6.2.5 Side Tone Not transmitted (Mic)
Repeat 6-2-1 No receiving tone heard.( Ear-piece )
1. Check to see if C250, R228 voltage is around 2.5V : CP124
2. Check to see if Mic + pin(S216, C257) is around 1.5V : CP125
NO Check that S216, C257, C250 and R228 are cold solder, broken, short to the other
PCB pattern or not
If you find out any defective part, you replace it.
Set to HP8960 to connect a call and tell to mic.
2. Check U201.P16 or C228 pin for wave form : CP126
NO Check that U201 is cold solder, broken, short to the other PCB pattern or not
or Replace MIC
If you find out any defective part, you replace it.
CP124
CP124
CP125
CP125
CP126