• It is forbidden to cook food directly on the burner flame, or leave the burners without a cooking pot or
pan on them, as the flames and heat could be hazardous and could damage the appliance, something
that will not be covered by the guarantee. The use of the appliance over wood, coal, charcoal, etc.
cookers is not authorised.
• Any frying carried out under the hood must be constantly attended to avoid the oil or fat catching fire.
Do not flambé under the hood.
• Take care, accessible parts of the appliance could cause burns, as they can get hot while cooking.
• The minimum distance between the surface of the cooktop and the lower edge of the hood must be 65
cm if the extractor hood is fitted over gas cooker. If the installation instructions of the gas cooker
indicates a greater distance, this must be followed.
• Respect the frequency of cleaning and filter replacement specified. Excessive accumulation of grease
could give rise to fires. Never use the hood without the grease filter fitted. See section 9 on hood
maintenance, p. 28-36.
• Hood and conduit installation must comply with regulations on ventilation of closed spaces. More
specifically, the exhausted air must not be led through a conduit that is used for exhausting fumes from
other appliances using gas or other fuels (central heating installations, etc.).
NB! When the hood is in operation “in suction” at the same time as a heating system that depends
on ambient air (gas, oil, coal boiler, chimney, etc.), take special care to avoid the hood abosrbing air
needed for combustion, this could cause dangerous accumulations of carbon monoxide in the premises or
home, which could be deadly. If the extractor hood is installed together with a combustion appliance such
as a boiler, chimney or local heating, the manufacturers of these appliances must be contacted to ensure
optimum and risk-free operation.
• Negative pressure in the premises must not exceed 0.04 mbar. This will allow the hood to operate in
optimum conditions. To achieve this, it is necessary to have a permanent entry of fresh air to avoid air
stagnation, it is recommended to have a ventilation grille for this purpose. Doors and windows are not
enough.
• Electrical power supply must be stable and meet the electrical requirements of the appliance (see the
nameplate of the appliance). If the power supply is unstable, with variations in voltage, current, surges
and cuts, electrical storms, etc., the hood could malfunction and even be damaged, in which case repairs
will not be covered by the guarantee. If any of these things happen, disconnect the hood and contact an
electrician or your electrical company to solve the problem.
• Improper and unauthorised handling of the hood, as well as modifying, cutting or perforating the body,
structure, motor or wiring of the hood are expressly forbidden. In case of any of the above, the guarantee
will be automatically void and the manufacturer will not be held liable for any possible harm or damages.
1. SAFETY INSTRUCTIONS
Содержание E-297 V1000 ECO
Страница 15: ...C x4 5 E x4 6 A x1 INSTALACION INSTALLATION INSTALLATION INSTALACION INSTALLATION INSTALLATION ...
Страница 16: ...H x1 F x1 G x1 7 8 INSTALACION INSTALLATION INSTALLATION INSTALACION INSTALLATION INSTALLATION ...
Страница 18: ...B x4 10 D x4 Ø150mm INSTALACION INSTALLATION INSTALLATION ...
Страница 19: ...2 11 21 ANEXO 12 INSTALACION INSTALLATION INSTALLATION ...