Spectra LED Keypads 21
the motion detector is a
Force Zone
, the system will allow
you to arm even if the zone is open.
When you correctly
Force Arm
the system, the “
ARM
” Light
corresponding to the armed partition will turn on and the
Exit Delay
will initiate (see section 4.1).
Force Arming
can
also be activated by using
One-Touch Force Arming
(see
section 4.7.4).
4.6 M
ANUAL
B
YPASS
P
ROGRAMMING
Manual Bypass Programming
allows you to program the
alarm system to ignore (deactivate) specified zones the next
time the system is armed. For example, you may wish to
bypass certain zones when workers are renovating part of
your establishment. Please note that a
Fire Zone
cannot be
bypassed.
How Do I Force Arm?
1) Close zones in the desired partition (except
Force
Zones
).
2) Press the
[
FORCE
]
button
3) Enter your
[
ACCESS
CODE
]
IF
YOU
HAVE
ACCESS
TO
BOTH
PARTITIONS
(see section 2.6):
4) Buttons
[1]
and
[2]
will flash. Press the button
corresponding to the desired partition
.
For both partitions,
press the other button after the “C
ONFIRMATION
B
EEP
”.
1686EU04.fm Page 21 Tuesday, August 13, 2002 10:01 AM