Post-Installation Checks and Testing
Post-Installation Checks
40
ACS-1E and ACS-1EUL Install and Service Manual
Ver 2
4.1.1 Preliminary Tools and Materials
• 1x Small flat-blade screw driver (for wire terminal blocks)
• 1x Medium Phillips screw driver (for circuit board mounting screws)
• 1x Digital Multimeter {DMM} (with Low Resistance range or “Continuity” function)
4.1.2 Preliminary Hardware Checks
1. Check to see that all ACS-1E or ACS-1EUL circuit board mounting screws are tight
2. Check all Input and Output wires (especially those sheathed extensions carrying Card Reader sig-
nals, sensor signals, and door-lock control current) to make sure they are wired as directed
3. Check all circuit board connections to make sure they are physically tight
4. Check all wire-to-wire connections to make sure they are tight (and if outdoors, weather resistant)
and that there is no exposed copper.
5. For Card Readers: Make sure the white wires from the Card Readers are properly connected to the
white wires of the Tamper-Detect switch in the mounting collar or box. Make sure the Card Reader
is properly seated in its mounting collar or box and the Tamper-detect switch “finger” is depressed.
Door Sense Jumper (JP1)
Near coin-cell battery and Maintenance
Mode push-button. Sets the Door Sense
to normally-closed (NC) when in place.
Jumper in place on Door Sense terminal
block and on JP1.
Egress (Exit) Switch Input
Input opens door (activate door relay) for
selected amount of time.
Normally-Closed (NC); with jumper
across the terminal block when Exit
switch is not required.
Egress Activation Time
Delay time for an active door-control relay
after an Egress switch is activated.
5 seconds
Door Override Input
Activates door-control relay(s).
Normally-Closed (NC); with jumper
across the terminal block when Door
Override output signal is absent.
Holiday Schedule
Standard holiday schedule file for current
years (or next year).
Standard Holiday Schedule in place
Port Number Value
Internet port number value
Port 2000
Sensor Configuration
Mapping
Allows configuration of Outputs 1 & 2 (and
I/O Relay Outputs), assignment of Card
Reader alerts, I/O Inputs, and Inhibit functions.
All assignments are blank
Suspect Card BIN File
System expects: 9999999999999999 string in
Stolen Card Binfile or Controller will lock up
after first card-read.
9999999999999999 in Stolen Card Binfile
Suspect Card Function
Controller scans up to 50 stolen or
“suspected” cards from a small Binfile, locks
down the Card Reader(s) and door control
relay(s) when a suspected value is detected.
Not selected/activated
TABLE 4–1. Controller Default Settings
Function
Description
Default Settings