END
3-12 Code 39 (Code 32, Trioptic Code 39)
Read:
Format
Start character(*)
Data digits (variable)
Check digit (optional)
End character(*)
Check digit verification: The check digit verification is optional.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Each symbol has own max./min. code length. If both setting of max./min. code
length a
re “00”s, the setting of global max./min. code length is
effective. The length is defined as to the
actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure
that the minimum length setting is no greater than the maximum length setting, otherwise all the labels of
the symbol will not be readable. In particular, you can see the same value for both minimum and maximum
reading length to force the fixed length barcode decoded. Refer to
3-5 Scan trigger mode &
some global settings
.
Code ID setting of
UPC-A
.
Code ID setting: Refer to
Insert group selection:
3-7
UPC-A
.
Start/End
transmission:
The start character and end character of Code 39
are “
*
”s. You can transmit all data digits including two “
*
”s.
“
*
” as data character: By setting Enable, “
*
” can be recognized as data character.
Convert Code 39 to Code 32: Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.
Note that Code 39 must be enabled in order for this parameter to function. Format of Code 32
“A” (optional)
Data digits (8 digits)
Check digit
Code 32 Prefix “A” transmission: By setting Enable, the prefix character “A” can be added to all Code 32
barcodes.
Trioptic Code 39 read: Trioptic Code 39 is a variant of Code 39 used in the marking of magnetic tapes
and computer cartridges. Trioptic Code 39 symbols always contain six characters. Format of Trioptic Code
39
Start character ($)
Data digits (6 digits)
End character ($)
Trioptic Code 39 Start/End transmission: The start character and end character of Trioptic Code 39 are
“$”s. You can transmit all data digits including two “$”s.
SETUP
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. value
Read
Disable
00
3-7
Refer to Insert group selection of
Содержание MD2000
Страница 1: ...MD2000 Laser Barcode Scanner User Manual Version MD2000_UM_EN_V1 1 5 ...
Страница 3: ...i ...
Страница 6: ...iv ...
Страница 16: ...10 Figure 2 9 DIS AutoDete EN AutoDete ...
Страница 24: ...18 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 END ...
Страница 69: ...63 END ...
Страница 79: ...73 6 Test chart A908765439 UPC A UPC E UPC E1 EAN 13 ISBN ISSN EAN 8 Code 39 Code 32 ...
Страница 84: ...78 To finish parameter setting please scan the bar code below ...