© Panduit Corp. 2013
OPERATION MANUAL
PAT1M, PAT1.5M, PDM
ENGLISH
Page: 37 of 39
12: "ERROR MESSAGE” ADDENDUM
PDM DISPENSER
PHM HOSE
PAT1M TOOL
Error Message
Corrective Action
Tie in Tool
a.
Remove cable tie and continue
b.
If this happens often, change hose ends
c.
If problem persists after changing hose end, contact
Maintenance Department
Out of ties, or Tie in Dispenser
a.
Press “Buzzer” button, then “Continue” button
b.
If Out of Ties, get a new reel and load
c.
If not out of ties, press “Load” button once and continue
d.
If problem persists, contact Maintenance
Tie in Hose - Press “Air Burst”
a.
Press “Buzzer” button, then “Air Burst” button, remove
cable tie from jaws of tool. Press “Menu” button, Press
“Reset Load” button, Press “Load” button once, and
continue.
b.
If problem persists, contact Maintenance Department
Blocked or Dirty Tool Sensor, or
Tie Stuck in Tool Sensor
a.
Press “Buzzer” button, then “Air Burst” button, remove
cable tie from jaws of tool. Press “Menu” button, Press
“Reset Load” button, Press “Load” button once, and
continue.
b.
If cable tie is difficult to remove, contact Maintenance
Department. (Note: Tool damage may occur by trying to
pry out cable tie to remove.)
Blocked or Dirty Exit Sensor, or
Tie Stuck in Exit Sensor
a.
Press “Buzzer” button, then “Air Burst” button, remove
cable tie from jaws of tool. Press “Menu” button, Press
“Reset Load” button, Press “Load” button once, and
continue.
b.
If cable tie doesn’t come out, remove Hose from
Dispenser. Remove cable tie sticking out of Dispenser by
pulling lightly on it. Press “Menu” button, Press “Reset
Load” button, Press “Load” button once, and continue.
c.
If cable tie is stuck (don’t pull on it with pliers); or if no
cable tie is present, contact Maintenance Department.