43
User manual
car. It is necessary to configure an analog input (INP) as “Code immobilizer” in the settings of the base
unit inputs when implementing the “Code immobilizer” via an analog input. It may be necessary to
switch on the ignition after entering the level 11 of programming (if the car bus is active only when
the ignition is switched on) when implementing the “Code immobilizer” via digital car bus protocol.
After selecting active buttons enter the sublevel 11.2 (Entering the PIN-code) by one pressing of
the VALET button. Program PIN-code using selected buttons at this sublevel; press the VALET button
once and enter PIN-code again. To confirm PIN-code re-entering and save all the settings, press the
VALET button once again.
Sublevel 11.1 – Selecting buttons:
This sublevel is used to select active buttons via digital protocol of a car or via the “Code
Immobilizer” analog input. To determine the activity of the analog “Code Immobilizer” input, apply
potential to the corresponding input (INP) of the base unit, LED indicator will be flashing orange. If
you determine buttons via digital protocol, select one or more buttons (up to four) for entering the
secret code of the immobilizer. To do this press the selected button, LED indicator will confirm input
with orange flashes. If there are no orange flashes when any button is pressed, then this button is not
recognized by the system, select a different button. Repeat the procedure to select the second, third,
fourth button and enter the next sublevel. To enter the next sublevel press the VALET button once.
Sublevel 11.2 – Entering the PIN-code:
Program the immobilizer deactivation PIN-code using the selected button or buttons. Enter the
first digit by pressing the previously selected button (pauses between presses should not exceed 1
second). The base unit will confirm entering with a red flash of the LED indicator. Enter the second
(third, fourth) digit by pressing the previously selected button. The base unit will confirm entering of
each digit with red flash of the LED indicator.
Input the required number of digits (up to 4) and then press VALET button. The system will
confirm receiving of the secret validator code with long red flash of LED indicator and will wait for
confirmation of PIN-code.
Sublevel 11.3 - Confirmation of the PIN-code input:
Enter the PIN-code again similarly to the procedure (level 11.2 – Entering the PIN-code) and press
the VALET button. The system will confirm correct PIN-code with red and green flashes of the LED
indicator and will memorize the PIN-code, and then the system will proceed to the programming
mode awaiting level input. Incorrect confirmation is indicated with a long red flash of LED indicator,
after that the system will return to the programming mode.
Level 12 – Fuel level calibration
To control fuel level, make connection and configure the settings:
• Setting is performed via the Pandora Alarm Studio. The “Use INP to control fuel level” item should
be enabled in the settings, the factory setting of this input (input settings) must be unselected.
Содержание Light
Страница 52: ...52 Security service system Pandora Light...