background image

Spectra LED Keypads 5

1.0 INTRODUCTION

Thank you for selecting the 

Spectra Security System

 from

Paradox Security Systems

. The Spectra Security System

will give you peace of mind by providing reliable security
protection. Although, it can do much more than that. The
Spectra System can realize your dreams of home automation
such as controlling garage doors, lights, heating, temperature
and much more. Consult your installer to take full advantage
of your Spectra system’s capabilities. 

This advanced technology security system provides you with
reliable security protection and powerful features that anyone
can use without memorizing complex and confusing codes.
The system consists of the Spectra Control Panel, one or
more Spectra Keypads, various input devices (i.e. motion
detectors, door contacts, etc.) and various output devices (i.e.
bells, sirens, lights, etc.). 

The elegant and user-friendly 

Spectra 1686H and 1686V LED

Keypads

 allow you to easily access your security system's

functions and provide you with an easy-to-understand display
of your security system's alarm and operational status. All the
actions performed in your security system will be executed and
displayed through the keypad. Therefore, before using your
security system, we highly recommend you read this manual
carefully and have your installer explain basic system
operation to you.
     

1686EU04.fm  Page 5  Tuesday, August 13, 2002  10:01 AM

Содержание 1686H

Страница 1: ...10 Zone Spectra LED Keypads User s Guide...

Страница 2: ......

Страница 3: ...lay 9 Partitioning 13 Programming Access Codes 14 System Master Code Default 123456 14 Master Codes 14 Duress Code 15 Programming Access Codes 15 Arming Disarming 17 Exit Delay 17 Disarming Deactivati...

Страница 4: ...ramming Chime Zones 26 Keypad Muting 26 Panic Alarms 27 Program Time clock 27 PGM Button Programmable Outputs 28 Quick Function Keys 28 Keypad Backlight 29 Fire Alarms 30 Testing Maintenance 33 System...

Страница 5: ...d powerful features that anyone can use without memorizing complex and confusing codes The system consists of the Spectra Control Panel one or more Spectra Keypads various input devices i e motion det...

Страница 6: ...ystem Checklist in section 8 0 for details 2 1 AUDITORY FEEDBACK When you enter information on the keypad it will guide you with beep tones that communicate acceptance or rejection of your entries You...

Страница 7: ...Spectra LED Keypads 7 Figure 2 1 Overview of the 1686V LED Keypad...

Страница 8: ...f a button s light is off extinguished the corresponding zone is closed If a button s light is on illuminated the corresponding zone is open i e open door movement detected etc 2 4 ALARM MEMORY DISPLA...

Страница 9: ...ble condition has occurred Press the TRBL button to stop the Trouble Beep We strongly suggest that you inform your Security Company of the trouble and allow them to service your system How Do I Access...

Страница 10: ...trouble appears contact your Security Company for service 2 5 4 Bell PGM2 Disconnected Trouble 4 When the 4 button illuminates the bell siren or any device connected to the PGM2 is no longer connecte...

Страница 11: ...en the 9 button illuminates a wiring problem is occurring on one or more zones 2 5 10 Telephone Line Monitoring Failure 10 When the 10 button illuminates the system has not detected the presence of a...

Страница 12: ...5 14 Keypad Fault FORCE If for any reason your keypad is no longer communicating with your alarm system the keypad will emit four consecutive beeps at 3 second intervals Press any button on the keypa...

Страница 13: ...2 Partitioning can be used in installations where shared security systems are more practical such as a home office or warehouse building When partitioned each zone each User Code and many of your sys...

Страница 14: ...ess Code can arm or disarm the system refer to the System Checklist in section 8 0 3 1 SYSTEM MASTER CODE Default 123456 The System Master Code can arm or disarm any partition using any of the methods...

Страница 15: ...ced to arm or disarm your system entering the Access Code assigned to User 048 will arm or disarm the system and immediately transmit a silent alert Duress Code to the Security Company The Duress Code...

Страница 16: ...or 6 digit ACCESS CODE ENTER button flashes Return to step 3 to enter next code or press CLEAR to exit How Do I Delete Access Codes 1 Repeat steps 1 to 3 see above 2 Press the FORCE button once for e...

Страница 17: ...Delay and the keypad may beep During the final 10 seconds the beeping and the light will accelerate 4 2 DISARMING DEACTIVATING AN ALARM To disarm an armed system or an alarm enter your access code An...

Страница 18: ...MATION BEEP the ARM Light will turn off IF YOU HAVE ACCESS TO BOTH PARTITIONS see section 2 6 3 Buttons 1 and 2 will flash Press the button corresponding to the desired partition For both partitions p...

Страница 19: ...are bypassed when Stay Arming For example when you go to sleep at night doors and windows can be armed without arming other zones like motion detectors When you correctly Stay Arm the system the ARM L...

Страница 20: ...orce Arming allows you to rapidly arm the system without waiting for all zones in the system to close During Force Arming a Force Zone is considered deactivated until it closes then the system will ar...

Страница 21: ...mming allows you to program the alarm system to ignore deactivate specified zones the next time the system is armed For example you may wish to bypass certain zones when workers are renovating part of...

Страница 22: ...do I Program Bypass Entries 1 Press the BYP button 2 Enter your ACCESS CODE see Note1 3 Illuminate the button s corresponding to the zone s you wish to bypass by pressing the corresponding button Pres...

Страница 23: ...m all zones not defined as Stay Zones For details on Stay Arming refer to section 4 4 4 7 3 Fast Exit WHEN THE SYSTEM IS ALREADY STAY ARMED this feature will allow you to exit already armed premises a...

Страница 24: ...BYP button for 3 seconds see Note2 to access Bypass Programming Mode see section 4 6 4 8 KEYSWITCH ARMING A keyswitch can be used to arm and disarm the system A keyswitch is assigned to and programmed...

Страница 25: ...automatically arm A 60 second Exit Delay see section 4 1 will start before the system arms At this point Auto Arming can be cancelled by entering your access code 4 9 2 No Movement Auto Arming Your p...

Страница 26: ...5 1 PROGRAMMING CHIME ZONES This feature allows you to program which zones will be Chime Enabled A Chime Enabled zone will advise you every time it is opened by causing your keypad to emit a rapid int...

Страница 27: ...n send a message to your Security Company The three different panic alarms can communicate specific messages to your monitoring station For instance pressing 1 3 can mean call the police or anything y...

Страница 28: ...econds 5 6 QUICK FUNCTION KEYS Upon request of your installer or Security Company you may have to perform one of the following Press 5 6 1 TEST REPORT ENTER MASTER CODE MEM If your system is monitored...

Страница 29: ...levels The MEM key is used to set the desired level Each consecutive push of the MEM key will increase the backlight level until the maximum level is reached After reaching the maximum level the backl...

Страница 30: ...t unnecessary reporting of false alarms If there is no fire condition contact your Security Company immediately to avoid an unnecessary response What do I do if a Delayed Fire Zone was set off acciden...

Страница 31: ...Spectra LED Keypads 31 Figure 6 1 Delayed Fire Zone Flowchart...

Страница 32: ...n in apartments since the heating systems in single family homes are often not professionally maintained Fire Safety Tips In the event of a fire remember time is the biggest enemy and every second cou...

Страница 33: ...and the READY Light on activate motion detectors by walking in the protected area Open and close protected doors and verify that the corresponding button illuminates Your installer can advise you of...

Страница 34: ...24Hr Entry Delay 01 ______________ ____ N N N N N 02 _____________ Keyswitch Y N N N Type ____________ ____ N N N N N 03 ______________ Fire Zone Y N N N Delayed Y N N N ____ N N N N N 04 ____________...

Страница 35: ...N N 16 ______________ ____ N N N N N User and Name Partition 1 or 2 Byp Stay Force Arm Only PGM Only 001 ___________ System Master Code Default 123456 1 2 N N 002 ___________ Master Code 1 ____ N N N...

Страница 36: ...17 ___________ ____ N N N N N 018 ___________ ____ N N N N N 019 ___________ ____ N N N N N 020 ___________ ____ N N N N N 021 ___________ ____ N N N N N 022 ___________ ____ N N N N N 023 ___________...

Страница 37: ...__________ ____ N N N N N 038 ___________ ____ N N N N N 039 ___________ ____ N N N N N 040 ___________ ____ N N N N N 041 ___________ ____ N N N N N 042 ___________ ____ N N N N N 043 ___________ ___...

Страница 38: ...ent N Audible N Off PGMs PGM 1 ___________________________________________ PGM 2 ___________________________________________ PGM 3 ___________________________________________ System Timers Enter and e...

Страница 39: ...by __________________ Tel ______________ Monitored by _________________ Tel _______________ Your account number ____________________________ Alarm transformer location ________________________ on cir...

Страница 40: ...entering the required data After entering a digit the number corresponding to the following programmed digit will illuminate and so forth For example if you wish to change User Code 004 from 123456 to...

Страница 41: ...______________ _______________________________________ _______________________________________ _______________________________________ _______________________________________ _________________________...

Страница 42: ...onjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing...

Страница 43: ......

Страница 44: ...780 boul Industriel St Eustache Montr al Qu bec J7R 5V3 Fax 450 491 2313 www paradox ca PRINTED IN CANADA 08 2002 1686EU 04...

Отзывы: