Page 4
3. In the “OFF” position, the indicator LED will blinking “GREEN” or “RED”
when the test leads are connected to the target pair.
4. Re-confirm by switch to “CONT”, that will terminate the call on the
target line.
TESTING CONTINUITY
(
SWITCH TO “CONT”
)
1. Connect the test leads to the pair (a test lead on a wire).
2. Shorting both wires at the other end of line
3. A bright “GREEN” LED indicates continuity of line is good. LED will not
work if the line resistance exceeds 10K Ohms
TESTING CONTINUITY USING TONE
(
SWITCH TO “TONE”
)
1. Connect the test leads to the pair(a test lead on a wire).
2. Using a Telephone Test Set in monitor mode at the other end of line
3. Reception of clear tone is indicates continuity of line is good.
MODULAR TESTING
All above tests are available through the modular plug in stead of test leads
COAX TESTING
1. Connect red test lead to outer shield and black test lead to center
conductor
2. Or connect red test lead to outer shield and black test lead to ground
MAINTENANCE
The Tone Generator and amplifier probe is maintenance free except for
battery replacement. Below is the Instruction for Battery replacement
Probe Amplifier
Remove the screw from the battery compartment, replace
with new 9V battery and re-assemble screw DO NOT OVERTIGHTEN.
Tone Generator
Separate the case by remove the screw, replace with new
9V battery and re-assemble screw DO NOT OVERTIGHTEN.
Warranty
Warranty limited solely to repairing or replacement, Warranty will not cover
for unit that was defected by accidental, improper uses and one repaired by
other than manufacturer’s personnel.