background image

1. 

3. 

2. 

4. 

5. 

To calculate the length of the Outlet Pipe 
(12), fi t the pre-assembles bottletrap to the 
basin and meassure from the bottletrap 
shoulder (A) to elbow coupling (B). Add 
25mm for internal pipe connection. (Fig A).

Once the Bottletrap is removed from the 
basin and seals lubricated, slide the Outlet 
Pipe (12) into the Bottletrap shoulder and 
tighten with the Outlet Retaining Nut (11). 
(Fig C)

Cut the the Outlet Pipe (12) to the calculated 
length removing all swarf material from the 
end of the pipe. (Fig B)

Slide the Cover Plate (13) and Kee Rubber 
Seal onto the Outlet Pipe (12). (Fig D)

Lubricate the Kee seal and push-fi t the 
Bottletrap and Outlet Pipe assembly into the 
elbow coupling. (Fig E)
Fit the Bottletrap to the basin waste ensuring 
the height is adjusted to allow fall of water.
Test to ensure the fi ttings are secure and the 
Bottletrap is water tight. 

IMPORTANT:  

Please Ensure there is a minimum 1.5 degree fall in the Outlet Pipe 

when installed to allow waste water to fl ow smoothly.

Fig B

Fig D

Fig C

Fig E

Fig A

A

B

Please measur

this distance

To Basin Waste 

32mm

To Basin

Отзывы: