WALLMOUNT CONFIGURATION

The wallmount configuration

 

allows the user to mount the UPS on the wall.  There is

a wallmount bracket kit available for the UPS.  The kit includes two wall mounting
brackets, ten retaining screws, and the wallmount template.  

WARNING: 

Use two or

more people when installing the UPS.   Use 

CAUTION,

 the UPS is extremely heavy.

The UPS's side panels have mounting bracket screw holes for attaching the wall
mounting brackets.
1.  Once the location and position of the UPS has been determined, lay the UPS do-
      wn flat.

WARNING:  

The UPS must be installed in the proper up-right position.  If the UPS is

not installed in the proper up-right position the Batteries will be damaged.  Once the
UPS is placed on the wall, looking at the front panel the YELLOW Battery discon-
nected label on the top cover of the UPS MUST be on your left hand side.
2.  Align the mounting brackets with the mounting bracket screw holes and attach w-
    ith the six retaining screws.
3.  Use the template to mark the screw hole position on the wall.  

CAUTION, 

you sh-

     ould always were protective gear for your hands and eyes when operating power
     tools.
4.  Attach the four retaining screws to the wall and make sure that all of the retaining
    screws are screwed into structural material.  Then clean the area of any loose m-
     aterial.  Do not tighten the retaining screws all the way, leave approximately 3/8" of
     the retaining screws sticking out.
5.  Position the UPS, so that the mounting bracket keyed holes line up with the four
     retaining screws.  Slide the UPS down until its resting securely on the four retai-
     ning screws.
6.  Tighten the four retaining screws to secure the UPS to the wall.
7.  The LCD panel can be rotated to read in the up-right position.  Remove the front
      panel from the UPS.  On the backside of the front panel, push the LCD panel out-
     wards, the panel will pop out.  Position the LCD panel so that it reads in the up-
     right position.  Re-install the front panel on the UPS.
8.  The Wallmount Configuration is complete.  See Connecting your Equipment.

TOWER CONFIGURATION

The tower configuration allows the user to install the UPS in the up-right position
next to a tower computer.  The tower brackets are provided with the UPS.  

WARNING:

Use two or more people when installing the UPS.  Use 

CAUTION,

 the UPS is ex-

tremely heavy.
1.  Once the location of the UPS has been determined, place the tower brackets in
     the desired location.

WARNING:  

The UPS must be installed in the proper up-right position.  If the UPS is

not installed in the proper up-right position the Batteries will be damaged.  Once the
UPS is placed in the tower brackets, looking at the front panel the YELLOW Battery
disconnected label on the top cover of the UPS MUST be on your left hand side.
2.  Slide the UPS into the tower brackets.  Make sure that the UPS is stable.
3.  The LCD panel can be rotated to read in the up-right position.  Remove the front
      panel from the UPS.  On the backside of the front panel, push the LCD panel out-
     wards, the panel will pop out.  Position the LCD panel so that it reads in the up-
     right position.  Re-install the front panel on the UPS.
4.  The Tower Configuration is complete.  See Connecting your Equipment.

DESKTOP CONFIGURATION

The desktop configuration allows the user to install the monitor, the computer and
the UPS in one single stack.  

WARNING: 

Use two or more people when installing the

UPS.  Use 

CAUTION,

 the UPS is extremely heavy.

1.  Once the location of the UPS has been determined, lay the UPS down flat on the
     desk.
2.  Stack the computer and then the monitor on top of  the UPS.  

NOTE:

 Do not stack

     the UPS on top of the computer.  The UPS is heavy and may damage the other
     equipment.
3.  The Desktop Configuration is complete.  See Connecting your Equipment.

Содержание E750RT2U

Страница 1: ...er s Manual Enterprise Plus LCD RT UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000434...

Страница 2: ...s and Indicators 6 3 Installation 9 4 Operation 15 5 Troubleshooting 19 6 Replacing the Battery 20 7 Obtaining Service 23 8 Specifications 24 9 Configurable Parameters Settings 26 10 Limited Product W...

Страница 3: ...ease read this manual before installing your Enterprise Plus Series UPS models E750RT2U E1000RT2U E1500RT2U E2000RT2U E3000RT2U as it provides important information that should be followed during inst...

Страница 4: ...part ment of Communications These limits are designed to provide reasonable protection against such interference in a residential installation This equip ment generates and uses radio frequency and if...

Страница 5: ...Load Level Bar Graph will be illuminated and the UPS will sound a constant alarm to indicate that there is an Overload condi tion The Battery Capacity Bar Graph operates as follows LED 1 When the bat...

Страница 6: ...wired into two segments to support the Load Shedding Function Labeled Load 1 Load 2 The locking and Always On receptacles La beled Load 3 do not support the Load Shedding Function NOTE The locking re...

Страница 7: ...andard 19 46 5cm rack installed on the UPS The mounting brackets to fit a 23 59 2cm rack and Rail Kits for 4 post racks and cabinets are also available The screws for mounting the UPS to the rack are...

Страница 8: ...e UPS On the backside of the front panel push the LCD panel out wards the panel will pop out Position the LCD panel so that it reads in the up right position Re install the front panel on the UPS 8 Th...

Страница 9: ...rly without this connection For USB port see Note on page 17 CONNECTING THE UPS TO AN AC SOURCE Plug the UPS into a two pole three wire groundedAC wall outlet TheAC wall outlet shall be near the UPS a...

Страница 10: ...tery s capability to provide an acceptable amount of runtime If the UPS fails a self test one of the icons will remain illuminated indicating the type of problem NOTE The UPS will automatically perfor...

Страница 11: ...ps after UPS restarts reduce the load on the UPS UPS operates in battery mode only even though there isAC present The AC normal icon is illumi nated but there is no output Disconnect the computer cabl...

Страница 12: ...frequent short duration discharges have a negative impact on battery life NOTE If there is a power interruption while replacing the hot swappable batteries with the UPS on the load will not be backed...

Страница 13: ...and address B Where and when the unit was purchased C All of the model information about your UPS D Any information on the failure including LEDs that may be illuminated E Adescription of the protect...

Страница 14: ...ull load discharge BM0031 Battery Type Sealed Non Spillable Maintenance Free Value Regulated LeadAcid System Voltage Runtime Full Load minutes Runtime Half Load minutes 13 11 17 5 4 8 SURGE PROTECTION...

Страница 15: ...oducts that are depot repaired or replaced pursuant to this warranty shall be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the ori...

Страница 16: ...tible Power Supplies UPS Model No E750RT2U Y E1000RT2U Y E1500RT2U Y E2000RT2U Y E3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texa...

Отзывы: