Panduit Atlona AT-OCS-900N Скачать руководство пользователя страница 6

AT-OCS-900N

6

1.  Read these instructions.

2.  Keep these instructions.

3.  Heed all warnings.

4.  Follow all instructions.

5.  Do not use this product near water.

6.  Clean only with a dry cloth.

7.  Do not block any ventilation openings. Install in 

accordance with the manufacturer’s instructions.

8. 

Do not install or place this product near any heat 

sources such as radiators, heat registers, stoves, or 

other apparatus (including amplifiers) that produce 

heat.

9.  Do not defeat the safety purpose of a polarized 

or grounding-type plug. A polarized plug has two 

blades with one wider than the other. A grounding 

type plug has two blades and a third grounding 

prong. The wide blade or the third prong are 

provided for your safety. If the provided plug does 

not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.  Protect the power cord from being walked on 

or pinched particularly at plugs, convenience 

receptacles, and the point where they exit from the 

product.

11. 

Only use attachments/accessories specified by 

Atlona.

12.  To reduce the risk of electric shock and/or damage 

to this product, never handle or touch this unit or 

power cord if your hands are wet or damp. Do not 

expose this product to rain or moisture.

13.  Unplug this product during lightning storms or when 

unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. 

Servicing is required when the product has been 

damaged in any way, such as power-supply cord or 

plug is damaged, liquid has been spilled or objects 

have fallen into the product, the product has been 

exposed to rain or moisture, does not operate 

normally, or has been dropped.

CAUTION: TO REDUCT THE RISK OF

ELECTRIC SHOCK

DO NOT OPEN ENCLOSURE OR EXPOSE

TO RAIN OR MOISTURE.

NO USER-SERVICEABLE PARTS

INSIDE REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The exclamation point within an equilateral triangle is intended to alert the user to 

the presence of important operating and maintenance instructions in the literature 

accompanying the product.

The information bubble is intended to alert the user to helpful or optional opera-

tional instructions in the literature accompanying the product.

Safety and Certification

FCC Compliance

FCC Compliance and Advisory Statement: This hardware device complies with Part 15 of the FCC rules. Operation is subject to the following two 

conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received including interference that 

may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed or used in accordance with the instructions, may cause 

harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures: 1) reorient or relocate the receiving antenna; 2) increase 

the separation between the equipment and the receiver; 3) connect the equipment to an outlet on a circuit different from that to which the receiver 

is connected; 4) consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the 

party responsible for compliance could void the user’s authority to operate the equipment. Where shielded interface cables have been provided 

with the product or specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be 

used in order to ensure compliance with FCC regulations.

Copyright, Trademark, and Registration

© 2021 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. Pricing, specifications and availability 

subject to change without notice. Actual products, product images, and online product images may vary from images shown here. 

All other trademark(s), copyright(s), and registered technologies mentioned in this document are the properties of their respective owner(s).

Содержание Atlona AT-OCS-900N

Страница 1: ...AtlonaManuals Automation AT OCS 900N Network Enabled Occupancy Sensor...

Страница 2: ...or higher must be used in order to integrate the OCS with Velocity Changed Interfacing with Velocity section to Integration with Velocity 3 Nov 2021 Replaced wiring diagram with diagram used on web A...

Страница 3: ...08 962 0515 US International Sales and Customer Service Hours Monday Friday 6 00 a m 4 30 p m PST http atlona com International Headquarters Atlona International AG To distrasse 18 8002 Zu rich Switze...

Страница 4: ...purchase by the end purchaser The date contained on the end purchaser s sales or delivery receipt is the proof purchase date Limited Product Warranty Terms New Products 3 year limited product warranty...

Страница 5: ...responsible for the direct special incidental or consequential damages resulting from any breach of warranty or condition or under any other legal theory Some countries districts or states do not allo...

Страница 6: ...era tional instructions in the literature accompanying the product Safety and Certification FCC Compliance FCC Compliance and Advisory Statement This hardware device complies with Part 15 of the FCC r...

Страница 7: ...s 22 Saving Configuration Files 22 Uploading Configuration Files 22 Resetting the AT OCS 900N 23 Using the Web Server 23 Using the Hardware Reset Button 23 Rebooting the AT OCS 900N 24 Configuring the...

Страница 8: ...n standard design allows sensor information to be communicated to third party ventilation lighting and other systems over TCP IP using common protocols such as UDP TCP WebSocket and MQTT Introduction...

Страница 9: ...coming light and directs the light to the infrared sensor 2 LED indicators These indicators provide lens illumination for device functionality and testing These LED indicators can be changed to differ...

Страница 10: ...return to the down position securing the unit in place C E I L I N G C E I L I N G Energy Mgmt Equip Motion Sensor Low Bay White Connect to LPS supply only Input 57V 1 4W Max Amb 50 C S N 210226 IDLM...

Страница 11: ...5 m 20 ft 6 1 m 15 ft 4 6 m 10 ft 3 0 m 5 ft 1 5 m 0 20 ft 6 1 m 30 ft 9 1 m 40 ft 12 2 m 40 ft 12 2 m 30 ft 9 1 m 20 ft 6 1 m 10 ft 3 0 m 0 10 ft 3 0 m 20 ft 6 1 m 30 ft 9 1 m 40 ft 12 2 m 0 The AT O...

Страница 12: ...Once the removed the wing clips will return to their normal position 4 Disconnect the Ethernet cable from the LAN port Removal Instructions The AT OCS 900N can be easily removed if necessary Refer to...

Страница 13: ...AT OCS 900N 13 Installation Connection Diagram...

Страница 14: ...e in the Username field In the example above the username admin is used 4 Enter the desired password in the Password field IMPORTANT Both the username and password must be 5 16 characters in length Al...

Страница 15: ...s of the AT OCS 900N in the address bar 2 Enter the correct username and password in the respective fields 3 Click the Login button Logging in after registration 4 The Dashboard page will be displayed...

Страница 16: ...this box click to remove the check mark This will disable DHCP and provide the option to specify a static IP address 5 Enter the desired address in the IP Address field Also enter the required informa...

Страница 17: ...address from a DHCP server Using DHCP to assign an IP address The AT OCS 900N is shipped with DHCP enabled Once connected to a network the DHCP server if available will automatically assign an IP add...

Страница 18: ...is enabled Uncheck this box to disable TLS Using Transport Layer Security TLS The AT OCS 900N provides Transport Layer Security TLS for added communication security over a non secure network TLS is e...

Страница 19: ...he MAC address However the host name can be changed to a more recognizable identifier 1 Open the desired web browser and enter the IP address of the AT OCS 900N 2 Login using the required credentials...

Страница 20: ...ogin using the required credentials 3 Click User in the side menu bar 4 In the Username field enter the desired user name 5 In the New Password field enter the desired password Log Out button NOTE Bot...

Страница 21: ...mation will be displayed under the Dashboard menu 1 Open the desired web browser and enter the IP address of the AT OCS 900N 2 Login using the required credentials 3 Click System in the side menu bar...

Страница 22: ...ate the Configure Settings window group and click the Download button 1 Follow steps 1 3 above 2 Locate the Configure Settings window group and click the Choose File button 3 The Open dialog will be d...

Страница 23: ...the web server is not available the AT OCS 900N provides a reset button on the unit 1 Open the desired web browser and enter the IP address of the AT OCS 900N 2 Login using the required credentials 3...

Страница 24: ...ed without losing any settings Following the procedure below 1 Open the desired web browser and enter the IP address of the AT OCS 900N 2 Login using the required credentials 3 Click System in the sid...

Страница 25: ...d credentials 3 Click Sensors in the side menu bar 4 Locate the Motion Sensors window group 5 In the Motion On Event field enter the period of continuous motion in seconds that is required before the...

Страница 26: ...center and three outer LED indicators as shown below Removing the lens cap will expose these LED indicators The color of each of these LED indicators can be changed to any color Note that when these...

Страница 27: ...es The valid range for each component is 0 to 255 If Hex is selected then the LED color will be represented by a singular hexadecimal value in the form of xxxxxx Valid range is 000000 to FFFFFF 7 Ente...

Страница 28: ...e menu bar 4 Locate the Ambient Light Sensor window group 5 Click the Sensitivity drop down list and select the desired setting For brighter environments set the sensitivity setting to a lower value F...

Страница 29: ...OCS 900N 2 Login using the required credentials 3 Click Sensors in the side menu bar 4 Locate the Ambient Temperature Sensor window group The current ambient temperature will be displayed 5 In the pro...

Страница 30: ...of a broker server and one or more clients For example in the Figure 1 2 the AT OCS 900N is connected to a LAN along with two other clients and a broker Client A and Client B will now subscribe to a...

Страница 31: ...enable the feature When enabled this toggle switch will be green 5 Under Connection Settings do the following a Enter the address of the broker in the Broker field b Enter the port number in the Port...

Страница 32: ...e message 2 Exactly once The highest level of service and guarantees that each message is received only once by the intended recipients The guarantee is provided by at least two request responses betw...

Страница 33: ...tions similar to the UDP protocol where there is no guarantee of delivery from the client to the broker The recipient does not acknowledge receipt of the message and the message is not stored and re t...

Страница 34: ...web server is launched for the first time Web Server First Time Registration page Username Enter the desired username in this field The username must be 5 16 characters in length and can be any combin...

Страница 35: ...terfaces This page is displayed when the IP address of the AT OCS 900N is entered in the address bar of a web browser Login page Username Enter the username in this field Password Enter the password i...

Страница 36: ...uct Hardware The hardware version Serial Number The serial number of the unit Firmware Version The version of firmware that the AT OCS 900N is running Always make sure to check the AT OCS 900N product...

Страница 37: ...it Gateway The default gateway router for the network Hostname The hostname of the unit MAC The Media Access Control MAC address of the AT OCS 900N DNS 1 DNS 2 The address of the DNS servers System In...

Страница 38: ...ed motion since the unit was powered on If there is constant motion being detected this clock will continue to run until movement is no longer detected Time format is in days hours minutes and seconds...

Страница 39: ...alues can be changed Refer to Setting the LED Color page 26 for more information UDP TCP WS MQTT Each of these toggle switches provide quick enabling disabling of these protocols If a protocol is enab...

Страница 40: ...seconds where continuous motion must be detected before the event is triggered Valid ranges are integers from 0 to 120 Motion Off Event Sets the time period in minutes where no motion must be detecte...

Страница 41: ...n RGB Uses RGB values to specify the motion state color Valid ranges for each RGB color component are 0 to 255 Hex Used hexadecimal values to specify the motion state color Valid range is 000000 to FF...

Страница 42: ...this drop down list to specify the sensitivity setting Valid ranges are 0 to 5 Events Sets the sensor communication threshold This is the minimum value required to trigger and event The communication...

Страница 43: ...le or disable subscription of the information in the row IP Address Port Motion Light Temp UDP Settings This section allows the sensor to process any incoming messages to port 9000 If UDP is disabled...

Страница 44: ...sable the feature When a feature is enable the checkbox will be checked Save Click this button to commit changes Save Click this button to commit changes TCP Settings Enabling TCP will allow the senso...

Страница 45: ...et to 0 zero then the keep alive mechanism is deactivated Clean Session When a client connects to a broker it can do so in one of two ways non persistent clean or persistent connection Check this box...

Страница 46: ...age is not stored and re transmitted by the sender 1 At least once Guarantees that a message is delivered at least once to the receiver The sender stores the message until it receives a PUBACK packet...

Страница 47: ...tting Description 0 At most once Guarantees a best effort delivery It functions similar to the UDP protocol where there is no guarantee of delivery from the client to the broker The recipient does not...

Страница 48: ...eld Refer to Changing the Hostname page 19 for more information Enable TLS Click this checkbox to enable or disable Transport Layer Security TLS This feature is enabled by default When enabled the che...

Страница 49: ...e changed when Enable DHCP is disabled Subnet Mask Enter the subnet mask in this field This field can only be changed when Enable DHCP is disabled Primary DNS Secondary DNS Enter the IP address of the...

Страница 50: ...ed Refer to Resetting Login Credentials page 20 for more information User Page Username Enter the desired user name in this field New Password Enter the desired password in this field Confirm New Pass...

Страница 51: ...evice Information page 21 for more information Location Enter the location of the AT OCS 900N in this field Save Click this button to commit changes Choose File Click this button to select the firmwar...

Страница 52: ...he desired json settings file to the AT OCS 900N Identify Device Click this button to identify the AT OCS 900N within the room During the identification procedure the LED indicators within the unit wi...

Страница 53: ...to Logging in to the Web Server page 14 3 Click System in the menu bar 4 Locate the Upgrade Firmware window group and click the Choose File button Requirements AT OCS 900N Firmware file Computer on th...

Страница 54: ...ser and enter the IP address of Velocity 2 Access the Configure Equipment window for the AT OCS 900N Refer to the Velocity User Manual if necessary 3 The following screen will be displayed Driver Conf...

Страница 55: ...box is checked then the room will be turned on when occupied When this feature is enabled a checkmark will appear in the box If the Turn room off when there is no motion box is checked then the room w...

Страница 56: ...Refer to the Velocity User Manual for more information on creating and using macros The AT OCS 900N sensors will report their current values and display them in this window as shown in the illustrati...

Страница 57: ...no E524557 UKCA Power Consumption 1 1 W PoE 802 3af Compliance NDAA 899 Yes Environmental Fahrenheit Celsius Operating 32 to 122 0 to 50 Storage 40 to 158 40 to 70 Humidity RH 90 maximum non condensin...

Страница 58: ...Toll free US International atlona com 877 536 3976 41 43 508 4321 35280 R6...

Отзывы: