18
THE PROCEDURE:
IMPORTANT! During the measurement process, the mic must point toward the ceiling,
positioned at ear level when you are seated.
1. Position microphone on or near the first position (see diagram on page 16). Remove
cushions from seating, if necessary, to attain correct height. To adjust the height of
the telescoping stand, loosen the large black clamp in the middle of the stand by
rotating it counter-clockwise; retighten once desired height has been achieved. Five
listening positions are normally measured but this number can be increased to ten
positions (see diagram on page 16) —the first position must be at or just in front of
the central seating position. Positions 2 and 3 should be symmetric to the left and
right of the center line. The same applies to the remaining positions.
IMPORTANT: Even if your room has less than five seating positions, to ensure optimal
sound, measurements must be taken from five different listening positions. Each
position should be at least 2 feet (60 cm) apart.
2. Set the microphone in the first position;
3. Run ARC Genesis on your computer. The program will guide you through the steps
and at the conclusion, will give you the option to load the correction data into your
subwoofer. The entire measurement process takes about 5 minutes.
4. Once the ARC Genesis program is finished, you can disconnect the computer
from the microphone and subwoofer.
5. If the position of your subwoofer or listening positions change, you should run the
ARC Genesis calibration process again to ensure accurate performance after your
room changes have been made.