Function
Range
Resolution
Accuracy of the
value displayed in %
*)
AC current (A~)
6 A
0,001 A
±(2,5% + 8 digits)
60 A
0,01 A
100 A
0,1 A
DC current (A=)
6 A
0,001 A
±(3,0% + 8 digits)
60 A
0,01 A
100 A
0,1 A
AC voltage (V~)
600 V
0,1 V
±(0,8% + 5 digits)
DC voltage (V=)
600 V
0,1 V
±(0,5% + 3 digits
Frequency (Hz)
60 Hz
0,01 Hz
±(1,0% + 5 digits)
1000 Hz
1 Hz
Resistance (Ω)
6 k
0,001 k
±(0,8% + 3 digits)
*) In order to obtain the accuracy, the unit should be calibrated 1 x yearly
under operating conditions (18 °C - 28 °C).
8.
Operating Instructions
Always switch OFF the device when it is not in use.
Be aware of the Safety Instructions (Chapter 3)
Please refer to the sketches on the first pages of this manual.
Attention!
Hazardous voltage! The probes may not be long enough to touch the hot
parts in some 230V wall sockets as they are deep inside. As a result, the
reading can show 0 volts. Make sure that the probes touch the metallic
contacts in the socket before assuming that voltage has not been applied.