Working with the SOL.Connect Center
7.8.2.4
Display (optional)
A display may be connected directly or remote to the data logger (remotely
controlled display requires installation of a serial Ethernet converter).
The following data string is sent to the display using type HvG:
Value
Description
#
Starting signal
00
241479
Total yield =
00
241479 kWh
00
1234
Daily yield =
00
1234 kWh
00
1234
Performance (Pac) =
00
12,34 kW
0000
Iac (is not displayed)
0000
Upv (is not displayed)
0000
Uac (is not displayed)
4567
Daily yield 2 = 4567 Wh (usually not used)
<CR><LF>
End signal (optional)
Result:
#002414790012340012340000000000004567
Characters printed in
“red”
are added as enhanced HVG-protocol to support
plant performances > 100 kW. However the display must be designed ade-
quately which requires coordination with the display’s manufacturer.