

Страница 51: ...33 Bypass Enabled Zones 29 Manual Zone 42 Recall 42 Tamper Options 39 C Call Back 15 Call Espload 15 Cancel Communication 15 Chime Zones Keypad 43 Closing Delinquency Timer 34 Code Priority 34 Commonl...

Страница 52: ...r Options 14 Identifier 14 Settings for Espload 14 Time 38 Panic Codes 23 Keypad Options 37 Silent Option 34 Parallel Wiring ATZ 9 Partition Arming Disarming 41 Partitioning 29 PC Password 14 PGM Opti...

Страница 53: ...one Line Monitoring TLM 37 Telephone Line Monitoring Table 37 Telephone Number Special Instructions Table 18 22 Test Battery 3 Keypad Function 3 Test Report Auto 23 Manual 24 Test Transmission Timed 2...

Страница 54: ...Notes...

Страница 55: ......

Страница 56: ...8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox ca 780 Industr...

Отзывы: