Panduit VeriSafe AVT Скачать руководство пользователя страница 1

 

VeriSafe AVT 

 

B21075 

Rev: 00  04-2018 

Absence of Voltage Tester 

Instruction Manual 

Models: VS-AVT2-C02L03, VS-AVT2-C08L10 

For use in Hazardous Locations Class I, Division 2 or equivalent Class I, Zone 2 

© Panduit Corp. 2018 

 

Original Instructions 

 

 

 

 

 

TO REDUCE THE RISK OF INJURY, USER 
MUST READ INSTRUCTION MANUAL 

 

 

 

NOTE: In the interest of higher quality and value, Panduit products are 
continually being improved and updated. Consequently, pictures may vary from 
the enclosed product.  

 

NOTE: Updates to this Instruction Manual may be available. Check 
www.panduit.com for the latest version of this manual. 
 

Email: 

[email protected] 

 

EU Website: 

www.panduit.com/emea 

 

EU Email:  

emeatoolservicecenter 

@panduit.com

 

 

www.panduit.com 

Technical Support: 

Tel:  1-866-405-6654 

 
 

Panduit Europe •  EMEA Service Center 

Almelo, Netherlands 

Tel: +31-546-580-452  •  Fax: +31-546-580-441 

The VeriSafe Absence of Voltage Tester is a permanently-mounted tester that is used to verify a circuit is de-
energized prior to opening an electrical enclosure. Once installed, a push of a button enables qualified electrical 
workers to verify the absence of voltage and see an active indication when the absence of voltage is confirmed. 
The Indicator Module is designed for a 30-mm notched panel knockout and the Isolation Module can be mounted 
to DIN rail or surface mounted using screws. 

Содержание VeriSafe AVT

Страница 1: ...version of this manual Email techsupport panduit com EU Website www panduit com emea EU Email emeatoolservicecenter panduit com www panduit com Technical Support Tel 1 866 405 6654 Panduit Europe EMEA...

Страница 2: ...ts 4 Output Contacts 4 Technical Specifications 5 Dimensions 7 Schematics 8 Installation Considerations 11 Installation Instructions 13 Commissioning Checklist 15 Operating Instructions 16 Troubleshoo...

Страница 3: ...mble or heat above 85 C incinerate or expose contents to water Use only the included AVT System Cable or approved replacement cables to connect the Isolation Module and Indicator Module Do not use a s...

Страница 4: ...recharger d monter ou chauffer au dessus de 85 C incin rer ou exposer le contenu l eau Utilisez uniquement le c ble syst me AVT inclus ou les c bles de remplacement approuv s pour connecter le module...

Страница 5: ...solation Module The outputs are normally open and close only when the green Absence of Voltage Indicator is illuminated By wiring to these contacts the AVT can be used as an input to a control system...

Страница 6: ...ements for safety related systems and for equipment intended to perform safety related functions functional safety General industrial applications including corrigendum 1 EN 55011 CISPR 11 Industrial...

Страница 7: ...tection specified is related to the Indicator Module only To meet the TYPE UL NEMA and CSA 1 12 4 4X 13 IP66 or IP67 requirements mount on a flat surface of an enclosure meeting the appropriate UL TYP...

Страница 8: ...4 2018 Dimensions Isolation Module Indicator Module Panel Knockout Units inches mm The Indicator Module is designed for use with a standard 30 mm knockout with notch The notch should be positioned on...

Страница 9: ...y or death Sensor leads of the same color should be terminated on the same conductor Each conductor should have at least one sensor lead set as shown on the schematic diagrams If a Sensor Lead separat...

Страница 10: ...MANUAL VeriSafe AVT B21075_00 Page 9 of 20 04 2018 Single Phase 2 Wire PE Single Phase 2 Wire PE Redundant Detection Lead Single Phase 3 Wire PE Corner Grounded DELTA 3 Wire PE High Leg DELTA 3 Wire...

Страница 11: ...Panduit Corp 2018 INSTRUCTION MANUAL VeriSafe AVT B21075_00 Page 10 of 20 04 2018 DC System 2 Wire PE Redundant Detection Lead...

Страница 12: ...AVT is suitable for use on circuits delivering up to 300 000 rms symmetrical A at 600 V Use of Overcurrent Protection Installation of an AVT with overcurrent protection is neither required nor recomm...

Страница 13: ...d pass This would be a multi fault scenario but is possible if terminations are not made properly and secured An AVT installed on a single phase system might only have one Detection Lead terminated to...

Страница 14: ...terminated properly and secured to the power conductor or other nearby rigid feature to prevent movement if the termination fails to remain intact Devices must be installed in an enclosure where the i...

Страница 15: ...r leads with a splice Use approved connection methods and follow local codes and standards when terminating the sensor leads Secure the sensor leads to the conductors to prevent the leads from contact...

Страница 16: ...label Verify that the label is placed near the isolation module and marked to indicate where the AVT is installed Record changes to panel documentation Close panel and secure doors covers Press the T...

Страница 17: ...of voltage push the Test Button A B Absence of Voltage Test Each time the Test Button is engaged the absence of voltage test sequence will be activated The test sequence includes running a self check...

Страница 18: ...test 2 Voltage detected above the threshold Warning This indicates that the enclosure is energized Follow safety procedures and use the appropriate PPE when investigating the source of voltage If pan...

Страница 19: ...the area is known to be non hazardous Battery Replacement Follow these steps to replace the battery Table 1 provides a list of batteries approved for use with the AVT Do not discard the battery in th...

Страница 20: ...alkaline cleaners Do not leave cleaners on the device for a long period rinse immediately Do not apply cleaners in direct sunlight or elevated temperatures The section of the VeriSafe Indicator Module...

Страница 21: ...t to Buyer whichever is longer 4 No Warranty for Third Party Products Panduit makes no representations and disclaims all warranties of any kind express or implied relative to any third party product o...

Отзывы: