Fusion Splicer
Type-Q101-M12
(T-71M12)
Fiber Cleaver
FC-6RM etc.
Jacket
remover
JR-6
Fiber Holder
FHM-12
(For 12c Fiber)
Fiber Holder
FHM-8
(For 8c Fiber)
SMF : G.652, G.657
MMF : MM50(OM2), MM50(OM3), MM50(OM4)
The Lynx-CustomFit® Splice-On Connector is designed and
manufactured to assure personal safety. Improper opera
�
on
can result in bodily injury and serious damage to this product.
Please read and observe all warnings instruc
�on
s given in this
opera
�
on manual.
Wear safety glasses
to protect your eyes when
handling op
�
cal
fi
ber.
Never look into
the end of a microscope or op
�
cal
cable connected to an
op�
cal output device that is
opera
�
ng. Laser radia
�
on is invisible, and direct
exposure can severely injure the human eye.
Alcohol is
flammab
le
, causes irrita
�
on and is harmful
if swallowed or inhaled. Keep alcohol away from
heat, sparks, skin, and avoid contact with eyes.
!
!
!
1. Improper assembly will result in a loss of performance.
Please read instruc
�
ons
given in this opera
�o
n manual
and the opera
�on
manual of the fusion splicer.
2.
Never touch the
fi
ber of the stub
. It has been inspected
in the factory.
3. The product is sensi
�ve
to dirt or dust. Do not take out
any parts from the package
un
�
l it is to be used
.
4. The characteris
�
c will be in
fl
uenced by the
fi
ber
cleaved surface condi
�
on. Please use a cleaver which
has a good cleaving characteris
�
c.
5. Do not remove the dust cap
un
�
l the connector has
been completely assembled
in order not to cause an
high inser
�
on loss due to them.
For your safety opera
�
on
Precau
�
ons
Compo
si�
on
Disposable
Holder (*1)
Dust Cap
Front
Housing
w/Spring
Rear
Stopper
MT STUB
Boot
Protec
�
on
Sleeve
(*1) 1 pc / 100 connectors
Assembling Tools
Recommended Program
Splicer
Fiber
Splicing Program
Heater Program
Type-Q101-M12
(T-71M12)
SMF 12c
SM12c
Lynx MPO
SMF 8c
SM8c
MMF 12c MM12c
MMF 8c
MM8c
Please perform Arc test prior to the splicing opera
�
on.
(See the opera
�
on manual of the splicer.)
*Ribbon
fib
er for tes
�ng
is included in the connector kit.
Please check
fib
er type inside the
fi
eld
fib
er.
Below equipment and tools are strongly recommended.
Dummy Cap
w/ Tether
Polish Surface and Housing Color
Rear Parts
SM Low Loss
SM Std. Loss
MM5010GOM3
8 degree Polish
Flat Polish
Yellow
Green
Aqua
MPO Splice-On Connector for Bare Ribbon
For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2019
FS148
Page 1 of 5
MPO Splice-On Conector for Bare Ribbon and 3mm
Round Fiber Installation Instruction