background image

2

© 2007

Wohler Technologies, Inc.

   ALL rights reserved

Introduction

Congratulations on your selection of a PANORAMAdtv product. We are confident it represents the best performance and value
available, and we guarantee your satisfaction with it.

If you have questions or comments you may contact us at:

Wohler Technologies, Inc.

31055 Huntwood Avenue

Hayward, CA  94544

Phone:

(510) 870-0810

     Fax: 

(510)  870-0811

US Toll-Free: 

1-888-596-4537

www.panoramadtv.com

[email protected]

1)

Read these instructions.

2)

Keep these instructions.

3)

Heed all warnings.

4)

Follow all instructions.

5)    Do not use this apparatus near water.

6)    Clean only with dry cloth.

7)    Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.

8)       Do not install near any heat source such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9)      Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two blades

with one wider than the other.  A grounding type plug has two blades and a third grounding prong.  The
wide blade or the third prong are provided for your safety.  If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.

10)   Protect the power cord from being walked on or pinched, particularly at plugs convenience receptacles

and the point where they exit from the apparatus.

11)   Only use attachments/accessories specified by the manufacturer.

12)  Use only with the cart stand, tripod, bracket, or table specified by the manufacturer, or sold with the

apparatus.  When a cart is used, use caution when moving the cart/apparatus combination to avoid injury
from tip-over.

13)   Unplug this apparatus during lightning storms or when unused for long periods of time.

14)  Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been

damaged in any way, such as when power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.

15)  Do not expose this apparatus to rain or moisture.

16)  The apparatus shall be connected to a mains socket outlet with a protective earthing connection.

Important Safety Instructions

CAUTION!

In products featuring an audio amplifier and speakers, the surface at the side of the
unit, where the audio amplifier heat sink is internally attached, may get very hot after
extended operation.  When operating the unit excercise caution when touching this
surface and ensure that external materials which may be adversely affected by heat
are not in contact with it. There is a Hot Surface label (see diagram) attached to the
aforementioned surface of the product.

Содержание MON2-3/6.8

Страница 1: ...Applications Specifications and Options Section2 Operation Installation Front Panel Features Rear Panel Features Section 3 Technical Information Tally Control SDI MSDI 4 Input Option CVBS MAV 1 Input Option 1 2 3 4 5 7 9 10 12 17 18 20 21 CONTENTS 1 MON2 3W MON2 3 6 8 3U Dual LCD Video Monitors Document P N 821525 Rev E User Manual ...

Страница 2: ...eing walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip ...

Страница 3: ...ALL rights reserved 3 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Sect 1 General Features and Specifications General Features and Specifications Description Features Applications Specifications Options Section 1 ...

Страница 4: ...n ordering a MON2 3 unit These optional field installable additional composite video inputs with passive loop through are selected with an A B switch on the front panel SMPTE 259M EBU601 serial digital inputs SDI are displayed with installation of the MSDI 4 SDI option Each optional SDI module provides an SDI video input channel with a reclocked SDI video output and a converted composite video out...

Страница 5: ...nty and a satisfaction guaranteed return policy Units are certified to meet at time of manufacture all currently applicable product safety and EMC requirements such as those of CE Features and specifications subject to improvement without notice Specifications Section 1 General Features and Specifications Options Additional input SDI Modules MSDI 4 one per channel Additional input Composite Analog...

Страница 6: ... 2007 PANORAMAdtv ALL rights reserved 6 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E This page left intentionally blank ...

Страница 7: ... 2007 PANORAMAdtv ALL rights reserved 7 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Operation Installation Front Panel Features Rear Panel Features Section 2 ...

Страница 8: ... 2007 PANORAMAdtv ALL rights reserved 8 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 2 Operation Installation Figure 2 a MON2 3 6 8 and MON2 3W Chassis Dimensions ...

Страница 9: ...tain the best operator s viewing angle mount these units as nearly straight on to the operator s position as possible 0 degrees left right or up down Good image quality is assured if viewing angles are between 45 degrees from the center axis in the horizontal plane left right In the vertical axis good image quality is obtained between 10 degrees looking down and 30 degrees looking up The displays ...

Страница 10: ...djust for desired screen brightness CNT Contrast Adjust for desired image scene dark to bright contrast 4 PAL NTSC Indication Yellow LED This indicator shows the detected signal type connected to the CVBS input connector This LED glows yellow to indicate a PAL encoded signal is connected This LED remains dark to indicate an NTSC signal is connected 5 Input I P Selection 2 Position Toggle Switch Th...

Страница 11: ... 2007 PANORAMAdtv ALL rights reserved 11 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 2 Operation Figure 2 b MON2 3 6 8 and MON2 3W Front Panel Features ...

Страница 12: ...nables input video selections from the Remote Source Select Control connector if installed C Loop CVBS BNC Female Connector Signal through connections to down stream equipment are supplied here If you supply down stream equipment from this connector ensure you set the TERM LIFT toggle switch Item D to the LIFT DOWN position If no other equipment is connected via this connector set the TERM LIFT sw...

Страница 13: ... 2007 PANORAMAdtv ALL rights reserved 13 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 2 Operation Figure 2 c MON2 3 6 8 and MON2 3W Rear Panel Features ...

Страница 14: ... switch controls a color bar generator associated with each monitor To view the input signal place this switch in the DOWN position To activate the color bar generator place this switch to the CBAR ON UP position MSDI 4 SDI option is required J Tally Control DB 25 Female Connector This 25 pin sub miniature female D connector allows you to tally individual monitor front panel Tally indicators Full ...

Страница 15: ... 2007 PANORAMAdtv ALL rights reserved 15 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 2 Operation Figure 2 c MON2 3 6 8 and MON2 3W Rear Panel Features ...

Страница 16: ... 2007 PANORAMAdtv ALL rights reserved 16 MON2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 2 Operation This page left intentionally blank ...

Страница 17: ...Module Option FieldUpgrading NOTE PCB layout and schematic support documentation is available upon request PANORAMAdtv 31055 HuntwoodAvenue Hayward CA 94544 1 888 596 4537 Fax 510 870 0811 web www panoramadtv com e mail sales panoramadtv com Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510 870 0810 Fax 510 870 0811 US Toll Free 1 888 596 4537 www panoramadtv com sales panor...

Страница 18: ...usly to achieve a AMBER tally indication in the LED Note that tally channel 1 pins 2 15 3 is used to drive the Tally Display 1 LEDs while tally channel 3 pins 8 21 9 is used to drive the Tally Display 2 LEDs See the diagram below for tally connector pinouts and LED wiring Three examples of tally connection configurations are shown on the facing page You can operate the Tally Indication LEDs by num...

Страница 19: ...2 3W and MON2 3 6 8 User Manual P N 821525 Rev E Section 3 Technical Information Tally Control Connections Tally Connection Configuration Examples Note In the examples above note that only channels 1 3 are available for hookup in the MON3 3 units ...

Страница 20: ...bol silk screened on the circuit board Insert the flat ribbon into the rear horizontal flat ribbon connector on the MSDI 4 board InserttheflatribboncabletothefrontLCDintotheinboard vertical flatribbonconnectorontheMSDI 4board Attach the MSDI 4 to the rear panel using the supplied nuts Attachthepowerharnesstothe4pinheaderontheMSDI 4 TheREDwiresgotowardsthemarking 12V Double check all wiring and con...

Страница 21: ...izontal removal insertion Cut termination resistor from rear main board at the point labeled B Input Cutout Note this is to allow HI Z 75 ohm termination selection from the MAV 1 board Installtheflatribbonconnectorsuppliedwiththeinterfaceintotheconnectortheribbonwasdisconnectedfrom in step 4 Insert the flat ribbon into the rear horizontal flat ribbon connector labeled J3 on the MAV 1 board Insert ...

Страница 22: ...RAMAdtv 31055 HuntwoodAvenue Hayward CA 94544 1 888 596 4537 Fax 510 870 0811 web www panoramadtv com e mail sales panoramadtv com Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510 870 0810 Fax 510 870 0811 US Toll Free 1 888 596 4537 www panoramadtv com sales panoramadtv com ...

Отзывы: