BA_PH_690-200_EN_11-22.docx
64
20.5.7
Setting Degrees & Intermediate Degrees
•
Loosen the clamping lever (
1
).
•
Then turn the cross-cut fence (
L
) and set to the desired angle via the digital display.
•
Tighten the clamping lever (
1
) again.
20.5.8
Changing Parameters of the Digital Indicator
•
Press button until parameter
“
AUFL
”
appears.
•
Press button to scroll through the parameters until the parameter to be changed appears.
•
Using the arrow keys, enter the parameters according to the parameter table
(see below) and confirm by pressing button .
•
Press a total of 15 times until the parameters have been exited.
•
Switch the unit off and on again so that the changes are applied!
Display
Designation / Value Range
Basic Setting
PANHANS Setting
AufL
Resolution (mm, In = Inch)
1, 0.1, 0.05, In 0.01, In 0.001, FrEI, 1/16in, 1/32in, 1/64in
0.1
FrEI
FAc
Multiplicator (only with resolution
“
FrEI
”
)
0.0000 ... 9.99999
0.00000
Standard 0.57160
dP
Decimal places (only with resolution
“
FrEI
”
)
0 … 0.000
0.00
0.00
rEF
Reference value
−99999 … (+)99999
00000.0
oFS
Offsettwert
−99999 … (+)99999
00000.0
ZAEhL
Counting direction
UP, DOWN
UP
Auto
Switch-off type
OFF, ON
OFF
OFF
PEriod
Switch-off time (in hours)
(only with switch-off type = ON)
0.2, 0.5, 1.0, 2.0, 4.0, 8.0
0.2
ISP
Actual value memory
ON, OFF
OFF
OFF
4_off
Switch off delay
ON, OFF
OFF
OFF
F_ABS
Enable reset function
ON, OFF
ON
ON
F_REL
Enable incremental mode
ON, OFF
OFF
OFF
F_REF
Enable change of reference value
ON, OFF
OFF
OFF
F_OFS
Enable change of offset value
ON, OFF
OFF
OFF
SPR
Language (D = German / E = English)
D
D
More details about the unit on
https://www.siko-global.com/en-de/service-downloads/download-products?A=detail&id=1440
For mitre cuts, the cross-cut fence (L) must always rest on the support rail (5) .