Paradox Hellas S.A. Elix Скачать руководство пользователя страница 2

The system will automatically exit the programming mode if no user interaction takes place for more than 60 

seconds.
The programming procedure consists of two (2) steps. The user advances to the next step by pressing the 

PRG/TEST

 button for more than 3 seconds. The steps are described below:

STEP 1: Brightness level with main power present (

PWR

 and  

FLT

 LEDs blinking)

In this step the user sets the brightness level produced by ELIX while the mains supply power is present. By 

instantaneously pressing the 

PRG/TEST

 button the brightness cycles through the  six (6) available levels 

(including the off state). When the desired brightness is active, the user presses the 

PRG/TEST

 button for 

more than three (3) seconds; the brightness level is saved and the programming continuous to STEP 2.

If EMERGENCY ONLY operation is required the user must select Zero Brightness (Lighting 

element OFF).

STEP 2: Brightness level during mains power loss (

PWR

 and  

BAT

 LEDs blinking)

In this step the user sets the brightness level produced by ELIX while the mains supply power is lost. By 

instantaneously pressing the  

PRG/TEST

 button the brightness cycles through the  five (5) available levels 

(minimum to maximum brightness). When the desired brightness is active, the user presses the  

PRG/TEST

 

button for more than three (3) seconds; the brightness level is saved and the programming is completed.
After the completion of the programming steps ELIX returns to normal operation.

During the programming operation, ELIX does not check the mains power or execute any 

diagnostic tests. 

3. Indications Functionality

PWR Indication (green LED)

•  OFF:

 Mains voltage is low or lost.

•  ON:

 Mains voltage is present.

FLT Indication (yellow LED)

•  OFF: 

Light Elements in normal mode.

•  Blinking:

 Light Elements Fault.

BAT Indication (red LED)

•  OFF: 

Battery is working properly.

•  ON: 

Battery Fault.

•  Blinking: 

Battery has lost capacity and will need to be replaced soon.

SYSTEM IN NORMAL OPERATION MODE

LED INDICATOR

STATE

Description

PWR 

(green)

ON

Mains power present

OFF

Mains power is lost

FLT 

(yellow)

BLINK

Light element Fault

BAT 

(red)

ON

Battery Fault

BLINK

Battery reduced capacity, needs to be replaced soon

SYSTEM IN PROGRAMMING MODE

LED INDICATOR

STATE

Description

PWR

BLINK

System enters programming mode

FLT

BLINK

System is in STEP 1

BAT

BLINK

System is in STEP 2

Содержание Elix

Страница 1: ... 1 ELIX LED indications If the PRG TEST button is pressed for an interval Less than 3 seconds the system s diagnostic test starts Between 3 and 30 seconds the system s programming operation starts More than 30 seconds the system restores the default settings 2 1 Test Procedure 1 Battery Internal Resistance Test The battery presence is checked The battery internal resistance is checked The battery ...

Страница 2: ... is lost By instantaneously pressing the PRG TEST button the brightness cycles through the five 5 available levels minimum to maximum brightness When the desired brightness is active the user presses the PRG TEST button for more than three 3 seconds the brightness level is saved and the programming is completed After the completion of the programming steps ELIX returns to normal operation During t...

Страница 3: ...ently holding it from it s bottom side and pulling outward 4 Use the back cover to mark the required drill points on the mounting surface wall Drill the required holes 5 Remove one of the three available knock outs pass the mains cable through 6 Place the back cover on the wall and fix it in place with screws 7 Connect the mains cable on the terminal block 8 Place the reflector assembly by sliding...

Страница 4: ... mm2 12 18 AWG If multi stranded wire is used for the mains connection the ends of the wire should never be tinned If desired wire ferrules may be fitted Controlgear is suitable only for ELIX LDM Lighting Element Failure The lighting elements of the ELIX unit are NOT user replaceable In case of failure the unit must be either replaced or serviced by qualified personnel This failure is indicated by...

Отзывы: