background image

AT-OME-RX21

25

Appendix

Specifications

Video

HDMI

2.0

HDCP

2.2

UHD/HD/SD

4096x2160@60

2

/50/30/25/24Hz, 3840×2160@60

2

/50/30/25/24Hz, 1080p@60/5

9.9/50/30/29.97/25/24/23.98Hz, 1080i@30/29.97/25Hz, 720p@60/59.94/50Hz, 

576p@50Hz, 576i@25Hz, 480p@60/59.96Hz, 480i@30Hz

VESA

2560×1600, 2048×1536, 1920×1200, 1680×1050, 1600×1200, 1440×900, 

1400×1050, 1280×1024, 1280×800, 1366×768, 1360×768, 1152×864, 1024×768, 

800×600, 640×480

Scaler Up/Down

1024x768p60, 1280x720p50, 1280x720p60, 1280x768p60, 1280x800p60, 

1360x768p60, 1600x1200p60, 1920x1080p24, 1920x1080p25, 1920x1080p50, 

1920x1080p60, 1920x1200p60, 2048x1080p60, 3840x2160p24, 3840x2160p25, 

3840x2160p30, 3840x2160p50, 3840x2160p60, 4096x2160p24, 4096x2160p25, 

4096x2160p30, 4096x2160p50, 4096x2160p60

Color Space

YUV, RGB

Chroma Subsampling

4:4:4, 4:2:2, 4:2:0

Color Depth

8-bit, 10-bit, 12-bit

Audio

HDMI Pass-Through Formats

PCM 2.0, LPCM 5.1, LPCM 7.1, Dolby® Digital, Dolby Digital Plus™, Dolby 

TrueHD, Dolby Atmos®, DTS® Digital Surround™, DTS-HD Master Audio™, and 

DTS:X®

Bit Rate

24 Mbits/s max

Analog Audio

   Format

Stereo 2-Channel

   Balanced Output

+4 dBu nominal gain, +20 dB headroom

   Frequency Response

20 Hz to 20 kHz, ± 0.5 dB

   Impedance

150 Ω

   Stereo channel separation

> 90 dB

   THD+N

< 0.03% at 20 Hz to 20 kHz

   SNR

> 90 dB at 1 kHz, zero clipping @ 0 dBFS, unweighted

   EQ

5 band, 63Hz, 85Hz, 250Hz, 1kHz, 4kHz

Sample Rate

32 kHz, 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz, 192 kHz

USB

Signal

2.0

Type A - Power

2.5 W per port

Maximum Data Rate

120 Mbps

Содержание Atlona Omega AT-OME-RX21

Страница 1: ...AtlonaManuals Scaler Receiver AT OME RX21 4K UHD Scaler for HDBaseT and HDMI...

Страница 2: ...AT OME RX21 2 Version Release Date Notes 1 Sept 2019 Release Version Information...

Страница 3: ...s voluntary and failure to register will not affect the product warranty To register your product go to http www atlona com registration Sales Marketing and Customer Support Welcome to Atlona Operatin...

Страница 4: ...purchase date for hardware electronics products purchased on or after June 1 2013 3 years from proof of purchase date for hardware electronics products purchased before June 1 2013 Lifetime Limited P...

Страница 5: ...s or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or excl...

Страница 6: ...Do not use this product near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install or place this prod...

Страница 7: ...9 Installation 10 Captive Screw Connections 10 Mounting Instructions 11 Connection Instructions 12 IP Modes 13 Connection Diagram 13 WebGUI 14 Video Settings 15 Audio 17 Display 18 RS 232 20 EDID 21...

Страница 8: ...nd value for 4K presentations The OME RX21 can remotely power an Atlona HDBaseT transmitter through Power over Ethernet PoE For additional integration convenience the OME RX21 features audio de embedd...

Страница 9: ...IP mode between DHCP and Static IP modes The LED will blink 2 times for DHCP and 3 times for static IP 9 HDBaseT IN Connect a compatible HDBaseT transmitter to this port 10 AUDIO OUT Connect to an aud...

Страница 10: ...und A dual low voltage signal relay is built into the OME RX21 for control of devices such as electric screens and display lifts A 3 pin captive screw connector has been included for connection When u...

Страница 11: ...f the unit AT OME SR21 OUTPUT LAN DC 24V RELAY C1 COM C2 HDBaseT IN L R 1 IP MODE RESET RS 232 1 2 RX RX TX TX 2 AT OME SR21 OMEGA TM PWR LINK HOST USB HDMI IN USB HUB OMEGA TM INPUT PATTERN DEVICE IP...

Страница 12: ...rol devices such as electric screens and display lifts connect the device to the 3 pin captive screw relay port 9 Connect the included DC 24V power supply to the power port 10 Connect the included IEC...

Страница 13: ...a Network LAN it will automatically be assigned an IP address by the DHCP server if available Press the DEVICE IP button to show the IP address in the top left corner of the display Connection Diagram...

Страница 14: ...OME RX21 and the network 2 Press the DEVICE IP button on the front panel to display the IP address of the unit in the top left corner of the connected display 3 Launch a web browser and enter the IP a...

Страница 15: ...HDCP to switch between compliant and non compliant according to the source and display HDCP handshake status Off Sets the HDBaseT or HDMI port to HDCP non compliant No HDCP compliant source signals wi...

Страница 16: ...60p60 4096x2160p24 4096x2160p25 4096x2160p30 4096x2160p50 4096x2160p60 Aspect Ratio Select between Keep which will keep the aspect ration of the source device and Fill which will adjust the picture to...

Страница 17: ...DMI L R Disable Mutes the audio output signal of the ports No audio will pass when selected Output Volume Volume bar Adjusts the master volume output of the unit from 80 to 0 Default is 0 EQ Level Lev...

Страница 18: ...ommand to the output when signal is no longer received for the set auto power off time Lamp cool down timer Sets the time between when the display is turned off and when the next command can be sent D...

Страница 19: ...urrent display is not found within the database use generic and manually adjust the command fields Repeat Command Enable Status to repeat the commands Default repeat number is 2 and can be adjusted fr...

Страница 20: ...RS232 2 Select the baud rate data bit parity and stop bit to match the display s parameters Defaults are 115200 8 None and 1 HDBaseT Select the baud rate data bit parity and stop bit to match the tra...

Страница 21: ...om the drop down menu Once output 1 is selected press the save button to make it available in the EDID settings drop down menus Users Admin Password Update the admin password for the switcher Only the...

Страница 22: ...ojection screen it allows for two different circuits to be controlled up and down pictured to the right The relay will default to follow the display When the unit turns on the relay will close C1 and...

Страница 23: ...ode Toggle telnet login mode on and off If on a username and password will be required to control the unit via telnet Telnet Timeout Set the amount of time between actions before the current user is l...

Страница 24: ...stops TX RX Version When the test starts the chipset version will display AT OME RX21 will be VS2310 TMDS Clock After the test has been initiated it will display the TMDS clock frequenzy in Mhz Cable...

Страница 25: ...2160p30 3840x2160p50 3840x2160p60 4096x2160p24 4096x2160p25 4096x2160p30 4096x2160p50 4096x2160p60 Color Space YUV RGB Chroma Subsampling 4 4 4 4 2 2 4 2 0 Color Depth 8 bit 10 bit 12 bit Audio HDMI P...

Страница 26: ...3 pin captive screw RS 232 2 3 pin captive screw bidirectional LAN 2 RJ45 100Base T DC 24V 1 4 pin mini DIN locking connector PWR indicator 1 LED green LINK indicator 1 LED yellow Control Buttons DEVI...

Страница 27: ...AT OME RX21 27 Appendix Certification Device CE FCC UL...

Страница 28: ...names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change without notice Actual products product images and o...

Отзывы: