Contact Grill Collection Operating Manual
–
CGS1S, CGS1R, CGS2S, CGS2R, CGL1S, CGL1R, CGL1S/R, CGL2S, CGL2R, CCG1S, CCG1R, CCG2S, CCG2R, CPG
Tel: 0800 0461570
Fax: 0800 0461571
Web: www.pantheonce.co.uk
Email: [email protected]
Pantheon Catering Equipment
Vulcan Works, Dixon Street,
Bolton, BL6 7PH
Ceramic Contact Grills
The Contact Grill may be “Quick Cleaned” with the scraper provided. The residue may be
emptied into the drip tray under the grill through the opening at the front of the Contact
Grill.
Be sure to clean the drip tray regularly to avoid spills.
For hard to clean spots use the scraper or the metal scrub pad.
There are many non-abrasive cleaners specifically made for ceramic cooking tops on the
market today. We suggest using your choice of non-abrasive cleaner at the end of each day
or service period to keep your Contact Grill in top condition.
Troubleshooting
Problem
Possible Causes
Solution
Module Plates don't heat up when
the power and heating indicators
are both on
The temperature
controller is broken
Replace the temperature
Controller
The heating element
has blown
Replace the heating element.
The high temperature
cut-out has activated
Press the reset button, located on
the underside at the rear of the
unit
Temperature of the grill can’t be
controlled
The temperature
controller is broken
Replace the temperature
controller
The Power Indicator doesn’t
illuminate and the unit won’t heat
up
Check the unit is
plugged in securely
If the grill is not plugged in
securely plug it in securely
The Fuse may have
blown
If the Fuse has blown replace it
The unit will not power on and no
indicators illuminate
Power supply is
abnormal, or the fuse
has broken
Check the power supply or replace
the fuse.
Please Note: If none of these rectify the problem, please cease use of the product and contact the
manufacturer
5